Immediate Occlusal Loading of Single Lower Molars Using Branemark System® Wide Platform TiUnite™ Implants: A 5-Year Follow-Up Report of a Prospective Clinical Multicenter Study

被引:52
|
作者
Calandriello, Roberto
Tomatis, Massimiliano
机构
[1] Bologna
[2] Bologna
关键词
immediate load; occlusal load; single molar; smokers; TiUnite (TM); un-splinted; wide platform;
D O I
10.1111/j.1708-8208.2009.00214.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Although not essential, molars hold their importance in terms of functional jaw stability, antagonist opposition, and support of facial height. Therefore, implant therapy is an attractive concept in molar areas. However, especially in the posterior mandible, the conventional two-stage surgical approach to implant therapy was reported to cause higher bone loss and/or higher implant failures with machined implants because of the peculiar anatomic and physiologic conditions of this area. As the TiUnite (TM) (Nobel Biocare AB, GOteborg, Sweden) surface results in faster bone healing than with machined-surface implants, it was hypothesized that this surface would also improve the performance of wide implants in posterior mandibles. Based on these assumptions, a protocol for immediately loaded implants for single molar replacement was developed. Purpose: This paper aimed to report on the clinical and radiological performance of Branemark System(R) TiUnite Wide Platform implants supporting single molars in the lower jaw, loaded immediately and followed for up to 5 years, and to assess if the benefit delivered by oxidized surfaces in the short run is also present after 5 years. Materials and Methods: The study includes 33 consecutive patients treated between March 2001 and September 2003 and monitored until September 2008 in two private dental offices. A total of 40 Branemark System TiUnite Wide Platform MK III implants were placed. All implants were provided with provisional crowns in full centric occlusion at the time of surgery. Patients were clinically and radiologically followed up for up to 5 years. Results: Two implant failed so that the cumulative success rate at 5 years was 95.0%. The mean marginal bone remodeling (n = 38) expressed as mesial plus distal value averages was -1.17 mm (SD +/- 0.90) at the 5-year time point. Conclusion: Although limited by the number of patients treated in accordance with the protocol described, 5-year results encourage the use of immediately loaded single lower molars supported by Branemark System Wide Platform TiUnite implants and further document the clinical advantages of titanium oxidized surfaces.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [31] Prospective Clinical Multicenter Study Evaluating the 5-Year Performance of Zirconia Implants in Single-Tooth Gaps
    Gahlert, Michael
    Kniha, Heinz
    Laval, Sabine
    Gellrich, Nils-Claudius
    Bormann, Kai-Hendrik
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 804 - 811
  • [32] High impact of methylation accumulation on cancer risk: 5-year follow-up of a multicenter prospective cohort study
    Maeda, Masahiro
    Nakajima, Takeshi
    Oda, Ichiro
    Shimazu, Taichi
    Yamamichi, Nobutake
    Maekita, Takao
    Asada, Kiyoshi
    Yokoi, Chizu
    Ando, Takayuki
    Yoshida, Takeichi
    Nanjo, Sohachi
    Fujishiro, Mitsuhiro
    Gotoda, Takuji
    Ichinose, Masao
    Ushijima, Toshikazu
    CANCER RESEARCH, 2017, 77
  • [33] Prospective study of monolithic zirconia crowns: clinical behavior and survival rate at a 5-year follow-up
    Fernanda Sola-Ruiz, Ma
    Baixauli-Lopez, Mar
    Roig-Vanaclocha, Ana
    Amengual-Lorenzo, Jose
    Agustin-Panadero, Ruben
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (03) : 284 - 290
  • [34] CLINICAL OUTCOME OF 215 TRANSMUCOSAL IMPLANTS WITH A CONICAL CONNECTION: A RETROSPECTIVE STUDY AFTER 5-YEAR FOLLOW-UP
    Lopez, M. A.
    Bassi, M. Andreasi
    Confalone, L.
    Gaudio, R. M.
    Lombardo, L.
    Lauritano, D.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2016, 30 (02): : 55 - 60
  • [35] Immediate post-extraction implants with or without pure platelet-rich plasma: a 5-year follow-up study
    Taschieri S.
    Lolato A.
    Ofer M.
    Testori T.
    Francetti L.
    Del Fabbro M.
    Oral and Maxillofacial Surgery, 2017, 21 (2) : 147 - 157
  • [36] Flapless Extraction and Immediate Implant Placed Into a Mandibular Molar Site: A Clinical Case Report and 5-Year Follow-Up
    Natto, Zuhair S.
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 159 - 164
  • [37] Prospective Pilot Study of Immediately Provisionalized Restorations of Trabecular Metal-Enhanced Titanium Dental Implants: A 5-Year Follow-Up Report
    van der Schoor, Peter
    Schlee, Markus
    Wen, Hai-Bo
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [38] Implants with an Oxidized Surface Placed Predominately in Soft Bone Quality and Subjected to Immediate Occlusal Loading: Results from an 11-Year Clinical Follow-Up
    Glauser, Roland
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (03) : 429 - 438
  • [39] Implants with an Oxidized Surface Placed Predominately in Soft Bone Quality and Subjected to Immediate Occlusal Loading: Results from a 7-Year Clinical Follow-Up
    Glauser, Roland
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 322 - 331
  • [40] Survival and other clinical outcomes of maintenance hemodialysis patients in Taiwan: A 5-year multicenter follow-up study
    Chen, Huan-Sheng
    Cheng, Chun-Ting
    Hou, Chun-Cheng
    Liou, Hung-Hsiang
    Lim, Paik-Seong