Ellipsometric study of refractive index anisotropy in porous silicon

被引:7
|
作者
Krzyzanowska, H [1 ]
Kulik, M [1 ]
Zuk, J [1 ]
机构
[1] Marie Curie Sklodowska Univ, Inst Phys, PL-20031 Lublin, Poland
关键词
ellipsometry; porous silicon; optical anisotropy;
D O I
10.1016/S0022-2313(98)00093-3
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Porous Si layers of different thicknesses were prepared by anodising p(+)-type Si substrates with a resistivity of 0.01 Omega cm. The porosity of the samples ranged from 23% to 62%. The refractive index values for the ordinary and extraordinary rays were determined by multiple angle of incidence ellipsometry, from which an optical anisotropy parameter varying from 13% to 20% was obtained. The porous Si layers were modelled as uniaxially anisotropic films on an isotropic substrate, with an optical axis perpendicular to the sample surface. The morphological anisotropy which is typical for the p(+) -type porous Si with a predominating cylindrical geometry is responsible for these optical properties. All the porous Si layers studied were found to be optically negative. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:183 / 186
页数:4
相关论文
共 50 条
  • [31] Structure and optical parameters of the system with porous silicon: ellipsometric study
    Odarych, VA
    Dacenko, OI
    Boltovec, MS
    Rudenko, OV
    Pasichnyj, VO
    INTERNATIONAL CONFERENCE ON OPTICAL DIAGNOSIS OF MATERIALS AND DEVICES FOR OPTO-, MICRO-, AND QUANTUM ELECTRONICS 1997, 1998, 3359 : 59 - 64
  • [32] Ellipsometric study of the adsorption of bovine serum albumin into porous silicon
    Tsargorodskaya, A
    Nabok, AV
    Ray, AK
    NANOTECHNOLOGY, 2004, 15 (05) : 703 - 709
  • [33] In-plane refractive-index anisotropy in porous silicon layers induced by polarized illumination during electrochemical etching
    Koyama, H
    JOURNAL OF APPLIED PHYSICS, 2004, 96 (07) : 3716 - 3720
  • [34] In-plane refractive-index anisotropy in porous silicon layers induced by polarized illumination during electrochemical etching
    Koyama, Hideki
    Journal of Applied Physics, 2004, 96 (07): : 3716 - 3720
  • [35] Ellipsometric characterization of nanocrystals in porous silicon
    Petrik, P.
    Fried, M.
    Vazsonyi, E.
    Lohner, T.
    Horvath, E.
    Polgar, O.
    Basa, P.
    Barsony, I.
    Gyulai, J.
    APPLIED SURFACE SCIENCE, 2006, 253 (01) : 200 - 203
  • [36] Ellipsometric ATR spectroscopy for measuring the infrared refractive index
    Roeseler, A.
    Korte, E. H.
    Journal of Parallel and Distributed Computing, 247 (02):
  • [37] The dependence of ellipsometric parameters Δ and Ψ on refractive index of superficial film
    Berdie, A. D.
    Berdie, A. A.
    Jitian, S.
    INTERNATIONAL CONFERENCE ON APPLIED SCIENCES, 2019, 477
  • [38] REFRACTIVE INDEX OF SILICON
    PRIMAK, W
    APPLIED OPTICS, 1971, 10 (04): : 759 - &
  • [39] Some characteristics of porous silicon (reflection, scattering, refractive index, microhardness)
    Sokolov, V. I.
    Shelykh, A. I.
    TECHNICAL PHYSICS LETTERS, 2008, 34 (03) : 196 - 198
  • [40] Determination of the effective refractive index of porous silicon/polymer composite films
    贾振红
    ChineseOpticsLetters, 2005, (10) : 54 - 56