A solution to measure the flow rate of wet gas

被引:1
|
作者
Niblett, Mark [1 ]
Robertson, Ian [1 ]
机构
[1] ABB Ltd, Workington, Cumbria, England
来源
MEASUREMENT & CONTROL | 2011年 / 44卷 / 02期
关键词
D O I
10.1177/002029401104400201
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Traditionally the mixture of fluids at the wellhead is separated into its various phases. Proper separation and accurate measurement of each of the component phases is critical in determining production capabilities. Gas is separated from the liquid by passing the emitted well fluids through a separator. The phases are then further separated and measured independently. Using a flowmeter rather than separators to determine the gas and liquid phases gives a very significant reduction in CAPEX in the evaluation of new wells. This paper covers the key benefits that wet gas meters provide in comparison with expensive separators, multiphase metering and traditional single phase DP producing devices such as orifice plates.
引用
收藏
页码:49 / 52
页数:4
相关论文
共 50 条
  • [31] Venturi Wet Gas Flow Modeling Based on Homogeneous and Separated Flow Theory
    Lide, Fang
    Tao, Zhang
    Ying, Xu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2008, 2008
  • [32] GAS FLOW-RATE METROLOGY
    MATTINGLY, GE
    1988 WORKSHOP AND SYMPOSIUM, TECHNICAL PRESENTATIONS : COMPETITIVENESS IN A WORLD MARKET, 1988, : 319 - 337
  • [33] Calculation of the gas flow rate in a microchannel
    T. G. Elizarova
    D. G. Ershov
    Moscow University Physics Bulletin, 2007, 62 (1) : 19 - 22
  • [34] METHOD TO MEASURE FLOW AND DURATION AS UNEMPLOYMENT RATE COMPONENTS
    WARREN, RS
    MONTHLY LABOR REVIEW, 1977, 100 (03) : 71 - 72
  • [35] ANOTHER MEASURE OF FLOW AND DURATION AS UNEMPLOYMENT RATE COMPONENTS
    THURSTON, L
    MONTHLY LABOR REVIEW, 1979, 102 (09) : 46 - 48
  • [36] A SIMPLIFIED METHOD TO MEASURE MAXIMAL EXPIRATORY FLOW RATE
    LANSING, PF
    DISEASES OF THE CHEST, 1965, 47 (05): : 509 - &
  • [37] COLLOID DISAPPEARANCE RATE AS A MEASURE OF LIVER BLOOD FLOW
    DOBSON, EL
    WARNER, GF
    JONES, HB
    FEDERATION PROCEEDINGS, 1952, 11 (01) : 35 - 35
  • [38] Noninvasive Flow Regime Identification for Wet Gas Flow Based on Flow-induced Vibration
    Hua Chenquan
    Wang Changming
    Geng Yanfeng
    Shi Tianming
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2010, 18 (05) : 795 - 803
  • [39] Numerical simulation of flow induced pulsation in a wet gas meter
    Gryzlov, A.
    Aure, R.
    Risdal, M.
    Breen, I.
    Steinsland, E.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2012) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2012), 2012, : 545 - 558
  • [40] Devices and methods for wet gas flow metering: A comprehensive review
    Salehi, Seyed Milad
    Lao, Liyun
    Xing, Lanchang
    Simms, Nigel
    Drahm, Wolfgang
    FLOW MEASUREMENT AND INSTRUMENTATION, 2024, 96