Physical characterization and comparison of two commercially available micro-MLCs

被引:6
|
作者
Podder, Tarun K. [1 ]
Bednarz, Greg [2 ]
Yu, Yan [1 ]
Galvin, James M. [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiat Oncol, Kimmel Canc Ctr NCI Designated, Jefferson Med Coll, Philadelphia, PA 19107 USA
[2] Univ Pittsburgh, Med Ctr, Dept Radiat Oncol, UPMC Canc Ctr, Pittsburgh, PA 15232 USA
关键词
Micromulti-leaf collimator; Penumbra; Interleaf leakage; Tongue-and-groove effect; Focal spot; IMRT; MULTILEAF COLLIMATOR SYSTEM;
D O I
10.1016/j.ejmp.2010.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the physical characteristics (penumbra width variation with the source size and shape, interleaf leakage, transmission through the leaves, and the tongue-and-groove effect) of two linear accelerators (BrainLAB's Novalis and Elekta's Synergy-S Beam Modulator) have been investigated. For similar square fields (about 4.5 cm x 4.5 cm) with source-to-surface/skin-distance (SSD) ranging from 90 cm to 115 cm and measurements taken at the depth of D(max) = 1.5 cm for 6 MV photon beam. The Novalis MLC has penumbra width of 2.4 +/- 0.11 mm-2.8 +/- 0.11 mm at the leaf-end and 2.2 +/- 0.1 mm-2.7 +/- 0.1 mm on the leaf-side; and those for the Synergy-S MLC are 4.4 +/- 0.17 mm-5.2 +/- 0.2 mm and 3.0 +/- 0.12 mm-3.5 +/- 0.12 mm. Upon rotating the Synergy-S collimator by 90 degrees (i.e., shifting the leaf movement to the gun target direction), significant reduction of the leaf-end penumbra width (17%) and increase of leaf-side penumbra width (28%) suggest an elliptical shape of the radiation source spot. Similar rotation of the collimator yielded reduction of the penumbras on both leaf-end (34%) and leaf-side (28%) for Novalis, indicating that the Novalis has a more symmetric source size. For all the field sizes and settings, BrainLAB's Novalis mu MLC produce a smaller penumbra for simple square fields compared to the Elekta's Synergy-S. However, this difference became less pronounced for leaf-side penumbra and also for circular fields. The tongue-and-groove effect of the Novalis (23 +/- 0.9%) is slightly smaller than that of the Synergy-S (25 +/- 1%); while the interleaf leakage and leakage directly through leaves for Synergy-S (1.6 +/- 0.07% a 0.9 +/- 0.04%) are lower than that of Novalis (2 +/- 0.08% & 1.3 +/- 0.05%). (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [41] Polarity effect of commercially available micro ionization chambers
    Lazarescu, G
    Das, I
    Avery, S
    Cheng, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1832 - 1832
  • [42] A black and white comparison of commercially available dermatoscopes
    Marson, Justin W.
    Tongdee, Emily
    Chen, Rebecca M.
    Mojeski, Jacob
    Mondok, Christopher
    Schneider, Jane A.
    Siegel, Daniel M.
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 2023, 62 (10) : E551 - E553
  • [43] Comparison of 2 commercially available chlorhexidine mouthrinses
    Keijser, JAM
    Verkade, H
    Timmerman, MF
    Van der Weijden, FA
    JOURNAL OF PERIODONTOLOGY, 2003, 74 (02) : 214 - 218
  • [44] COMPARISON OF 4 COMMERCIALLY AVAILABLE CAMP KITS
    VOSSENBERG, J
    MULDER, G
    THIJSSEN, J
    BRUYNZEEL, P
    HAMELINK, M
    KREUKNIET, J
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1979, 17 (09): : 581 - 585
  • [45] A comparison of commercially available software for the prediction of pKa
    Dearden, J. C.
    Cronin, M. T. D.
    Lappin, D. C.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 : A7 - A7
  • [46] CLINICAL COMPARISON OF COMMERCIALLY AVAILABLE BIOBRANE PREPARATIONS
    YANG, JY
    TSAI, YC
    NOORDHOFF, MS
    BURNS, 1989, 15 (03) : 197 - 203
  • [47] A COMPARISON OF COMMERCIALLY AVAILABLE ADJUVANTS FOR USE IN RESEARCH
    BENNETT, B
    CHECK, IJ
    OLSEN, MR
    HUNTER, RL
    JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 153 (1-2) : 31 - 40
  • [48] COMPARISON OF EFFICIENCY OF COMMERCIALLY AVAILABLE PHOTOTHERAPY UNITS
    LEVENE, MI
    HILLS, WG
    SANDHU, B
    ARCHIVES OF DISEASE IN CHILDHOOD, 1980, 55 (05) : 399 - 401
  • [49] A COMPARISON OF COMMERCIALLY AVAILABLE MOLD SURVEY SERVICES
    ROGERS, SA
    ANNALS OF ALLERGY, 1983, 50 (01): : 37 - 40
  • [50] Characterization of commercially available honey in Puerto Rico
    Lopez, Jonathan Becerra
    Flores-Morales, Reynell
    Munoz, Astrid
    Perez-Rodriguez, Carolina
    Figueroa-Cruz, Marc
    Maiz, Rene
    Blanco, Krystal
    Morales-Velez, Jeancarlo
    Camacho, Christian
    Gomez-Torres, Jeilenne
    Negron, Angel Vega
    Gonzalez, Angela
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253