Factors influencing daily quality assurance measurements of magnetic resonance imaging scanners

被引:3
|
作者
Owusu, Nana [1 ,2 ]
Magnotta, Vincent A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52240 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52240 USA
[3] Univ Iowa, Dept Psychiat, Iowa City, IA 52240 USA
[4] 169 Newton Rd, Iowa City, IA 52242 USA
关键词
Magnetic resonance imaging; Signal-to-noise ratio; Quality assurance; MRI;
D O I
10.1007/s12194-021-00638-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging is commonly used in hospitals and clinics to aid medical diagnoses. Scanner performance should be assessed regularly, including daily, weekly, and yearly evaluations to ensure high-quality and artifact-free images. Of these assessments, the daily quality assurance monitors the image quality of the scanner using a manufacturer-provided protocol. In this study, we sought to determine the factors that introduced variability in daily quality assurance data. A phantom was scanned using a head coil in two schemes: with varied phantom placement daily, and with a single phantom placement, and evaluated over approximately 1 month. Minor placement and localization changes accounted for approximately 50% of the variability in the signal-to-noise ratios observed in these measures, driven by changes in the measured signal, while the noise remained constant. The changes in the signal-to-noise ratios were small over the 2-month study period.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [31] Application of synthetic data in the training of artificial intelligence for automated quality assurance in magnetic resonance imaging
    Tracey, John
    Moss, Laura
    Ashmore, Jonathan
    MEDICAL PHYSICS, 2023, 50 (09) : 5621 - 5629
  • [32] Metasurfaces provide a new way for building magnetic resonance imaging scanners
    Slobozhanyuk, Alexey P.
    Kivshar, Yuri S.
    Poddubny, Alexander N.
    Belov, Pavel A.
    2016 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2016, : 375 - 376
  • [33] Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging Tools for High-Quality Image Acquisition
    Shammi, Ummul Afia
    Delgado, Gabriela Maria Garcia
    Thomen, Robert
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (203):
  • [34] A Database of Electrocardiogram Signals acquired in different Magnetic Resonance Imaging Scanners
    Krug, Johannes W.
    Schmidt, Marcus
    Rose, Georg
    Friebe, Michael
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [35] Influence of imaging quality on magnetic resonance-based pressure gradient measurements
    Delles, Michael
    Rengier, Fabian
    Ley, Sebastian
    von Tengg-Kobligk, Hendrik
    Kauczor, Hans-Ulrich
    Unterhinninghofen, Roland
    Dillmann, Ruediger
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [36] Development of a temperature-controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements
    Jerome, Neil P.
    Papoutsaki, Marianthi-Vasiliki
    Orton, Matthew R.
    Parkes, Harold G.
    Winfield, Jessica M.
    Boss, Michael A.
    Leach, Martin O.
    deSouza, Nandita M.
    Collins, David J.
    MEDICAL PHYSICS, 2016, 43 (06) : 2998 - 3007
  • [37] A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners
    Tsekos, NV
    Özcan, A
    Christoforou, E
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (06): : 972 - 980
  • [38] Implementation of the Electronic Portal Imaging Device for Daily CyberKnife Quality Assurance
    Wang, L.
    Lo, A.
    Ho, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E327 - E327
  • [39] QUALITY ASSURANCE METHODS AND PHANTOMS FOR MAGNETIC-RESONANCE-IMAGING - REPORT OF AAPM NUCLEAR-MAGNETIC-RESONANCE TASK GROUP NO-1
    PRICE, RR
    AXEL, L
    MORGAN, T
    NEWMAN, R
    PERMAN, W
    SCHNEIDERS, N
    SELIKSON, M
    WOOD, M
    THOMAS, SR
    MEDICAL PHYSICS, 1990, 17 (02) : 287 - 295
  • [40] Quality Assurance Multicenter Comparison of Different MR Scanners for Quantitative Diffusion-Weighted Imaging
    Belli, Giacomo
    Busoni, Simone
    Ciccarone, Antonio
    Coniglio, Angela
    Esposito, Marco
    Giannelli, Marco
    Mazzoni, Lorenzo N.
    Nocetti, Luca
    Sghedoni, Roberto
    Tarducci, Roberto
    Zatelli, Giovanna
    Anoja, Rosa A.
    Belmonte, Gina
    Bertolino, Nicola
    Betti, Margherita
    Biagini, Cristiano
    Ciarmatori, Alberto
    Cretti, Fabiola
    Fabbri, Emma
    Fedeli, Luca
    Filice, Silvano
    Fulcheri, Christian P. L.
    Gasperi, Chiara
    Mangili, Paola A.
    Mazzocchi, Silvia
    Meliado, Gabriele
    Morzenti, Sabrina
    Noferini, Linhsia
    Oberhofer, Nadia
    Orsingher, Laura
    Paruccini, Nicoletta
    Princigalli, Goffredo
    Quattrocchi, Mariagrazia
    Rinaldi, Adele
    Scelfo, Danilo
    Freixas, Gloria Vilches
    Tenori, Leonardo
    Zucca, Ileana
    Luchinat, Claudio
    Gori, Cesare
    Gobbi, Gianni
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 213 - 219