Failure of Primary Distal Biceps Repair After Cortical Button Fixation With Whipstitch Technique: A Root Cause Analysis

被引:1
|
作者
Cheppalli, Naga [1 ]
Metikala, Sreenivasulu [2 ]
Leung, Eric [3 ]
Richter, Dustin L. [1 ]
机构
[1] Univ New Mexico, Orthopaed Surg, Sch Med, Albuquerque, NM USA
[2] Virginia Commonwealth Univ, Orthopaed, Sch Med, Richmond, VA 23284 USA
[3] Univ New Mexico, Orthopaed, Sch Med, Albuquerque, NM USA
关键词
suture stiffness; distal biceps rupture; cheese-wiring; whipstitch; cortical button technique; revision operation; distal biceps tendon repair; TENDON; SUTURE; STITCH;
D O I
10.7759/cureus.21254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rerupture after cortical button fixation and whipstitch suture technique is a rare complication of distal biceps tendon repair. The tendon-bone fixation construct can fail for various reasons, including cortical breach, pull out or disengagement of a cortical button, suture breakage, or knot slippage. Occasionally, a cut-through of the tendon substance by the high-tensile strength suture material, called the 'cheese-wire' effect, can happen, especially with premature loading during the early postoperative period. The clinical presentation is more subtle, and the rerupture may go unnoticed. A high index of suspicion and a low threshold for ordering a magnetic resonance imaging (MRI) scan are necessary for a prompt diagnosis and early treatment. We describe the management of a reruptured distal biceps in an active male that happened in the early postoperative period, along with a critical analysis of the failure pattern and potential preventive measures.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Biomechanical evaluation of distal biceps tendon repair using tension slide technique and knotless fixation technique
    David D. Savin
    Hristo Piponov
    Jonathan N. Watson
    Ari R. Youderian
    Farid Amirouche
    Giovanni F. Solitro
    Mark R. Hutchinson
    Benjamin A. Goldberg
    International Orthopaedics, 2017, 41 : 2565 - 2572
  • [32] Biomechanical evaluation of distal biceps tendon repair using tension slide technique and knotless fixation technique
    Savin, David D.
    Piponov, Hristo
    Watson, Jonathan N.
    Youderian, Ari R.
    Amirouche, Farid
    Solitro, Giovanni F.
    Hutchinson, Mark R.
    Goldberg, Benjamin A.
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (12) : 2565 - 2572
  • [33] Use of a cortical button with the double incision technique for distal biceps tendon avulsion - the importance of the correct drill trajectory
    Benninger, Emanuel
    Meier, Christoph
    SWISS MEDICAL WEEKLY, 2017, 147 : 28S - 28S
  • [34] Distal biceps repair through a single incision with the use of a knotless cortical button device: Mid-term results
    Assiotis, Angelos
    French, Jonathan
    Edwards, Gray
    McCann, Philip A.
    Chalk, Naomi
    Amirfeyz, Rouin
    SHOULDER & ELBOW, 2022, 14 (06) : 677 - 681
  • [35] Posterior Interosseous Nerve Proximity to Cortical Button Implant for Distal Biceps Repair With Single and 2-Incision Approaches
    Strong, Benjamin M.
    Voloshin, Ilya
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (07): : 613 - +
  • [36] Patient-Reported Outcome Measures of a Novel Cortical Button System for Distal Biceps Tendon Repair: A Retrospective Study
    Shean, Kate
    Chowdhury, Alex
    Wilcocks, Katharine
    Blyth, Daniel
    Elmorsy, Ahmed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [37] Biomechanical Comparison of Distal Biceps Tendon Repair Techniques: Extracortical Single-Button Inlay Fixation Versus Intracortical Double-Button Onlay Anatomic Footprint Fixation
    Ernstbrunner, Lukas
    Almond, Mitchell
    Rupasinghe, Harshi S.
    Jo, Olivia I.
    Zbeda, Robert M.
    Ackland, David C.
    Ek, Eugene T.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (07): : 1895 - 1903
  • [38] Extensive Heterotopic Ossification After Suspensory Cortical Fixation of Acute Distal Biceps Tendon Ruptures
    Vidal, Armando F.
    Koonce, Ryan C.
    Wolcott, Michelle
    Gonzales, Joel B.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (07): : 1036 - 1040
  • [39] Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
    Fletcher, Daniel
    Sirch, Francis J.
    Fletcher, Connor
    Beredjiklian, Pedro
    Matzon, Jonas
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [40] Functional outcome after repair of distal biceps tendon ruptures using the endobutton technique
    Peeters, Tom
    Ching-Soon, N. G.
    Jansen, Nick
    Sneyers, Claire
    DecLercq, Geert
    Verstreken, Frederik
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (02) : 283 - 287