Measurement of the volume of a leg ulcer using a laser scanner

被引:11
|
作者
Marjanovic, D
Dugdale, RE
Vowden, P
Vowden, KR
机构
[1] Bradford Royal Infirm, Dept Phys Med, Bradford BD9 6RJ, W Yorkshire, England
[2] Bradford Royal Infirm, Dept Vasc Surg, Bradford BD9 6RJ, W Yorkshire, England
关键词
laser scanning; topography; leg ulcer; volume measurement;
D O I
10.1088/0967-3334/19/4/008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Effective management of leg ulcer healing depends on accurate and reliable measurements of wound size. Current techniques usually rely on estimates of surface area or circumference which do not fully describe the healing process. A novel instrument has been developed that is capable of measuring the variations in the surface contours (topography) of a solid object. Its primary application is to measure the size of a leg ulcer by scanning a laser displacement sensor over the affected area. There is no contact with the wound and scanning takes approximately 2 minutes to perform. Volume is calculated by subtracting the measured topography from one calculated using an algorithm to reconstruct a healthy leg surface. A study was carried out where patients had their ulcers scanned during their visits to the leg ulcer clinic. Data are presented from two venous leg ulcers showing the calculated volume reducing over time.
引用
收藏
页码:535 / 543
页数:9
相关论文
共 50 条
  • [41] Improvements to the accuracy of prototype ship models measurement method using terrestrial laser scanner
    Abbas, Mohd Azwan
    Lichti, Derek D.
    Chong, Albert K.
    Setan, Halim
    Majid, Zulkepli
    Lau, Chong Luh
    Idris, Khairulnizam M.
    Ariff, Mohd Farid Mohd
    MEASUREMENT, 2017, 100 : 301 - 310
  • [42] Laser line scanner aptitude for the measurement of Selective Laser Melting parts
    Cuesta, E.
    Giganto, S.
    Alvarez, B. J.
    Barreiro, J.
    Martinez-Pellitero, S.
    Meana, V
    OPTICS AND LASERS IN ENGINEERING, 2021, 138
  • [43] LEG VOLUME MEASUREMENTS WITH A MODIFIED OPTOELECTRONIC MEASUREMENT SYSTEM
    VERAART, JCJM
    NEUMANN, HAM
    PHLEBOLOGY, 1995, 10 (02) : 62 - 64
  • [44] Using Airborne Laser Scanner Data and CIR Orthophotos to Estimate the Stem Volume of Forest Stands
    Straub, Christoph
    Dees, Matthias
    Weinacker, Holger
    Koch, Barbara
    PHOTOGRAMMETRIE FERNERKUNDUNG GEOINFORMATION, 2009, (03): : 277 - 287
  • [45] MEASUREMENT OF PRESSURE ULCER VOLUME USING DENTAL IMPRESSION MATERIALS - SUGGESTION FROM THE FIELD
    COVINGTON, JS
    GRIFFIN, JW
    MENDIUS, RK
    TOOMS, RE
    CLIFFT, JK
    PHYSICAL THERAPY, 1989, 69 (08): : 690 - 694
  • [46] Reliability of Terrestrial Laser Scanner Measurement in Slope Monitoring
    Abbas, M. A.
    Fuad, N. A.
    Idris, K. M.
    Opaluwa, Y. D.
    Hashim, N. M.
    Majid, Z.
    Sulaiman, S. A.
    4TH INTERNATIONAL CONFERENCE ON RESEARCH METHODOLOGY FOR BUILT ENVIRONMENT AND ENGINEERING 2019, 2019, 385
  • [47] LASER SCANNER FOR EXOELECTRON DISPLAY AND MEASUREMENT OF FATIGUE DAMAGE
    BAXTER, WJ
    JOURNAL OF TESTING AND EVALUATION, 1977, 5 (04) : 243 - 250
  • [48] Measurement of body fat using leg to leg bioimpedance
    Sung, RYT
    Lau, P
    Yu, CW
    Lam, PKW
    Nelson, EAS
    ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 85 (03) : 263 - 267
  • [49] DYNAMIC PHOTOELASTICITY USING A LASER SCANNER
    ASUNDI, A
    SAJAN, MR
    OPTICS AND LASER TECHNOLOGY, 1995, 27 (03): : 153 - 155
  • [50] Development of a three-dimensional vibration measurement system using a single laser scanning vibrometer and laser scanner
    Kim, Dongkyu
    Park, Kyihwan
    2013 13TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2013), 2013, : 1378 - 1380