Performance Evaluation of a Regenerative Stormwater Conveyance System: Case Study in Knoxville, Tennessee

被引:5
|
作者
Thompson, J. [1 ]
Schwartz, J. S. [1 ]
Hathaway, J. M. [1 ]
机构
[1] Univ Tennessee, Dept Civil & Environm Engn, Knoxville, TN 37996 USA
关键词
Stormwater; Regenerative stormwater conveyances (RSC); Hydrology; Water quality; CALIBRATION; DESIGN;
D O I
10.1061/(ASCE)EE.1943-7870.0001744
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As communities throughout the world work to reduce the impacts of urban stormwater on receiving streams, new stormwater controls have been a welcome addition to the established suite of green infrastructure practices. One such innovative control is the regenerative stormwater conveyance (RSC), which has shown mixed performance based on a limited number of studies to date. In this study, an RSC was constructed in Knoxville, Tennessee, and monitored for water quality and hydrologic performance over a 16-month period. Although modest cumulative volume reductions (6% overall) were realized, performance was found to substantially vary by season. Specifically, during the growing season when vegetation is active and water tables are low, performance increased to a cumulative volume reduction of 29%. Although effluent pollutant concentrations (total suspended solids, ammonium, nitrate, phosphate, sulfate, copper, and zinc) were consistent with those reported in the literature, concentration reductions were limited, and performance only slightly improved when load reductions were considered (load reductions for all parameters ranged from -342% to 38%). This is predominately attributed to low inlet concentrations, and emphasizes the need to evaluate stormwater control effectiveness based on multiple criteria. The frequent export of total suspended solids at the site (-60% load reduction) also suggests that the pools were too shallow, and that optimization of this design feature is needed to minimize internal scour. This work emphasizes the influence of seasonal processes such as evapotranspiration, and antecedent site conditions such as water table elevation and soil saturation on RSC function. Specifically, the data indicate that performance of these systems is likely to be highest when the RSC's sandy media can drain between storms, allowing recuperation of storage volume. Additional research is needed to fully quantify RSC function and develop design criteria for RSCs under various site conditions.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A case study approach for developing a project performance evaluation system
    Cao, Qing
    Hoffman, James J.
    INTERNATIONAL JOURNAL OF PROJECT MANAGEMENT, 2011, 29 (02) : 155 - 164
  • [22] Performance and economic evaluation of a wind energy system: A case study
    Jadallah, Abdullateef A.
    Ibrahim, Thamir K.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (03) : 7365 - 7377
  • [23] Evaluation of the acoustic performance of a modular construction system: Case study
    Matoski, Adalberto
    Ribeiro, Rodrigo Scoczynski
    APPLIED ACOUSTICS, 2016, 106 : 105 - 112
  • [24] Performance evaluation of existing water supply system: a case study
    Mishra A.K.
    Sudarsan J.S.
    Suribabu C.R.
    Nithiyanantham S.
    International Journal of Energy and Water Resources, 2024, 8 (2) : 269 - 278
  • [25] FIELD PERFORMANCE EVALUATION OF A VENTILATION SYSTEM: A SWINE CASE STUDY
    Harmon, J. D.
    Brumm, M. C.
    Jacobson, L. D.
    Pohl, S. H.
    Stender, D. R.
    Stowell, R. R.
    APPLIED ENGINEERING IN AGRICULTURE, 2012, 28 (02) : 251 - 257
  • [26] Comprehensive performance evaluation of stormwater management measures for sponge city construction: A case study in Gui'an New District, China
    Yao, Yichen
    Hu, Caihong
    Liu, Chengshuai
    Yang, Fan
    Ma, Bingyan
    Wu, Qiang
    Li, Xinan
    Soomro, Shan-e-hyder
    JOURNAL OF FLOOD RISK MANAGEMENT, 2022, 15 (04):
  • [27] STUDY OF THE PERFORMANCE COEFFICIENT OF AN ACTIVE MAGNETIC REGENERATIVE REFRIGERATION SYSTEM
    Meddeb, Z.
    Bchiri, D.
    Sidhom, R.
    Chrigui, M.
    Jeday, M. R.
    7TH INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2016, : 51 - 54
  • [28] A Rule-Based System for Human Performance Evaluation: A Case Study
    Mikulic, Iva
    Lisjak, Dragutin
    Stefanic, Nedeljko
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [29] Design and Performance Evaluation of a Solar Water Pumping System: A Case Study
    Elrefai, Mustafa
    Hamdy, Ragi A.
    ElZawawi, Amr
    Hamad, Mostafa S.
    PROCEEDINGS OF 2016 EIGHTEENTH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2016, : 914 - 920
  • [30] System architecture evaluation using modular performance analysis: a case study
    Ernesto Wandeler
    Lothar Thiele
    Marcel Verhoef
    Paul Lieverse
    International Journal on Software Tools for Technology Transfer, 2006, 8 (6) : 649 - 667