Requirements of microwave stability in FEL

被引:0
|
作者
Li, Ming [1 ]
Zhang, Guo-Qing [1 ]
Zhuang, Jie-Jia [1 ]
机构
[1] Inst. of High Energy Phys., Chinese Acad. of Sci., P. O. Box 2732, Beijing 100080, China
关键词
Electron beams - Microwaves - Phase locked loops - Stability;
D O I
暂无
中图分类号
学科分类号
摘要
The stability of the free electron laser output is mainly determined by the stability of the electron beam, and the stability of the electron beam based on RF linac is mainly determined by the stability of the microwave source. To realize the saturation output of FEL and to get better FEL spectrum purity, the amplitude and phase stability of RF power must be very high according to FEL theory. The FEL stability and its requirements on microwave stability were discussed, and the required parameters of microwave stability for CAEP FIR-FEL and BFEL were obtained.
引用
收藏
页码:418 / 420
相关论文
共 50 条
  • [1] Microwave FEL experiments at CESTA
    Launspach, J.
    Anthouard, Ph.
    Bardy, J.
    Bonnafond, C.
    Bottollier-Curtet, H.
    Delsart, Ph.
    Devin, A.
    Eyharts, Ph.
    Eyl, P.
    Gardelle, J.
    Gardent, D.
    Germain, G.
    Grua, P.
    Labrouche, J.
    Le Taillandier, P.
    et al
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A331 (1-3) : 149 - 151
  • [2] MICROWAVE FEL EXPERIMENTS AT CESTA
    LAUNSPACH, J
    ANTHOUARD, P
    BARDY, J
    BONNAFOND, C
    BOTTOLLIERCURTET, H
    DELSART, P
    DEVIN, A
    EYHARTS, P
    EYL, P
    GARDELLE, J
    GARDENT, D
    GERMAIN, G
    GRUA, P
    LABROUCHE, J
    LETAILLANDIER, P
    DEMASCUREAU, J
    MERLE, E
    ROQUES, A
    THEVENOT, M
    VILLATE, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 331 (1-3): : 149 - 151
  • [3] Microwave FEL amplifier experiment
    Su, Yi
    Huang, Sunren
    Chen, Yutao
    Shen, Yuanfa
    Fu, Shuzhen
    Liu, Xishan
    Li, Zhenrong
    Hu, Kesong
    Nuclear instruments and methods in physics research, 1988, 272 (1-2): : 147 - 149
  • [4] INDUSTRIAL MICROWAVE FEL DEVICES
    DEARDEN, G
    QUIRK, EG
    LUCAS, J
    STUART, RA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 318 (1-3): : 230 - 234
  • [5] A MICROWAVE FEL AMPLIFIER EXPERIMENT
    SU, Y
    HUANG, SR
    CHEN, YT
    SHEN, YF
    FU, SZ
    LIU, XS
    LI, ZR
    HU, KS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (1-2): : 147 - 149
  • [6] Status of the microwave inverse FEL experiment
    Yoder, RB
    Zhang, TB
    Marshall, TC
    Wang, M
    Hirshfield, JL
    FREE ELECTRON LASERS 1998, 1999, : II27 - II28
  • [7] Status of the microwave inverse FEL experiment
    Yoder, RB
    Marshall, TC
    Wang, M
    Hirshfield, JL
    ADVANCED ACCELERATOR CONCEPTS, EIGHTH WORKSHOP, 1999, 472 : 635 - 643
  • [8] Stability of the LEBRA infrared FEL
    Yokoyama, K
    Sato, I
    Hayakawa, K
    Tanaka, T
    Hayakawa, Y
    Kanno, K
    Sakai, T
    Ishiwata, K
    Hashimoto, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 507 (1-2): : 357 - 361
  • [9] REGIONS OF STABILITY OF FEL OSCILLATORS
    LEVUSH, B
    ANTONSEN, TM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (1-2): : 375 - 379
  • [10] Regions of stability of FEL oscillators
    Levush, B.
    Antonsen Jr., T.M.
    Nuclear instruments and methods in physics research, 1988, 272 (1-2): : 375 - 379