Performance Evaluation of Shunt Active Power Filter (SAPF) connected to Three Phase Four Wire Distribution Networks

被引:0
|
作者
Kaka, Bharadwaj [1 ]
Maji, Abhishek [1 ]
机构
[1] Indian Inst Technol Kanpur, Kanpur, Uttar Pradesh, India
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an Inductor-Capacitor-Inductor (LCL) filter with Sinusoidal Pulse Width Modulation (SPWM) based switching control strategy for four-leg Voltage Source Inverter (4LVSI) in Shunt Active Power Filter (SAPF) to compensate load current harmonics and fundamental frequency voltage unbalances at point of common coupling (PCC). The use of four-leg VSI allows independent control of the load neutral current without having any dc-link capacitor voltage balancing arrangement. Interface LCL filter between 4LVSI and PCC is used to minimize the penetration of the switching frequency component generated by VSI into the grid. Passive damping using resistance in series with the capacitor is provided to avoid resonance oscillations and to improve the stability of SAPF. Dual Second Order Generalized Integrator based Frequency Locked loop (DSOGI-FLL) is used for accurate estimation of synchronous frame angle even under unbalanced and distorted grid operating conditions. Positive Sequence synchronous reference frame ('d-q-0') Proportional-Integral (PI) and Resonant (R) based current controllers with grid voltage feed forward are used for fundamental reactive power and harmonic load current compensation, up-to 25th harmonic order of the fundamental frequency. Concept of harmonic unbalance in load current is introduced and conventional current control scheme is modified in order to compensate unbalance harmonic currents. To increase the speed of compensator reference current generation, positive sequence component of load current is extracted using SOGI (Second Order Generalized Integrator) based QSG (Quadrature Signal Generator) and positive sequence extractor. PI and R based current controllers in stationary reference frame are designed to compensate harmonic zero sequence component of the neutral current. Both balanced and unbalanced voltage sag, swell and flicker at PCC are compensated using two PI based voltage controllers in positive synchronous reference frame (PSRF) and in negative synchronous reference frame (NSRF) respectively. A zero sequence R (resonant) based voltage controller, tuned at fundamental frequency (50 Hz), is designed to compensate zero sequence PCC voltage. Simultaneous compensation of load current harmonics and unbalance PCC voltages are performed by introducing multi-functionality feature into SAPF. Performance of proposed active power filter and the effectiveness of the associated control scheme are demonstrated through MATLAB simulation and validated with experimental results obtained in a 10 kVA laboratory prototype.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Combined Direct Adaptive Controller for a Three-Phase Four-Wire Shunt Active Power Filter
    Sefanello, Marcio
    Pinheiro, Humberto
    Gruendling, Hilton A.
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 872 - 877
  • [22] A Linear Decoupling Control for a PWM Three-Phase Four-Wire Shunt Active Power Filter
    Kanaan, H. Y.
    Georges, S.
    Mendalek, N.
    Hayek, A.
    Al-Haddad, K.
    2008 IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 2008, : 589 - +
  • [23] Computer Studies of the Operation of a Three-Phase Four Wire Shunt Active Power Filter Applied to the Industry
    Nova, Bruno
    Vaz, Diogo
    Passos, Paulo
    Andrade, Nelson
    SUSTAINABLE ENERGY FOR SMART CITIES, SESC 2021, 2022, 425 : 119 - 140
  • [24] Control Strategy of DC Voltage in Three-Phase Four-Wire Shunt Active Power Filter
    Wei, Xueliang
    Liang, Zhishan
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2036 - +
  • [25] Three-phase four-wire shunt active power filter working simultaneously as energy conditioner
    Szromba, Andrzej
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 36 (03) : 702 - 715
  • [26] Research on Three-Phase Four-wire Shunt Active Power Filter for Harmonic and Reactive Compensation
    TianYue-xin
    Cao Hai-yan
    Zhu Yan-ping
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4174 - +
  • [27] High Precision Control Strategy for Three-Phase Four-Wire Shunt Active Power Filter
    Xu, Qunwei
    Zhong, Xiaojian
    Yao, Wenxi
    Chen, Guozhu
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 509 - 514
  • [28] Shunt active filter with three-phase four-wire NPC inverter
    Lin, BR
    Chiang, HK
    Yang, KT
    2004 47TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2004, : 281 - 284
  • [29] A Control Strategy for a Three-Phase Four-Wire Shunt Active Filter
    Ferreira, Filipe
    Monteiro, Luis
    Afonso, Joao L.
    Couto, Carlos
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 360 - 365
  • [30] Three-phase four-wire shunt active filter control strategies
    Aredes, M
    Hafner, J
    Heumann, K
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) : 311 - 318