Development and validation of an assay for the measurement of gentamicin concentrations in dried blood spots using UHPLC-MS/MS

被引:6
|
作者
Anibaletto dos Santos, Ana Laura [1 ,2 ]
Cezimbra da Silva, Anne Caroline [1 ,2 ]
Feltraco Lizot, Lilian de Lima [1 ,2 ]
Schneider, Anelise [2 ]
Meireles, Yasmin Fazenda [2 ]
Hahn, Roberta Zilles [1 ]
Pagnussat, Lidiane Riva [4 ]
Nonnenmacher, Julia Livia [5 ]
Hahn, Siomara Regina [3 ]
Linden, Rafael [1 ,2 ]
机构
[1] Univ Feevale, Analyt Toxicol Lab, Novo Hamburgo, RS, Brazil
[2] Univ Feevale, Grad Program Toxicol & Analyt Toxicol, Novo Hamburgo, Brazil
[3] Univ Passo Fundo, Coll Pharm, Passo Fundo, RS, Brazil
[4] Hosp Sao Vicente Paulo, Passo Fundo, RS, Brazil
[5] Univ Passo Fundo, Multidisciplinary Residency Program, Passo Fundo, RS, Brazil
关键词
Gentamicin; UHPLC-MS/MS; Dried blood spots; Therapeutic drug monitoring; Neonates; MASS-SPECTROMETRY; LC-MS/MS; HEMATOCRIT; TIME;
D O I
10.1016/j.jpba.2021.114448
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gentamicin sulfate (GEN) is an aminoglycoside antibiotic with a narrow therapeutic range of plasma concentrations. The collection of venous blood represents a significant burden for patients, especially in neonatology. Dried blood spots (DBS) obtained from capillary blood can be an alternative for drug measurements in this particular population. This study aimed to develop and validate an assay for the quantification of GEN in DBS using UHPLC-MS/MS. Total GEN concentrations were obtained by adding the individual concentrations of the GEN forms C1, C1a, and C2. The assay used a DBS disk containing approximately 17 mu L of blood for GEN quantitation in the range of 0.1-40 mg L-1. Measurement accuracy for total GEN was in the range of 102.6-108.6%, inter-assay precision was 11.3-13.1% and intra-assay precision was 9.1-12.8.% GEN was stable for 21 days at - 20 and 8 degrees C, but only for 24 h at room temperature. Blood Hct affected the accuracy within acceptable limits (93.8-95% at Hct% of 30, 104.3-113% at Hct% of 50). Blood spotted volume did not affect GEN measurement accuracy. Concentrations of GEN in DBS obtained after heel pricks were correlated to plasma levels in a small cohort of neonatal patients. However, percentual differences between estimated plasma concentrations and actual plasma levels presented values between - 64-35.3% (average difference of - 1.9%). The use of DBS for the measurement of GEN concentrations can increase access to TDM of this antibiotic due to the ease of sample collection and the facilitated specimen transportation logistics when testing is not available onsite. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Development and Validation of a Dried Blood Spot Assay Using UHPLC-MS/MS to Identify and Quantify 12 Antihypertensive Drugs and 4 Active Metabolites: Clinical Needs and Analytical Limitations
    Peeters, Laura E. J.
    Bahmany, Soma
    Dekker, Tim
    Aliawi, Aya
    van Domburg, Bart
    Versmissen, Jorie
    Koch, Birgit C. P.
    THERAPEUTIC DRUG MONITORING, 2022, 44 (04) : 568 - 577
  • [12] Method development and validation for acrylamide in potato cutlet by UHPLC-MS/MS
    Kumari, Alka
    Bhattacharya, Bhaswati
    Agarwal, Tripti
    Paul, Vijay
    Maurya, Vaibhav Kumar
    Chakkaravarthi, S.
    Simal-Gandara, J.
    FOOD CONTROL, 2023, 151
  • [13] A feasible protocol to profile bile acids in dried blood spots from rats using a UHPLC-MS/MS method combining a surrogate matrix
    Ma, Ziying
    Sheng, Ning
    Zhang, Jinlan
    ANALYST, 2023, 148 (20) : 5190 - 5202
  • [14] Development and validation of an LC-MS/MS assay for the quantitative analysis of alprazolam, ?-hydroxyalprazolam and hydrocodone in dried blood spots
    Abarca, Radek
    Gerona, Roy
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1220
  • [15] A UHPLC-MS/MS Method for Therapeutic Drug Monitoring of Aciclovir and Ganciclovir in Plasma and Dried Plasma Spots
    Pigliasco, Federica
    Cafaro, Alessia
    Simeoli, Raffaele
    Barco, Sebastiano
    Magnasco, Alberto
    Faraci, Maura
    Tripodi, Gino
    Goffredo, Bianca Maria
    Cangemi, Giuliana
    BIOMEDICINES, 2021, 9 (10)
  • [16] A Validated UHPLC-MS/MS Method to Quantify Eight Antibiotics in Quantitative Dried Blood Spots in Support of Pharmacokinetic Studies in Neonates
    Liu, Qian
    Liu, Lanyu
    Yuan, Yu
    Xie, Feifan
    ANTIBIOTICS-BASEL, 2023, 12 (02):
  • [17] Steroid profiling by UHPLC-MS/MS in dried blood spots collected from healthy women with and without testosterone gel administration
    Salamin, Olivier
    Nicoli, Raul
    Xu, Cheng
    Boccard, Julien
    Rudaz, Serge
    Pitteloud, Nelly
    Saugy, Martial
    Kuuranne, Tiia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 204
  • [18] Clinical validation and implementation of a multiplexed immunosuppressant assay in dried blood spots by LC-MS/MS
    Sadilkova, Katerina
    Busby, Barbara
    Dickerson, Jane A.
    Rutledge, Joe C.
    Jack, Rhona M.
    CLINICA CHIMICA ACTA, 2013, 421 : 152 - 156
  • [19] Development and validation of an UHPLC-MS/MS method for the determination of mycotoxins in grass silages
    McElhinney, Cormac
    O'Kiely, Padraig
    Elliott, Chris
    Danaher, Martin
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (12): : 2101 - 2112
  • [20] Development and Validation of a UHPLC-MS/MS Method for the Analysis of Fusarium Mycotoxins in Onion
    Ramo, Sari
    Haapalainen, Minna
    Latvala, Satu
    FOOD ANALYTICAL METHODS, 2021, 14 (08) : 1524 - 1536