Improved non-destructive 2D and 3D X-ray imaging of leaf venation

被引:22
|
作者
Schneider, Julio V. [1 ,2 ,3 ]
Rabenstein, Renate [2 ,4 ]
Wesenberg, Jens [5 ]
Wesche, Karsten [5 ,6 ,7 ]
Zizka, Georg [1 ,2 ,3 ]
Habersetzer, Joerg [2 ,4 ]
机构
[1] Senckenberg Res Inst, Dept Bot & Mol Evolut, Senckenberganlage 25, D-60325 Frankfurt, Germany
[2] Nat Hist Museum Frankfurt, Senckenberganlage 25, D-60325 Frankfurt, Germany
[3] Goethe Univ, Inst Ecol Evolut & Divers, Max von Laue Str 13, D-60439 Frankfurt, Germany
[4] Senckenberg Res Inst, Dept Messel Res & Mammal, Senckenberganlage 25, D-60325 Frankfurt, Germany
[5] Senckenberg Museum Nat Hist Gorlitz, Dept Bot, Museum 1, D-02826 Gorlitz, Germany
[6] German Ctr Integrat Biodivers Res iDiv, Deutsch Pl 5e, D-04103 Leipzig, Germany
[7] Tech Univ Dresden, Int Inst Zittau, Markt 23, D-02763 Zittau, Germany
关键词
Contact microradiography; Image processing; Leaf clearing; Micro CT; Vein networks; Vein density; EVOLUTION; VISUALIZATION; SIZE;
D O I
10.1186/s13007-018-0274-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Leaf venation traits are important for many research fields such as systematics and evolutionary biology, plant physiology, climate change, and paleoecology. In spite of an increasing demand for vein trait data, studies are often still data-limited because the development of methods that allow rapid generation of large sets of vein data has lagged behind. Recently, non-destructive X-ray technology has proven useful as an alternative to traditional slow and destructive chemical-based methods. Non-destructive techniques more readily allow the use of herbarium specimens, which provide an invaluable but underexploited resource of vein data and related environmental information. The utility of 2D X-ray technology and microfocus X-ray computed tomography, however, has been compromised by insufficient image resolution. Here, we advanced X-ray technology by increasing image resolution and throughput without the application of contrast agents. Results: For 2D contact microradiography, we developed a method which allowed us to achieve image resolutions of up to 7 mu m, i.e. a 3.6-fold increase compared to the industrial standard (25 mu m resolution). Vein tracing was further optimized with our image processing standards that were specifically adjusted for different types of leaf structure and the needs of higher imaging throughput. Based on a test dataset, in 91% of the samples the 7 mu m approach led to a significant improvement in estimations of minor vein density compared to the industrial standard. Using microfocus X-ray computed tomography, very high-resolution images were obtained from a virtual 3D-2D transformation process, which was superior to that of 3D images. Conclusions: Our 2D X-ray method with a significantly improved resolution advances rapid non-destructive bulk scanning at a quality that in many cases is sufficient to determine key venation traits. Together with our high-resolution microfocus X-ray computed tomography method, both non-destructive approaches will help in vein trait data mining from museum collections, which provide an underexploited resource of historical and recent data on environmental and evolutionary change. In spite of the significant increase in effective image resolution, a combination of high-throughput and full visibility of the vein network ( including the smallest veins and their connectivity) remains challenging, however.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Detecting Bombs in X-Ray Images of Hold Baggage: 2D Versus 3D Imaging
    Hattenschwiler, Nicole
    Mendes, Marcia
    Schwaninger, Adrian
    HUMAN FACTORS, 2019, 61 (02) : 305 - 321
  • [42] Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette
    Siewerdsen, Jeffrey H. H.
    MEDICAL PHYSICS, 2023, 50 (S1) : 109 - 116
  • [43] Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast
    Baneva, Yanka
    Bliznakova, Kristina
    Cockmartin, Lesley
    Marinov, Stoyko
    Buliev, Ivan
    Mettivier, Giovanni
    Bosmans, Hilde
    Russo, Paolo
    Marshall, Nicholas
    Bliznakov, Zhivko
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 78 - 86
  • [44] A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system
    Ros Wade
    Huiqin Yang
    Claire McKenna
    Rita Faria
    Nigel Gummerson
    Nerys Woolacott
    European Spine Journal, 2013, 22 : 296 - 304
  • [45] X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants
    Karch, J.
    Dudak, J.
    Zemlicka, J.
    Vavrik, D.
    Kumpova, I.
    Kvacek, J.
    Hermanova, Z.
    Soltes, J.
    Viererbl, L.
    Morgano, M.
    Kaestner, A.
    Trtik, P.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [46] Advanced Non-Destructive Ocular Visualization Methods by Improved X-Ray Imaging Techniques
    Enders, Christian
    Braig, Eva-Maria
    Scherer, Kai
    Werner, Jens U.
    Lang, Gerhard K.
    Lang, Gabriele E.
    Pfeiffer, Franz
    Noel, Peter
    Rummeny, Ernst
    Herzen, Julia
    PLOS ONE, 2017, 12 (01):
  • [47] New robotic tools for multimodal non-destructive analysis and characterization of 2D and 3D objects
    Kotrly, Marek
    Uher, Josef
    Jakubek, Jan
    Skala, Roman
    Bohacova, Jana
    Turkova, Ivana
    Starkbaumova, Kamila
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2025, 58 : 168 - 179
  • [48] Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced composites
    Hanhan, Imad
    Agyei, Ronald
    Xiao, Xianghui
    Sangid, Michael D.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2019, 184
  • [49] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [50] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436