Non-invasive textile based colorimetric sensor for the simultaneous detection of sweat pH and lactate

被引:177
|
作者
Promphet, Nadtinan [1 ]
Rattanawaleedirojn, Pranee [2 ]
Siralertmukul, Krisana [2 ]
Soatthiyanon, Niphaphun [2 ]
Potiyaraj, Pranut [2 ]
Thanawattano, Chusak [3 ]
Hinestroza, Juan P. [4 ]
Rodthongkum, Nadnudda [2 ]
机构
[1] Chulalongkorn Univ, Grad Sch, Nanosci & Technol Interdisciplinary Program, Phayathai Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Met & Mat Sci Res Inst, Soi Chula 12,Phayathai Rd, Bangkok 10330, Thailand
[3] Natl Elect & Comp Technol Ctr NECTEC, Pathum Thani 12120, Thailand
[4] Cornell Univ, Coll Human Ecol, Dept Fiber Sci, Ithaca, NY 14850 USA
关键词
Non-invasive; Textile; Cotton; Sweat; PH; Lactate; Calorimetric sensor; ELECTROCHEMICAL DETECTION; BIOSENSOR; DEVICE;
D O I
10.1016/j.talanta.2018.09.086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-invasive textile-based colorimetric sensor for the simultaneous detection of sweat pH and lactate was created by depositing of three different layers onto a cotton fabric: 1.) chitosan, 2.) sodium carboxymethyl cellulose, and 3.) indicator dye or lactate assay. This sensor was characterized using field emission scanning electron microscopy and fourier transform infrared spectroscopy. Then, this sensor was used to measure pH and lactate concentration using the same sweat sample. The sensing element for sweat pH was composed of a mixture of methyl orange and bromocresol green while a lactate enzymatic assay was chosen for the lactate sensor. The pH indicator gradually shifted from red to blue as the pH increased, whereas the purple color intensity increased with the concentration of lactate in the sweat. By comparing these colors with a standard calibration, this platform can be used to estimate the sweat pH (1 - 14) and the lactate level (0-25 mM). Fading of the colors of this sensor was prevented by using cetyltrimethylammonium bromide (CTAB). The flexibility of this textile based sensor allows it to be incorporated into sport apparels and accessories hence potentially enabling real-time and continuous monitoring of sweat pH and lactate. This non-invasive sensing platform might open a new avenue for personal health monitoring and medical diagnosis as well as for determining of the physiological conditions of endurance athletes.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 50 条
  • [41] Non-invasive biomedical sensor
    Ling, D
    Bullock, AM
    OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 32 - 41
  • [42] A dual-functional polyaniline film-based flexible electrochemical sensor for the detection of pH and lactate in sweat of the human body
    Zhu, Chonghui
    Xue, Hua
    Zhao, Hongran
    Fei, Teng
    Liu, Sen
    Chen, Qidai
    Gao, Bingrong
    Zhang, Tong
    TALANTA, 2022, 242
  • [43] Liquid-crystal-based fiber laser sensor for non-invasive gas detection
    Zhou, Dong
    Wang, Qingxiu
    Lan, Zeqing
    Chen, Yuzhou
    Peng, Zenghui
    Zhang, Lingli
    Liu, Yongjun
    OPTICS LETTERS, 2023, 48 (17) : 4508 - 4511
  • [44] Soft sensor for non-invasive detection of process events based on Eigenresponse Fuzzy Clustering
    Strzinar, Ziga
    Pregelj, Bostjan
    Skrjanc, Igor
    APPLIED SOFT COMPUTING, 2023, 132
  • [45] Non-Invasive Microwave CSRR-Based Sensor for Diabetic Foot Ulcers Detection
    Bait-Suwailam, Mohammed M.
    Bahadur, Issam
    2021 18TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2021, : 1237 - 1240
  • [46] In-silico investigation towards the non-invasive optical detection of blood lactate
    Chatterjee, Subhasri
    Budidha, Karthik
    Qassem, Meha
    Kyriacou, Panicos A.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] In-silico investigation towards the non-invasive optical detection of blood lactate
    Subhasri Chatterjee
    Karthik Budidha
    Meha Qassem
    Panicos A. Kyriacou
    Scientific Reports, 11
  • [48] Non-invasive hormone monitoring with a wearable sweat biosensor
    Lee, Yerim
    Gao, Wei
    NATURE REVIEWS BIOENGINEERING, 2025, 3 (03): : 190 - 191
  • [49] Non-invasive monitoring of lactate by reverse iontophoresis
    Nixon, S.
    Delgado-Charro, M. B.
    Guy, R. H.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2004, 56 : S57 - S58
  • [50] Printed Organic Transistor-based Biosensors for Non-invasive Sweat Analysis
    Nagamine, Kuniaki
    Nomura, Ayako
    Ichimura, Yusuke
    Izawa, Ryota
    Sasaki, Shiori
    Furusawa, Hiroyuki
    Matsui, Hiroyuki
    Tokito, Shizuo
    ANALYTICAL SCIENCES, 2020, 36 (03) : 291 - 302