Quantifying Particle Coatings Using High-Precision Mass Measurements

被引:8
|
作者
Knudsen, Scott M. [1 ]
von Muhlen, Marcio G. [1 ]
Manalis, Scott R. [1 ,2 ]
机构
[1] MIT, Dept Biol Engn, Cambridge, MA 02139 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
COATED POLYMER MICROSPHERES; PROTEIN; IMMUNOASSAYS; CYTOMETRY; RELEASE; DENSITY; SURFACE;
D O I
10.1021/ac300034r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a general method to quantify coatings on microparticle surfaces based on the additional mass. Particle buoyant mass is determined in a solution with a density that is nearly equivalent to that of the core particle, reducing the magnitude and uncertainty of the measurement. Under these conditions, added material with a different density than that of the core is a larger fraction of the total buoyant mass of the coated particle. This method can resolve a buoyant mass difference between uncoated and coated particles of similar to 1 fg. For the protein layer on the 3 mu m polystyrene spheres measured herein, this is equivalent to 1/10th of a full layer.
引用
收藏
页码:1240 / 1242
页数:3
相关论文
共 50 条
  • [21] Recent high-precision Penning trap mass measurements performed at LEBIT
    Ringle, R.
    LASER 2009: RECENT ACHIEVEMENTS AND FUTURE PROSPECTS, 2010, : 215 - 217
  • [22] Recent high-precision Penning trap mass measurements performed at LEBIT
    Ringle, R.
    HYPERFINE INTERACTIONS, 2010, 196 (1-3): : 215 - 217
  • [23] High-precision regressors for particle physics
    Fady Bishara
    Ayan Paul
    Jennifer Dy
    Scientific Reports, 14
  • [24] High-precision regressors for particle physics
    Bishara, Fady
    Paul, Ayan
    Dy, Jennifer
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [25] High-precision AC measurements using the Monte Carlo method
    Germer, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 457 - 460
  • [26] PHOTOELECTRIC AUTOCOLLIMATOR FOR HIGH-PRECISION MEASUREMENTS
    GOLUBOVSKII, YM
    PIVOVAROVA, LN
    NOVIKOVA, IV
    AFANASEVA, ZK
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1988, 55 (03): : 164 - 166
  • [27] High-precision viscosity measurements on methane
    Vogel, E
    Wilhelm, J
    Küchenmeister, C
    Jaeschke, M
    HIGH TEMPERATURES-HIGH PRESSURES, 2000, 32 (01) : 73 - 81
  • [28] HIGH-PRECISION MEASUREMENTS WITH A BELLOWS VOLUMOMETER
    BACK, PJ
    EASTEAL, AJ
    HURLE, RL
    WOOLF, LA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (03): : 360 - 363
  • [29] Hard magnetic coatings for high-precision microscopy
    JOT, Journal fuer Oberflaechentechnik, 2021, 61 (05):
  • [30] High-precision ND isotopic measurements using Isoprobe-T Thermal Ionization Mass Spectrometer
    Srinivasan, G.
    Das, A.
    METEORITICS & PLANETARY SCIENCE, 2007, 42 : A144 - A144