A knowledge-based computer-aided system for closed diaphyseal fracture reduction

被引:23
|
作者
Koo, Terry K. K.
Mak, Arthur F. T.
机构
[1] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
[2] New York Chiropract Coll, Dept Basic Sci, Seneca Falls, NY 13148 USA
[3] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
关键词
closed fracture reduction; external fixation; computer-aided surgery; diaphyseal fracture;
D O I
10.1016/j.clinbiomech.2007.05.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background We recently developed an algorithm to perform closed fracture reduction using unilateral external fixator. Although its validity has been verified experimentally, the whole reduction process was not evaluated owing to the lack of a device that could facilitate its implementation in clinical practice. The objective of this study is to develop a prototype of such a system, and quantify its reduction accuracy. Methods. The system consists of a custom-made unilateral external device and a self-contained software package. The device features 7 one degree of freedom joints, each allows for continuous adjustments and is equipped with measurement components to facilitate accurate positioning. A CT-based method was developed, which facilitates virtual reduction and calculates the adjustment requirements that reduce a fracture deformity. The device was adjusted off-the-site and reattached back in place to guide the reduction of the fracture fragments. Reduction accuracy was evaluated using eight phantoms of different types, sides and fracture patterns by calculating the rotation about a screw axis and the displacement between the origins of the distal and proximal local coordinate systems after the reduction. Findings. The mean (SD) of the translational and rotational reduction errors were 1.73 (0.97) mm and 2.57 degrees (1.36 degrees), respectively, which demonstrated the accuracy and reliability of the system. Interpretation. The system allows surgeons to perform fracture reduction in an objective, efficient, and accurate manner yet minimize the radiation exposure and lessens the extent of tissue disruption around the fracture site during the reduction process. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:884 / 893
页数:10
相关论文
共 50 条
  • [21] A knowledge-based environment for modelling and computer-aided process planning of rapid manufacturing processes
    Deglin, A
    Bernard, A
    INTEGRATED DESIGN AND MANUFACTURING IN MECHANICAL ENGINEERING, 2002, : 85 - 92
  • [22] Physics- and Engineering Knowledge-Based Repair of Computer-Aided Design Parametric Geometries
    Li, Dong
    Sobester, Andras
    Keane, Andy J.
    AIAA JOURNAL, 2012, 50 (06) : 1409 - 1414
  • [23] Object-oriented knowledge-based computer-aided process planning system for bare circuit boards manufacturing
    Law, HW
    Tam, HY
    Chan, AHS
    Hui, IK
    COMPUTERS IN INDUSTRY, 2001, 45 (02) : 137 - 153
  • [24] KNOWLEDGE-BASED APPROACH OF BUILDING PLAN CHECKER SYSTEM USING COMPUTER-AIDED DESIGN (CAD) BUILDING PLAN
    Sanusi, Nurazlina Md
    Mustafa, Nuridawati
    Kasmuri, Emaliana
    Azmi, Mohd Sanusi
    INTERNATIONAL CONFERENCE ON FUTURE COMPUTER AND COMMUNICATIONS, PROCEEDINGS, 2009, : 8 - 10
  • [25] A knowledge-based framework for integration of computer aided styling and computer aided engineering
    Stadler S.
    Hirz M.
    Stadler, Severin (severin.stadler@magna.com), 2016, Bellwether Publishing, Ltd. (13): : 558 - 569
  • [26] A visual servo-based teleoperation robot system for closed diaphyseal fracture reduction
    Li, Changsheng
    Wang, Tianmiao
    Hu, Lei
    Zhang, Lihai
    Du, Hailong
    Zhao, Lu
    Wang, Lifeng
    Tang, Peifu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (09) : 629 - 637
  • [27] Development of a computer-aided process planning system based on a knowledge base
    Sasaki, Y
    Sonda, M
    Ito, K
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY, 2003, 7 (04) : 175 - 179
  • [28] Development of a computer-aided process planning system based on a knowledge base
    Yuichi Sasaki
    Masahiro Sonda
    Ken Ito
    Journal of Marine Science and Technology, 2003, 7 : 175 - 179
  • [29] Computer-aided innovative system of mechanical products based on patent knowledge
    Qiu, Qing-Ying
    Xue, Chi
    Ji, Yu
    Feng, Pei-En
    Jisuanji Jicheng Zhizao Xitong/Computer Integrated Manufacturing Systems, CIMS, 2013, 19 (02): : 354 - 361
  • [30] Devices and methods for closed reduction of diaphyseal fracture
    Foot Levelers Biomechanics Research Laboratory, Department of Research, New York Chiropractic College, 2360 State Route 89, Seneca Falls, NY 13148-3204, United States
    Recent Pat. Biomed. Eng., 2009, 2 (85-96):