Research on DC Microgrid Protection Based on Improved Dual-Slope Current Differential Protection

被引:0
|
作者
Wang, Mingyang [1 ]
Chen, Qing [1 ]
Chen, Liuyang [1 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan, Peoples R China
关键词
DC microgrid; differential protection; dual-slope; inverse time characteristic; FAULT PROTECTION;
D O I
10.1109/SCEMS48876.2020.9352314
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a fault detection method based on an improved dual-slope current differential protection. Traditional current differential protection needs to consider both the action sensitivity in the case of internal faults and the protection reliability in case of external faults. The braking coefficient cannot be set too low, so the sensitivity to internal high-impedance faults is low. For this reason, this paper improves the traditional current differential protection. On the basis of the dual-slope current differential protection method, it adds a judgment delay time with inverse time characteristics. Without changing the original performance of the differential protection, it increases its sensitivity to internal high-impedance faults improves the power supply capacity of the system.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 50 条
  • [21] A New Transmission Line Differential Protection based on Fault current DC Transients
    Latha, Adharapurapu Hema
    Bhimasingu, Ravikumar
    Katta, Sobhan Babu
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [22] A Current-Mode Dual-Slope CMOS Temperature Sensor
    Hung, Chung-Chih
    Chu, Hsing-Chien
    IEEE SENSORS JOURNAL, 2016, 16 (07) : 1898 - 1907
  • [23] Pilot Protection Scheme for DC Lines Based on Ratio of Differential Current to Distributed Capacitive Current
    Chu B.
    Li H.
    Peng G.
    Liang Y.
    Wang G.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (09): : 162 - 170
  • [24] Pilot protection method for flexible DC distribution lines based on fitted current slope characteristics
    Zhang X.
    Fan Y.
    Ma J.
    Liu Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (18): : 128 - 136
  • [25] Research on Microgrid Protection Based on Transient Polarity Comparison
    Ma, Xiaowei
    Li, Bin
    Wang, Qingping
    Bo, Zhiqian
    Zhang, Ming
    Ma, Xiaolin
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [26] Unit Protection of Tapped Line DC Microgrid
    Rao, Gade Kesava
    Jena, Premalata
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (04) : 4680 - 4689
  • [27] Fault Analysis and Protection of Ring DC Microgrid
    Zhang W.
    Zhang H.
    Zhi N.
    Wang H.
    Shi H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (24): : 105 - 110
  • [28] Review on Fault Protection Technologies of DC Microgrid
    Nian H.
    Kong L.
    Nian, Heng (nianheng@zju.edu.cn), 1600, Science Press (46): : 2241 - 2254
  • [29] Protection of DC microgrid using.CB
    Abed, Marwan R.
    Ahmed, Oday A.
    Bilal, Ghassan A.
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (11): : 146 - 150
  • [30] Autonomous Protection of Low Voltage DC Microgrid
    Patil, Ganesh
    Satarkar, M. F. A. R.
    2014 INTERNATIONAL CONFERENCE ON POWER, AUTOMATION AND COMMUNICATION (INPAC), 2014, : 23 - 26