Reliability of MEMS packaging: vacuum maintenance and packaging induced stress

被引:60
|
作者
Choa, SH [1 ]
机构
[1] Samsung Adv Inst Technol, MEMS Lab, Suwon 440600, South Korea
关键词
reliability; wafer level vacuum packaging; leakage; outgassing; packaging induced stress;
D O I
10.1007/s00542-005-0603-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study.. the dominant reliability issues of MEMS packaging that include vacuum maintenance and packaging induced stress, are discussed, and design considerations to improve the reliability are presented. The MEMS vibratory gyroscope sensor is fabricated with anodically bonded wafer level vacuum packaging followed by die-bonding and wire-bonding processes. The epoxy-molding compound (EMC) is applied to encapsulate the gyroscope sensor. Several methods to improve reliability of the vacuum packaging are suggested based on extensive work. The two major failure mechanisms of anodic vacuum packaging, namely leakage and outgassing are investigated. Leakage is effectively reduced by optimization of the bonding process. Outgassing inside the cavity can be minimized by application of Ti coating. Packaging induced stress is mainly caused by thermal expansion mismatch among the materials used to fabricate the package. During anodic bonding, thermo-mechanical stress is generated to the bonded wafer, which increases with temperature. The EMC encapsulation also produces package-induced stress. In order to increase robustness of the structure against deformation, a "crab-leg" type spring is replaced with a semi-folded spring. The results show that the frequency shift is greatly reduced after applying the semifolded spring.
引用
收藏
页码:1187 / 1196
页数:10
相关论文
共 50 条
  • [21] ZrCoCe Getter Films for MEMS Vacuum Packaging
    Yaohua Xu
    Jiandong Cui
    Hang Cui
    Hao Zhou
    Zhimin Yang
    Jun Du
    Journal of Electronic Materials, 2016, 45 : 386 - 390
  • [22] Effects of packaging induced stress on MEMS devices and its improvements
    Choa, Sung-Hoon
    Lee, Moon Chul
    Cho, Yong Chul
    EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2, 2006, 326-328 : 529 - +
  • [23] RELIABILITY, PACKAGING, TESTING, AND CHARACTERIZATION OF MEMS AND MOEMS
    Ramesham, Rajeshuni
    Hartzell, Allyson L.
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2009, 8 (03):
  • [24] Vacuum wafer-level packaging for MEMS applications
    Caplet, S
    Sillon, N
    Delaye, MT
    Berruyer, P
    MICROMACHINING AND MICROFABRICATION PROCESS TECHNOLOGY VIII, 2003, 4979 : 271 - 278
  • [25] A study on wafer level vacuum packaging for MEMS devices
    Lee, B
    Seok, S
    Chun, K
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (05) : 663 - 669
  • [26] Vacuum Packaging of MEMS-based Infrared Detectors
    Roy, Avisek
    Hoang-Vu Nguyen
    Xia, Hexin
    Papatzacos, Phillip
    Ohlckers, Per
    Aasmundtveit, Knut Eilif
    2022 IEEE 9TH ELECTRONICS SYSTEM-INTEGRATION TECHNOLOGY CONFERENCE, ESTC, 2022, : 410 - 415
  • [27] An investigation on NEG thick film for vacuum packaging of MEMS
    Jin, YF
    Wang, ZP
    Zhao, L
    Lim, PC
    Wei, J
    RELIABILITY, TESTING, AND CHARACTERIZATION OF MEMS/MOEMS II, 2003, 4980 : 275 - 280
  • [28] Localized, in-situ vacuum measurements for MEMS packaging
    Moelders, N
    Daly, JT
    Greenwald, AC
    Johnson, EA
    McNeal, MP
    MICRO- AND NANOSYSTEMS, 2004, 782 : 211 - 215
  • [29] VERSATILE VACUUM PACKAGING FOR EXPERIMENTAL STUDY OF RESONANT MEMS
    Schofield, Adam R.
    Trusov, Alexander A.
    Shkel, Andrei M.
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 516 - 519
  • [30] Device-Level Vacuum Packaging for RF MEMS
    Rahman, M. Shahriar
    Chitteboyina, Murali M.
    Butler, Donald P.
    Celik-Butler, Zeynep
    Pacheco, Sergio P.
    McBean, Ronald V.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2010, 19 (04) : 911 - 918