Graphene based highly sensitive refractive index sensor using double split ring resonator metasurface

被引:23
|
作者
Patel, Shobhit K. [1 ,2 ]
Solanki, Nilesh [1 ]
Charola, Shreyas [1 ,3 ]
Parmar, Juveriya [1 ,4 ]
Zakaria, Rozalina [5 ]
Faragallah, Osama S. [6 ]
Eid, Mahmoud M. A. [7 ]
Rashed, Ahmed Nabih Zaki [8 ]
机构
[1] Marwadi Univ, Dept Elect & Commun Engn, Rajkot 360003, Gujarat, India
[2] Marwadi Univ, Dept Comp Engn AI & Big Data, Rajkot 360003, Gujarat, India
[3] Marwadi Univ, Dept Informat & Commun Technol, Rajkot, Gujarat, India
[4] Marwadi Univ, Dept Phys, Rajkot, Gujarat, India
[5] Univ Malaya, Fac Sci, Photon Res Ctr, Kaula Lampur, Malaysia
[6] Taif Univ, Coll Comp & Informat Technol, Dept Informat Technol, POB 11099, At Taif 21944, Saudi Arabia
[7] Taif Univ, Coll Engn, Dept Elect Engn, POB 11099, At Taif 21944, Saudi Arabia
[8] Menoufia Univ, Fac Elect Engn, Elect & Elect Commun Engn Dept, Menoufia 32951, Egypt
关键词
Sensor; Refractive index; Graphene; Sensitivity; Metasurface; SURFACE-PLASMON RESONANCE; FIBER; PERFORMANCE; BIOSENSORS;
D O I
10.1007/s11082-022-03600-3
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A micrometer highly sensitive refractive index sensor comprising of double split ring metallic resonator placed above graphene layer is proposed. The sensitivity of the refractive index sensor is measured for hemoglobin biomolecule concentrations. The sensitivity of 5000 nm/RIU (Refractive Index Unit) over hemoglobin biomolecule with a different refractive index ranging from 1.34 to 1.43 are analyzed. A numerical investigation is performed between wavelength range from 55 mu m to 95 mu m to measure the sensing performance of the sensor. The absorption response is analyzed for change in thickness of double split-ring resonator metasurface, substrate thickness, and ground plane thickness In addition that absorption response is also observed with the change in chemical potential (mu(c)) of graphene and with different angles of incidence. The absorption response in the structure in term of the electric field with four different wavelengths are also presented. The comparative analysis with previously published structures is also presented in this paper. The proposed refractive index sensor structure is used to sense the hemoglobin biomolecules have better performance in terms of sensitivity compared to all the other designs. Due to its simple structure and easy fabrication steps, the refractive index sensor could be a potential device to be used in medical and diagnostic applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A highly sensitive plasmonic refractive index sensor based on concentric triple ring resonator for cancer biomarker and chemical concentration detection
    Tathfif, Infiter
    Hassan, Md. Farhad
    Rashid, Kazi Sharmeen
    Yaseer, Ahmad Azuad
    Sagor, Rakibul Hasan
    OPTICS COMMUNICATIONS, 2022, 519
  • [22] Plasmonics based refractive index sensor based on square ring resonator
    Sharma, Yazusha
    Zafar, Rukhsar
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 3698 - 3701
  • [23] Highly sensitive differential Hexagonal Split Ring Resonator sensor for material characterization
    Buragohain, Akash
    Das, Gouree Shankar
    Beria, Yatish
    Al-Gburi, Ahmed Jamal Abdullah
    Kalita, Partha Protim
    Doloi, Trishna
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 363
  • [24] Highly sensitive plasmonic sensor with a coupled split-square-ring resonator
    Wu, J. J.
    Li, J. H.
    Ma, Y.
    Maeda, H.
    Ma, Y. Q.
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (09)
  • [25] A High-Performance Refractive Index Sensor Based on Fano Resonance in Si Split-Ring Metasurface
    Gui-Dong Liu
    Xiang Zhai
    Ling-Ling Wang
    Qi Lin
    Sheng-Xuan Xia
    Xin Luo
    Chu-Jun Zhao
    Plasmonics, 2018, 13 : 15 - 19
  • [26] A High-Performance Refractive Index Sensor Based on Fano Resonance in Si Split-Ring Metasurface
    Liu, Gui-Dong
    Zhai, Xiang
    Wang, Ling-Ling
    Lin, Qi
    Xia, Sheng-Xuan
    Luo, Xin
    Zhao, Chu-Jun
    PLASMONICS, 2018, 13 (01) : 15 - 19
  • [27] Multi-resonances terahertz refractive index sensor based on a ring with embedded split rings metasurface array
    Wang, Yuanli
    Huang, Yuanze
    Zhou, Guohua
    Bian, Qiang
    Tong, Yude
    Fu, Qin
    Feng, Shuai
    Du, Qingguo
    Li, Zhengying
    OPTICS COMMUNICATIONS, 2023, 545
  • [28] Encrypted and tunable graphene-based metasurface refractive index sensor
    Parmar, Juveriya
    Patel, Shobhit K.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2022, 64 (01) : 77 - 82
  • [29] Robust and high-performance plasmonic refractive index sensor based on graphene waveguide ring resonator
    Ho, Kum-Song
    Paek, Hyon-Kyong
    Im, Song-Jin
    Kim, Jong-Wu
    Kim, Song-Chon
    Kim, Un-Song
    Kim, Kum-Dong
    Song, Kil-Song
    PHYSICA B-CONDENSED MATTER, 2023, 663
  • [30] A Highly Accurate Refractive Index Sensor with Two Operation Modes Based on Photonic Crystal Ring Resonator
    Vakili, Mahsa
    Noori, Mina
    ANNALEN DER PHYSIK, 2019, 531 (07)