Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound

被引:5
|
作者
Amin, Sachin B. [1 ]
Mugele, Hendrik [1 ]
Dobler, Florian E. [1 ]
Marume, Kyohei
Moore, Jonathan P. [2 ]
Lawley, Justin S. [1 ]
机构
[1] Univ Innsbruck, Dept Sport Sci, Div Performance Physiol & Prevent, Furstenweg 185, A-6020 Innsbruck, Austria
[2] Bangor Univ, Sch Sport Hlth & Exercise Sci, Bangor, Gwynedd, Wales
来源
PHYSIOLOGICAL REPORTS | 2021年 / 9卷 / 19期
关键词
Doppler ultrasound; muscle blood flow; reliability; whole-body exercise; SMALL MUSCLE MASS; SKELETAL-MUSCLE; HEART-FAILURE; OXYGEN-UPTAKE; SHEAR-STRESS; TIME-COURSE; HUMANS; RESPONSES; CYCLE; SOFTWARE;
D O I
10.14814/phy2.15051
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Developing an exercise model that resembles a traditional form of aerobic exercise and facilitates a complete simultaneous assessment of multiple parameters within the oxygen cascade is critically for understanding exercise intolerances in diseased populations. Measurement of muscle blood flow is a crucial component of such a model and previous studies have used invasive procedures to determine blood flow kinetics; however, this may not be appropriate in certain populations. Furthermore, current models utilizing Doppler ultrasound use isolated limb exercise and while these studies have provided useful data, the exercise model does not mimic the whole-body physiological response to continuous dynamic exercise. Therefore, we aimed to measure common femoral artery blood flow using Doppler ultrasound during continuous dynamic stepping exercise performed at three independent workloads to assess the within day and between-day reliability for such an exercise modality. We report a within-session coefficient of variation of 5.8% from three combined workloads and a between-day coefficient of variation of 12.7%. These values demonstrate acceptable measurement accuracy and support our intention of utilizing this noninvasive exercise model for an integrative assessment of the whole-body physiological response to exercise in a range of populations.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):
  • [22] Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study
    del Mar Ruiz-Herrera, Maria
    Marcos-Tejedor, Felix
    Aldana-Caballero, Alberto
    Calvo-Lobo, Cesar
    Rodriguez-Sanz, David
    Moroni, Simone
    Konschake, Marko
    Mohedano-Moriano, Alicia
    Aceituno-Gomez, Javier
    Criado-alvarez, Juan Jose
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [23] Measurement of glenohumeral joint translation using real-time ultrasound imaging: A physiotherapist and sonographer intra-rater and inter-rater reliability study
    Rathi, Sangeeta
    Taylor, Nicholas F.
    Gee, Jamie
    Green, Rodney A.
    MANUAL THERAPY, 2016, 26 : 110 - 116
  • [24] Test-retest reliability of Doppler ultrasound-based leg blood flow assessments during exercise in patients with chronic obstructive pulmonary disease
    Mohammad, Milan
    Hartmann, Jacob P.
    Andersen, Amalie B.
    Hartmeyer, Helene L.
    Iepsen, Ulrik W.
    Berg, Ronan M. G.
    EXPERIMENTAL PHYSIOLOGY, 2024,
  • [25] Inter- and Intra-Rater Reliability of Ultrasound Measurements of Superficial and Deep Fasciae Thickness in Upper Limb
    Pirri, Carmelo
    Pirri, Nina
    Porzionato, Andrea
    Boscolo-Berto, Rafael
    De Caro, Raffaele
    Stecco, Carla
    DIAGNOSTICS, 2022, 12 (09)
  • [26] Inter-rater, intra-rater, and test-retest reliability of photonumeric grading scales using photographs
    Korgavkar, K.
    Weinstock, M. A.
    Lee, K.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2017, 137 (05) : S29 - S29
  • [27] Intra-rater Reliability and Between-leg Deficits in Unilateral Jump Performance and Muscle Strength in Healthy Controls
    Holsgaard-Larsen, Anders
    Andersen, Tanja
    Jensen, Carsten
    Aagaard, Per
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 624 - 625
  • [28] Assessing the effectiveness of Compare Assistant for improving intra-rater reliability of ultrasound-measured muscle thickness
    Baer, Tyler D.
    Rice, Kevin A.
    Urbina, Emely
    Whitener, Dominic V.
    Dankel, Scott J.
    JOURNAL OF MEDICAL ULTRASONICS, 2024, 51 (01) : 117 - 123
  • [29] Assessing the effectiveness of Compare Assistant for improving intra-rater reliability of ultrasound-measured muscle thickness
    Tyler D. Baer
    Kevin A. Rice
    Emely Urbina
    Dominic V. Whitener
    Scott J. Dankel
    Journal of Medical Ultrasonics, 2024, 51 : 117 - 123
  • [30] Ultrasound Video Recordings Enable Intra-rater Reliability of Muscle Size Measurements of the Toe Flexor Muscles
    Myrer, Joseph W.
    Ridge, Sarah T.
    deVries, Tiffany D.
    Johnson, A. Wayne
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 95 - 95