Optimization of carrier-mediated three-phase hollow fiber microextraction combined with HPLC-UV for determination of propylthiouracil in biological samples

被引:43
|
作者
Ebrahimzadeh, Homeira [1 ]
Asgharinezhad, Ali Akbar [1 ]
Abedi, Hamid [1 ]
Kamarei, Fahimeh [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
关键词
Three-phase hollow fiber microextraction; Propylthiouracil; Carrier-mediated; Biological samples; High performance liquid chromatography; LIQUID-PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; THYREOSTAT RESIDUES; SINGLE-DROP; PRECONCENTRATION; DISPERSION; DRUGS;
D O I
10.1016/j.talanta.2011.05.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carrier-mediated three-phase hollow fiber microextraction combined with high-performance liquid chromatography-ultra violet detection (HPLC-UV) was applied for the extraction and determination of propylthiouracil in biological samples. Propylthiouracil (PTU) was extracted from 7.5 mL of the basic solution (the source phase) with pH 12 into an organic phase (n-octanol containing 6% (w/v) of Aliquat 336 as the carrier) impregnated in the pores of a hollow fiber, and finally was back extracted into 24 mu L. of the acidic solution located inside the lumen of the hollow fiber (the receiving phase). The extraction was performed through the gradient of counter ion from the source to the receiving phase. The effects of different variables on the extraction efficiency were studied simultaneously using an experimental design. A half-fractional factorial design was employed for screening to determine the variables significantly affecting the extraction efficiency. Then, the factors with significant effect were optimized using a central composite design (CCD) and the response surface equations were developed. The optimal experimental conditions obtained from this statistical evaluation included: source phase, pH 12; temperature, 25 degrees C; extraction time, 40 min; counter ion concentration, 2 mol L-1 of NaClO4; organic solvent 6% of Aliquat in octanol and without salt addition in the source phase. Under the optimized conditions, the preconcentration factors were between 125 and 198 and also the limit of detections (LODs) ranged from 0.1 mu g L-1 to 0.4 mu g L-1 in different biological samples. The calibration curve was linear (r(2) = 0.998) in the concentration range of 0.5-1000 mu g L-1. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of FTU in human plasma and urine as well as the bovine milk and meat samples in microgram per liter, and suitable results were obtained (RSDs < 6.3%). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1043 / 1049
页数:7
相关论文
共 50 条
  • [21] Three-phase hollow fiber liquid-phase microextraction combined with HPLC for determination of three trace acidic plant growth regulators in Anoectochilus roxburghii (Wall.) Lindl
    Hong, Ruixia
    Wu, Pingping
    Lin, Jin
    Huang, Liying
    Yang, Lijuan
    Wu, Youjia
    Yao, Hong
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (14) : 2773 - 2783
  • [22] RETRACTED: Preconcentration of Aniline and Catechol with Carrier-mediated Hollow Fiber Liquid-phase Microextraction (Retracted Article)
    Wang, Lei
    Guo, Yugao
    Liang, Shumei
    Guan, Shan
    Wei, Junfu
    2011 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE-ICEES 2011, 2011, 11 : 3478 - 3485
  • [23] Deep eutectic solvent as the acceptor phase in three-phase hollow fiber liquid-phase microextraction for the determination of pyrethroid insecticides from environmental water samples prior to HPLC
    Ezoddin, Maryam
    Naraki, Karim
    Abdi, Khosrou
    Kakavandi, Nader Rahimi
    Ghazi-Khansari, Mahmoud
    Javadi, Mahdiyeh H. S.
    Pirooznia, Nazanin
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (11)
  • [24] HOLLOW FIBER LIQUID PHASE MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR PRECONCENTRATION AND DETERMINATION OF CABERGOLINE IN BIOLOGICAL SAMPLES
    Piroozi, Forozan
    Ghasemi, Ensieh
    Qomi, Mahnaz
    Rezaee, Raheme
    Hashemian, Farshad
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (05) : 760 - 771
  • [25] A deep eutectic solvent based liquid phase microextraction for the determination of caffeine in Turkish coffee samples by HPLC-UV
    Sivrikaya, Sezen
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (03): : 488 - 495
  • [26] Determination of conjugated estrogens in human urine using carrier-mediated hollow-fiber liquid phase microextraction and LC-MS/MS
    Kim, Hyun Young
    Yoon, Su Hyun
    Jeong, Tae-Yong
    Yu, Seungho
    Kim, Sang Don
    DESALINATION AND WATER TREATMENT, 2016, 57 (34) : 16024 - 16033
  • [27] Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples
    M. E. Torres Padrón
    Z. Sosa Ferrera
    J. J. Santana Rodríguez
    Analytical and Bioanalytical Chemistry, 2006, 386 : 332 - 340
  • [28] Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples
    Padron, M. E. Torres
    Ferrera, Z. Sosa
    Rodriguez, J. J. Santana
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (02) : 332 - 340
  • [29] Three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents for determination of tramadol in urine and plasma samples
    Ghambarian, Mahnaz
    Yamini, Yadollah
    Esrafili, Ali
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) : 1041 - 1045
  • [30] Combination of in-situ electro synthesized Zn-Al-LDH@ pencil graphite fiber and three phase hollow fiber LPME for microextraction of some antibiotics in urine samples and quantification via HPLC-UV
    Haidari-Khoshkelat, Leyla
    Raoof, Jahan Bakhsh
    Ghani, Milad
    Ojani, Reza
    ANALYTICA CHIMICA ACTA, 2022, 1235