Similar optimal distalization and lateralization angles can be achieved with different reverse shoulder arthroplasty implant designs

被引:3
|
作者
Marsalli, Michael [1 ]
Errazuriz, Juan De Dios [2 ]
Cartaya, Marco A. [2 ]
de la Paz, Joaquin [3 ]
Fritis, Diego N. [1 ,2 ]
Alsua, Pedro I. [2 ]
Moran, Nicolas I. [2 ,4 ]
Rojas, Jose T. [5 ]
机构
[1] Clin Univ Andes, Dept Orthopaed & Trauma Surg, Shoulder & Elbow Surg Unit, Santiago, Chile
[2] Hosp Trabajador, Dept Orthopaed Surg, Shoulder Surg Unit, Providencia, Chile
[3] Hosp Trabajador, Dept Orthopaed Surg, Providencia, Chile
[4] Hosp Militar Santiago, Dept Orthopaed & Trauma Surg, Shoulder & Elbow Surg Unit, Santiago, Chile
[5] Hosp San Jose, Dept Orthopaed Surg, Shoulder & Elbow Surg Unit, Santiago, Chile
关键词
Reverse shoulder arthroplasty; Distalization shoulder angle; Lateralization shoulder angle; Rotator cuff arthropathy; Shoulder arthroplasty; Rotator cuff; CUFF; PROSTHESIS; ROTATION; MOTION;
D O I
10.1016/j.jor.2021.10.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Optimal postoperative distalization (DSA) and lateralization (LSA) shoulder angles have been described as radiological measurements correlated with function after reverse shoulder arthroplasty (RSA). The proposed optimal values are DSA between 40 degrees and 65 degrees and LSA between 75 degrees and 95 degrees; however, whether these values can be reached with different implant designs is unclear. Aim: To determine which RSA implant could achieve higher rates of optimal DSA and LSA, to determine any association between each implant and optimal DSA and LSA, and to assess the correlation of the preoperative critical shoulder angle (CSA) and acromial index (AI) with the DSA and LSA. Methods: This was a retrospective comparative study of all patients who underwent primary RSA for rotator cuff arthropathy. Three RSA implant designs were included, based on which patients were divided into three groups: group 1 (FH Arrow (TM); 16 patients) comprised onlay implants with a 135 degrees neck-shaft angle (NSA); group 2 (Biomet Comprehensive (TM); 20 patients) comprised onlay implants with a 147 degrees NSA; group 3 (Mathys Affinis (TM); 15 patients) comprised inlay implants with a 155 degrees NSA. The AI and CSA were measured on preoperative ra-diographs. The DSA and LSA were measured on true AP postoperative radiographs. Results: The mean DSAs were 44 degrees, 46 degrees, and 46 degrees (P = 0.671) and the mean LSAs were 92 degrees, 91 degrees, and 82 degrees for groups 1, 2, and 3, respectively (P = 0.003). Group 3 had lower LSA than groups 1 (- 10 degrees; P = 0.005) and 2 (-9 degrees; P = 0.002). Optimal DSA and LSA were achieved in 71% and 73% of all arthroplasties, respectively. No association between implant designs and achieving an optimal DSA or LSA was observed. None of the implant designs had DSA >65 degrees. The most common cause of failure to reach an optimal LSA in onlay implants was a combination of LSA >95 degrees and DSA <40 degrees. The most common cause of failure in group 3 was DSA <40 degrees. The DSA was negatively correlated with the AI (-0.384; P = 0.006) and CSA (-0.305; P = 0.033). No correlation was observed between the LSA and AI (P = 0.312) or CSA (P = 0.137). Conclusion: The LSA is lower with the Mathys Affinis (TM) implant than with the Biomet Comprehensive (TM) and FH Arrow (TM) implants; however, most LSAs are in the optimal ranges, and no association is observed between different implant designs and optimal DSA and LSA. Implant design, CSA, and AI should be considered during preoperative planning to achieve optimal DSA and LSA.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 33 条
  • [21] Optimal glenoid component inclination in reverse shoulder arthroplasty. How to improve implant stability
    Randelli P.
    Randelli F.
    Arrigoni P.
    Ragone V.
    D'Ambrosi R.
    Masuzzo P.
    Cabitza P.
    Banfi G.
    MUSCULOSKELETAL SURGERY, 2014, 98 (Suppl 1) : S15 - S18
  • [22] A cohort comparison of humeral implant designs in reverse shoulder arthroplasty: does implant design lead to lower rates of complications and revision?
    Gorman, R. Allen, II
    Christmas, Kaitlyn N.
    Simon, Peter
    Mighell, Mark A.
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (04) : 850 - 857
  • [23] The Evolution of Reverse Total Shoulder Arthroplasty-From the First Steps to Novel Implant Designs and Surgical Techniques
    Frank, Julia K.
    Siegert, Paul
    Plachel, Fabian
    Heuberer, Philipp R.
    Huber, Stephanie
    Schanda, Jakob E.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (06)
  • [24] Lateralized glenosphere reverse shoulder arthroplasty: inlay and onlay designs have similar clinical outcomes in patients with glenohumeral osteoarthritis
    Meshram, Prashant
    Joseph, Jacob
    Zhou, Yingjie
    Srikumaran, Uma
    McFarland, Edward G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (04) : 747 - 754
  • [25] Large variability in degree of constraint of reverse total shoulder arthroplasty liners between different implant systems
    Moroder, P.
    Herbst, E.
    Pawelke, J.
    Lappen, S.
    Schulz, E.
    BONE & JOINT OPEN, 2024, 5 (10): : 818 - 824
  • [26] Can Lateralization of Reverse Shoulder Arthroplasty Improve Active External Rotation in Patients with Preoperative Fatty Infiltration of the Infraspinatus and Teres Minor?
    Nabergoj, Marko
    Onishi, Shinzo
    Ladermann, Alexandre
    Kalache, Houssam
    Trebse, Rihard
    Bothorel, Hugo
    Collin, Philippe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [27] Computer modeling and validation testing for glenoid component rotation and optimal glenoid screw angles for reverse shoulder arthroplasty in an Asian population
    Cheng, Shun Sing Martin
    Yung, Colin Shing-Yat
    Wong, Samuel De Hoi
    Yip, Christopher Chun Hei
    Khoo, Issac Jun Ren
    Wong, Tsoi Wan Karen
    Fang, Christian
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (12) : 3151 - 3157
  • [28] High delta angle after reverse total shoulder arthroplasty increases stresses of the acromion: biomechanical study of different implant positions
    Schenk, Pascal
    Sutter, Nikita
    Molina, Erasmo
    Wieser, Karl
    Gerber, Christian
    Bachmann, Elias
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (12) : 2718 - 2724
  • [29] Adjusting Implant Size and Position Can Improve Internal Rotation After Reverse Total Shoulder Arthroplasty in a Three-dimensional Computational Model
    Huish, Eric G., Jr.
    Athwal, George S.
    Neyton, Lionel
    Walch, Gilles
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 198 - 204
  • [30] Analysis of impingement-free range of motion of the glenohumeral joint after reverse total shoulder arthroplasty using three different implant models
    Kim, Sung-Jae
    Jang, Seong-wook
    Jung, Koo-Hyun
    Kim, Yoon Sang
    Lee, Seung-Jin
    Yoo, Yon-sik
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (01) : 87 - 94