Stability of the LEBRA infrared FEL

被引:0
|
作者
Yokoyama, K
Sato, I
Hayakawa, K
Tanaka, T
Hayakawa, Y
Kanno, K
Sakai, T
Ishiwata, K
Hashimoto, E
机构
[1] Nihon Univ, Lab Electron Beam Res & Applicat, Funabashi, Chiba 2748501, Japan
[2] Nihon Univ, Grad Sch Sci & Technol, Funabashi, Chiba 2748501, Japan
关键词
FEL; electron linac; near-IR; RF;
D O I
10.1016/S0168-9002(03)00920-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The free electron laser (FEL) gain and the power have still been unstable, although the lasing of 1.5 mum FEL was achieved at the Laboratory for Electron Beam Research and Application (LEBRA). It has been observed that the FEL gain changes during the pulse duration. In order to investigate the cause of the fluctuation of the FEL gain, the beam energy spectra in the pulse duration and the IR light signals were measured with different input RF power and RF phase of the injector. It is found that the fluctuation of the beam energy during the pulse duration occurs in spite of the RF phase flatness (<0.5degrees/20 mus). (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [1] Observation of SASE in LEBRA FEL system
    Tanaka, T
    Hayakawa, K
    Sato, I
    Hayakawa, Y
    Yokoyama, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 528 (1-2): : 486 - 490
  • [2] Simultaneous measurement of the fundamental and third harmonic FEL at LEBRA
    Hayakawa, Y
    Sato, I
    Hayakawa, K
    Tanaka, T
    Yokoyama, K
    Sakai, T
    Kanno, K
    Ishiwata, K
    Hashimoto, E
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2002, 41 (01): : 54 - 57
  • [3] Characteristics of the fundamental FEL and the higher harmonic generation at LEBRA
    Hayakawa, Y
    Sato, I
    Hayakawa, K
    Tanaka, T
    Yokoyama, K
    Kanno, K
    Sakai, T
    Ishiwata, K
    Nakao, K
    Hashimoto, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 507 (1-2): : 404 - 408
  • [4] First lasing of LEBRA FEL at Nihon University at a wavelength of 1.5 μm
    Hayakawa, Y
    Sato, I
    Hayakawa, K
    Tanaka, T
    Nakazawa, H
    Yokoyama, K
    Kanno, K
    Sakai, T
    Ishiwata, K
    Enomoto, A
    Fukuda, S
    Ohsawa, S
    Tsuchiya, K
    Kato, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2): : 29 - 33
  • [5] Viability of infrared FEL facilities
    Schwettman, HA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 528 (1-2): : 1 - 7
  • [6] REGIONS OF STABILITY OF FEL OSCILLATORS
    LEVUSH, B
    ANTONSEN, TM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (1-2): : 375 - 379
  • [7] Regions of stability of FEL oscillators
    Levush, B.
    Antonsen Jr., T.M.
    Nuclear instruments and methods in physics research, 1988, 272 (1-2): : 375 - 379
  • [8] Requirements of microwave stability in FEL
    Li, Ming
    Zhang, Guo-Qing
    Zhuang, Jie-Jia
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2002, 14 (03): : 418 - 420
  • [9] Optical performance of the CLIO infrared FEL
    Prazeres, R.
    Berset, J.M.
    Glotin, F.
    Jaroszynski, D.
    Ortega, J.M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A331 (1-3) : 15 - 19
  • [10] New results of the 'CLIO' infrared FEL
    Prazeres, R
    Glotin, F
    Ortega, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 528 (1-2): : 83 - 87