An alternative approach to adaptive single pole auto-reclosing in high voltage transmission systems based on variable dead time control

被引:99
|
作者
Ahn, SP [1 ]
Kim, CH
Aggarwal, RK
Johns, AT
机构
[1] Sungkyunkwan Univ, Sch Elect & Comp Engn, Suwon 440746, South Korea
[2] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
关键词
adaptive single pole auto-reclosing; dead time control; high voltage transmission lines;
D O I
10.1109/61.956756
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new concept, based on variable dead time control, in adaptive single pole auto-reclosing (SPAR). The proposed scheme can give rise to a high rate of successful reclosing by adapting to variable dead times. The significance of this algorithm is that it uses the waveform patterns of the voltage transients following initial breaker opening. The performance of this proposed method is tested under a variety of fault locations on the Korean 765 kV system, and the outcome of the study clearly indicates that variable dead time auto-reclosing scheme can be used as an attractive and effective means of better management and operation of a high voltage transmission system.
引用
收藏
页码:676 / 686
页数:11
相关论文
共 50 条
  • [41] A New Single Ended Fault Location Method for Transmission Line Based on Positive Sequence Superimposed Network During Auto-Reclosing
    Ji, Liang
    Tao, Xiaojie
    Fu, Yang
    Fu, Yong
    Mi, Yang
    Li, Zhenkun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (03) : 1019 - 1029
  • [42] Three-Phase Adaptive Auto-Reclosing for Single Outgoing Line of Wind Farm Based on Active Detection From STATCOM
    Wang, Ting
    Song, Guobing
    Hussain, Kazmi Sayed Tassawar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (04) : 1918 - 1927
  • [43] A novel concept in adaptive single pole auto-reclosure as applied to HV transmission systems
    Kim, CH
    Ahn, SP
    Aggarwal, RK
    Johns, AT
    APSCOM - 2000: 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN POWER SYSTEM CONTROL, OPERATION & MANAGEMENT, VOLS 1 AND 2, 2000, : 380 - 384
  • [44] Virtual synchronous generator based pole control in high-voltage DC transmission systems
    Hirase, Yuko
    Takeda, Tomoya
    Ohuchi, Kazuki
    ENERGY REPORTS, 2022, 8 : 1073 - 1084
  • [45] A novel approach for optimizing dead time of extra high voltage transmission lines
    Jannati, M.
    Vahidi, B.
    Hosseinian, S. H.
    Baghaee, H. R.
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL I, 2008, : 215 - 220
  • [46] Transmission line single phase auto reclosing scheme based on wavelet transform and adaptive fuzzy neuro inference system
    Khorashadi-Zadeh, H.
    Li, Zuyi
    2007 39TH NORTH AMERICAN POWER SYMPOSIUM, VOLS 1 AND 2, 2007, : 43 - 48
  • [47] Adaptive dead time control for ZVS GaN based CRM Totem Pole PFC
    Liu, Yunfeng
    Huang, Xiaosheng
    Dou, Yi
    Li, Mingxiao
    Ziwei, Ouyang
    Andersen, Michael A. E.
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 438 - 442
  • [48] SELECTION OF VOLTAGE SETTINGS FOR ADAPTIVE SINGLE-PHASE AUTOMATIC RECLOSING APPARATUS FOR EXTRA-HIGH-VOLTAGE TRANSMISSION-LINES
    GNUNI, TC
    POGOSYAN, TA
    ELECTRICAL TECHNOLOGY, 1989, (03): : 11 - 22
  • [49] A High-Speed Adaptive Single-Phase Reclosing Technique Based on Local Voltage Phasors
    Zhalefar, Farzad
    Zadeh, Mohammad R. Dadash
    Sidhu, Tarlochan S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (03) : 1203 - 1211
  • [50] Unscented-Kalman-filter-based single-phase adaptive reclosing of shunt-compensated extra-high-voltage transmission lines
    Saad, Muhammad
    Kim, Chul-Hwan
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (10) : 7759 - 7769