Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model

被引:55
|
作者
Mahar, Andrew [1 ,2 ]
Tamborlane, Jeffrey [2 ,3 ]
Oka, Richard [1 ]
Esch, James [2 ,3 ,4 ]
Pedowitz, Robert A. [5 ]
机构
[1] Rady Childrens Hosp San Diego, Dept Orthoped, San Diego, CA 92123 USA
[2] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92103 USA
[3] San Diego Arthroscopy & Sports Med Fellowship, San Diego, CA USA
[4] Tri City Orthopaed, Oceanside, CA USA
[5] Univ S Florida, Dept Orthopaed Surg, Tampa, FL USA
关键词
arthroscopic rotator cuff repair; double row; single-tendon tear; suture anchors; biomechanical stability;
D O I
10.1016/j.arthro.2007.07.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine biomechanical differences in cyclic elongation and ultimate strength between double-row rotator cuff repair and single-row repair for partial rotator cuff repairs. Methods: We randomly assigned 18 immature bovine specimens (aged 12 to 16 weeks) to 3 repair groups (6 per group). A 1 X 2-cm defect was created at the infraspinatus tendon insertion site. Two suture anchors were implanted 1 cm apart at the anatomic insertion area for the lateral row. Two suture anchors were implanted 1 cm medial to the lateral row and 1 cm apart from each other for the medial row. Repair groups were constructed as follows: single-row repair with double-loaded suture anchors (group 1), double-row repair with single-loaded medial row and double-loaded lateral row (group 2), and double-row repair with single-loaded medial row and single-loaded lateral row (group 3). Specimens were cyclically loaded from 10 N to 90 N for 500 cycles and then loaded at 0.5 mm/s to failure. Data for cyclic elongation, with loads at 3 mm, 5 mm, and 10 mm, were analyzed via a 1-way analysis of variance (P < .05). Results: There were no significant differences for peak elongation after cyclic loading between groups. There were no significant differences between repair groups for loads at 3 mm, 5 mm, and 10 mm of elongation. Constructs typically failed by knot slippage (83%), with a single sample having tendon-suture failure (17%). Conclusions;; Double-row repair did not show a biomechanical advantage compared with single-row repair. With this result in mind, the theoretic advantage of a potentially larger footprint must be balanced against the added surgical time, complexity, and cost of double-row repair. Clinical Relevance: Arthroscopic surgeons should choose the best form of fixation for a given patient, without undue emphasis on single-row repair versus double-row repair. The clinical and biologic impact of footprint restoration was not addressed in this study.
引用
收藏
页码:1265 / 1270
页数:6
相关论文
共 50 条
  • [41] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    M. H. Baums
    G. H. Buchhorn
    G. Spahn
    B. Poppendieck
    W. Schultz
    H.-M. Klinger
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 1052 - 1060
  • [42] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    Baums, M. H.
    Buchhorn, G. H.
    Spahn, G.
    Poppendieck, B.
    Schultz, W.
    Klinger, H. -M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (11) : 1052 - 1060
  • [43] Outcomes of Double-Row Rotator Cuff Repair Using a Novel All-Suture Soft Anchor Medial Row
    Loeb, Alexander E.
    Ostrander, Brook
    Ithurburn, Matthew P.
    Fleisig, Glenn S.
    Arceo, Cristian
    Brockington, David
    Tatum, Robert
    Feldman, John J.
    Ryan, Michael K.
    Rothermich, Marcus A.
    Emblom, Benton A.
    Dugas, Jeffrey R.
    Cain, E. Lyle
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (08)
  • [44] Clinical Outcome and Imaging of Arthroscopic Single-Row and Double-Row Rotator Cuff Repair: A Prospective Randomized Trial
    Ma, Hsiao-Li
    Chiang, En-Rung
    Wu, Hung-Ta H.
    Hung, Shih-Chieh
    Wang, Shih-Tein
    Liu, Chien-Lin
    Chen, Tain-Hsiung
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (01): : 16 - 24
  • [45] Comparison of arthroscopic single-row and double-row repair in the treatment of rotator cuff tears A protocol of cohort analysis
    Lin, Yanming
    Zhao, Jiasong
    Qiu, Heng
    Huang, Yong
    MEDICINE, 2020, 99 (29) : E21030
  • [46] A Multicenter Randomized Controlled Trial Comparing Single-Row with Double-Row Fixation in Arthroscopic Rotator Cuff Repair
    Lapner, Peter L. C.
    Sabri, Elham
    Rakhra, Kawan
    McRae, Sheila
    Leiter, Jeff
    Bell, Kimberly
    MacDonald, Peter
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (14): : 1249 - 1257
  • [47] Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears
    Zhang Chun-gang
    Zhao De-wei
    Wang Wei-ming
    Ren Ming-fa
    Li Rui-xin
    Yang Sheng
    Liu Yu-peng
    CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 3049 - 3054
  • [48] The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique
    Lafosse, Laurent
    Brozska, Roman
    Toussaint, Bruno
    Gobezie, Reuben
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (07): : 1533 - 1541
  • [49] The Outcome and Structural Integrity of Arthroscopic Rotator Cuff Repair with Use of the Double-Row Suture Anchor Technique
    Lafosse, Laurent
    Brzoska, Roman
    Toussaint, Bruno
    Gobezie, Reuben
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 275 - 286
  • [50] Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair: A Meta-analysis of the Randomized Clinical Trials
    Sheibani-Rad, Shahin
    Giveans, M. Russell
    Arnoczky, Steven Paul
    Bedi, Asheesh
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (02): : 343 - 348