Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

被引:17
|
作者
Schultze, V. [1 ]
Scholtes, T. [1 ]
IJsselsteijn, R. [1 ,2 ]
Meyer, H. -G. [1 ]
机构
[1] Leibniz Inst Photon Technol, D-07745 Jena, Germany
[2] Supracon AG, D-07751 Jena, Germany
关键词
NOISE; VAPOR;
D O I
10.1364/JOSAB.32.000730
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F = 4 pumping: F = 3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F = 3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the M-x and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the M-x mode it is more pronounced (about 50 versus 200 fT/root Hz for a 50 mm(3) Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed. (C) 2015 Optical Society of America
引用
收藏
页码:730 / 736
页数:7
相关论文
共 50 条
  • [21] Optically pumped Cs magnetometers enabling a high-sensitivity search for the neutron electric dipole moment
    Abel, C.
    Afach, S.
    Ayres, N. J.
    Ban, G.
    Bison, G.
    Bodek, K.
    Bondar, V
    Chanel, E.
    Chiu, P-J
    Crawford, C. B.
    Chowdhuri, Z.
    Daum, M.
    Emmenegger, S.
    Ferraris-Bouchez, L.
    Fertl, M.
    Franke, B.
    Griffith, W. C.
    Grujic, Z. D.
    Hayen, L.
    Helaine, V
    Hild, N.
    Kasprzak, M.
    Kermaidic, Y.
    Kirch, K.
    Knowles, P.
    Koch, H-C
    Komposch, S.
    Koss, P. A.
    Kozela, A.
    Krempel, J.
    Lauss, B.
    Lefort, T.
    Lemiere, Y.
    Leredde, A.
    Mtchedlishvili, A.
    Mohanmurthy, P.
    Musgrave, M.
    Naviliat-Cuncic, O.
    Pais, D.
    Pazgalev, A.
    Piegsa, F. M.
    Pierre, E.
    Pignol, G.
    Prashanth, P. N.
    Quemener, G.
    Rawlik, M.
    Rebreyend, D.
    Ries, D.
    Roccia, S.
    Rozpedzik, D.
    PHYSICAL REVIEW A, 2020, 101 (05)
  • [22] Optically pumped magnetometers enable a new level of biomagnetic measurements
    Sander, Tilmann
    Jodko-Wladzinska, Anna
    Hartwig, Stefan
    Bruehl, Ruediger
    Middelmann, Thomas
    ADVANCED OPTICAL TECHNOLOGIES, 2020, 9 (05) : 247 - 251
  • [23] Muscle Fatigue Revisited - Insights From Optically Pumped Magnetometers
    Sometti, Davide
    Semeia, Lorenzo
    Baek, Sangyeob
    Chen, Hui
    Righetti, Giulia
    Dax, Juergen
    Kronlage, Cornelius
    Kirchgaessner, Milena
    Romano, Alyssa
    Heilos, Johanna
    Staber, Deborah
    Oppold, Julia
    Middelmann, Thomas
    Braun, Christoph
    Broser, Philip
    Marquetand, Justus
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [24] HYPERFINE RELAXATION OF AN OPTICALLY PUMPED CESIUM VAPOR
    TORNOS, J
    AMARE, JC
    APPLIED SPECTROSCOPY, 1986, 40 (05) : 596 - 599
  • [25] Distributed network of optically pumped magnetometers for space weather monitoring
    Mrozowski, Marcin S.
    Bell, Angus S.
    Griffin, Paul F.
    Hunter, Dominic
    Burt, David
    McGilligan, James P.
    Riis, Erling
    Beggan, Ciaran D.
    Ingleby, Stuart J.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [26] Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers
    Mcwilliam, A. P.
    Dyer, S.
    Hunter, D.
    Mrozowski, M.
    Ingleby, S. J.
    Sharp, O.
    Burt, D. P.
    Griffin, P. F.
    Mcgilligan, J. P.
    Riis, E.
    PHYSICAL REVIEW APPLIED, 2024, 22 (06):
  • [27] Magnetic field imaging with microfabricated optically-pumped magnetometers
    Alem, Orang
    Mhaskar, Rahul
    Jimenez-Martinez, Ricardo
    Sheng, Dong
    LeBlanc, John
    Trahms, Lutz
    Sander, Tilmann
    Kitching, John
    Knappe, Svenja
    OPTICS EXPRESS, 2017, 25 (07): : 7849 - 7858
  • [28] Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils
    Iivanainen, Joonas
    Borna, Amir
    Zetter, Rasmus
    Carter, Tony R.
    Stephen, Julia M.
    McKay, Jim
    Parkkonen, Lauri
    Taulu, Samu
    Schwindt, Peter D. D.
    SENSORS, 2022, 22 (08)
  • [29] A TUNABLE FIBER LASER FOR APPLICATION TO HELIUM OPTICALLY PUMPED MAGNETOMETERS
    LEGARREC, A
    LEGER, JM
    PUREUR, D
    DOUAY, M
    BERNAGE, P
    NIAY, P
    DELEVAQUE, E
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C4): : 695 - 698
  • [30] Optically pumped magnetometers reveal fasciculations non-invasively
    Marquetand, Justus
    Middelmann, Thomas
    Dax, Juergen
    Baek, Sangyeob
    Sometti, Davide
    Grimm, Alexander
    Lerche, Holger
    Martin, Pascal
    Kronlage, Cornelius
    Siegel, Markus
    Braun, Christoph
    Broser, Philip
    CLINICAL NEUROPHYSIOLOGY, 2021, 132 (10) : 2681 - 2684