A comparison of inverse optimization algorithms for HDR/PDR prostate brachytherapy treatment planning

被引:33
|
作者
Dinkla, Anna M. [1 ]
van der Laarse, Rob [1 ]
Kaljouw, Emmie [1 ]
Pieters, Bradley R. [1 ]
Koedooder, Kees [1 ]
van Wieringen, Niek [1 ]
Bel, Arjan [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiat Oncol, NL-1105 AZ Amsterdam, Netherlands
关键词
Prostate neoplasms; Brachytherapy; Inverse planning; IPSA; HIPO; EGO-IIP; DOSE-RATE BRACHYTHERAPY; HDR-BRACHYTHERAPY; ANATOMY; CANCER; BOOST; RECOMMENDATIONS; ESCALATION; CATHETERS; IMPLANT; NUMBER;
D O I
10.1016/j.brachy.2014.09.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Graphical optimization (GrO) is a common method for high-dose-rate/pulsed-dose-rate (PDR) prostate brachytherapy treatment planning. New methods performing inverse optimization of the dose distribution have been developed over the past years. The purpose is to compare GrO and two established inverse methods, inverse planning simulated annealing (IPSA) and hybrid inverse treatment planning and optimization (HIPO), and one new method, enhanced geometric optimization-interactive inverse planning (EGO-IIP), in terms of speed and dose volume histogram (DVH) parameters. METHODS AND MATERIALS: For 26 prostate cancer patients treated with a PDR brachytherapy boost, an experienced treatment planner optimized the dose distributions using four different methods: GrO, IPSA, HIPO, and EGO-IIP. Relevant DVH parameters (prostate-V-100%, D-90%, V-150%; urethra-D-0.1cm3 and D-1.0cm3; rectum-D-0.1cm3 and D-2.0cm3; bladder-D-2.0cm3) were evaluated and their compliance to the constraints. Treatment planning time was also recorded. RESULTS: All inverse methods resulted in shorter planning time (mean, 4-6.7 min), as compared with GrO (mean, 7.6 min). In terms of DVH parameters, none of the inverse methods outperformed the others. However, all inverse methods improved on compliance to the planning constraints as compared with GrO. On average, EGO-IIP and GrO resulted in highest D-90%, and the IPSA plans resulted in lowest bladder D-2.0cm3 and urethra D-1.0cm3. CONCLUSIONS: Inverse planning methods decrease planning time as compared with GrO for PDR/high-dose-rate prostate brachytherapy. DVH parameters are comparable for all methods. (C) 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 50 条
  • [21] Comparison of two inverse planning algorithms for cervical cancer brachytherapy
    Fu, Qi
    Xu, Yingjie
    Zuo, Jing
    An, Jusheng
    Huang, Manni
    Yang, Xi
    Chen, Jiayun
    Yan, Hui
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 157 - 165
  • [22] Healthy tissue constraints for catheter position optimization in HDR prostate brachytherapy planning
    van der Meer, M. C.
    van Dorth, D.
    Bosman, P. A.
    Pieters, B. R.
    Niatsetski, Y.
    Alderliesten, T.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S177 - S179
  • [23] IPSA and HIPO optimisation algorithms for prostate HDR brachytherapy: Comparison with radiobiological indices
    Panettieri, V.
    Smith, L.
    Mason, N. J.
    Beaufort, C.
    Millar, J. L.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S212 - S213
  • [24] Comparison of manuel and inverse optimization methods for HDR tandem-ovoids brachytherapy
    Yumak, B.
    Senkesen, O.
    Tezcanli, E.
    Kabalay, I. Arslan
    Garipagaoglu, M.
    Aslay, I.
    Sengoz, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S319 - S320
  • [25] Harmony Search Optimization for HDR Prostate Brachytherapy
    Panchal, A.
    Tom, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S720 - S721
  • [26] Investigating the role of constrained CVT and CVT in HIPO inverse planning for HDR brachytherapy of prostate cancer
    Sachpazidis, Ilias
    Hense, Juergen
    Mavroidis, Panayiotis
    Gainey, Mark
    Baltas, Dimos
    MEDICAL PHYSICS, 2019, 46 (07) : 2955 - 2968
  • [27] Comparison of CT and ultrasound based treatment planning for treatment of prostate gland using high dose rate (HDR) brachytherapy
    Mirzaei, M
    Lee, WR
    Ekstrand, KE
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S92 - S92
  • [28] Do Prostate HDR Brachytherapy Catheters Shift between Planning and Treatment Delivery?
    Lovett, A.
    Whitaker, M.
    Hruby, G.
    Patanjali, N.
    Dunning, A.
    Ko, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S156 - S157
  • [29] External validation of automated treatment planning for HDR prostate brachytherapy using BRIGHT
    Hansen, Anders T.
    Bouter, Anton
    Bosman, Peter A. N.
    Alderliesten, Tanja
    Buus, Simon
    Johansen, Jacob G.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S341 - S344
  • [30] Evaluation of hybrid inverse planning and optimization (HIPO) algorithm for optimization in real-time, high-dose-rate (HDR) brachytherapy for prostate
    Pokharel, Shyam
    Rana, Suresh
    Blikenstaff, Joseph
    Sadeghi, Amir
    Prestidge, Bradley
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 96 - 107