A fast method for the determination of the efficiency coefficient of bare CR-39 detector

被引:12
|
作者
Dwaikat, Nidal [1 ,2 ]
El-hasan, Mousa [2 ]
Sueyasu, Masto [1 ]
Kada, Wataru [1 ]
Sato, Fuminobu [1 ]
Kato, Yushi [1 ]
Saffarini, G. [2 ]
Iida, Toshiyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Dept Elect Informat Syst & Energy Engn, Osaka, Japan
[2] An Najah Natl Univ, Dept Phys, Nablus, Israel
关键词
Bare CR-39 detector; Efficiency coefficient; (241)Am source; Critical angle; DIFFUSION-CHAMBERS DIMENSIONS; TRACK DETECTOR; THEORETICAL CALCULATION; CALIBRATION FACTOR; RADON MEASUREMENTS;
D O I
10.1016/j.nimb.2010.06.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast and simple method for the determination of the efficiency coefficient (eta) of bare CR-39 detector is presented and discussed. The efficiency coefficient of bare CR-39 detector is then calculated by different ways and the obtained values are found to be comparable to each other. The average value of eta of bare CR-39 is found to be 0.20 +/- 0.01 tracks cm(-2) day(-1) per Bq m(-3). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3351 / 3355
页数:5
相关论文
共 50 条
  • [31] Monitoring fast neutron flux inside spent reactor fuel by CR-39 detector
    Tam, NC
    Lakosi, L
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 601 - 603
  • [32] STRUCTURE EFFECT IN RESPONSE FUNCTION OF CR-39 DETECTOR
    THANG, NX
    DOAN, TT
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 185 - 187
  • [33] Determination of the Bulk Etch Rate of the Nuclear Track Detector CR-39 Using Le-D Method
    Al-Nia'emi, S. H. S.
    Kasim, Y. Y.
    JORDAN JOURNAL OF PHYSICS, 2013, 6 (01): : 17 - 25
  • [34] PROTON RADIOGRAPHIC CHARACTERISTICS OF THIN CR-39 DETECTOR
    WAHEED, A
    MANZOOR, S
    URLEP, I
    ILIC, R
    CHERUBINI, R
    MOSCHINI, G
    SCHIAVON, P
    KHAN, HA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 789 - 792
  • [35] A CURING CYCLE FOR DETECTOR-QUALITY CR-39
    ADAMS, JH
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 348 - 348
  • [36] Study on response of CR-39 detector to light ions
    Yamauchi, T
    Taniguchi, T
    Oda, K
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 261 - 264
  • [37] DIAMETER EVOLUTION OF PROTON TRACKS IN CR-39 DETECTOR
    RAO, YV
    DAVIS, A
    SPENCER, T
    FILZ, RC
    NUCLEAR INSTRUMENTS & METHODS, 1981, 180 (01): : 153 - 156
  • [38] Some more new etchants for CR-39 detector
    Matiullah
    Rehman, S
    Rehman, S
    Mati, N
    Ahmad, S
    RADIATION MEASUREMENTS, 2005, 39 (05) : 551 - 555
  • [39] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, Ashiq Hussain
    Ahmad, Nasir
    Amin, Masood
    Kudo, Katsuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3761 - 3762
  • [40] A parameterization of nuclear track profiles in CR-39 detector
    Azooz, A. A.
    Al-Nia'emi, S. H.
    Al-Jubbori, M. A.
    COMPUTER PHYSICS COMMUNICATIONS, 2012, 183 (11) : 2470 - 2479