Effect of Varying Viscosity on Two-Fluid Model of Blood Flow through Constricted Blood Vessels: A Comparative Study

被引:20
|
作者
Tiwari, Ashish [1 ]
Chauhan, Satyendra Singh [1 ]
机构
[1] Birla Inst Technol & Sci Pilani, Dept Math, Pilani 333031, Rajasthan, India
关键词
Two-fluid model; Steady and pulsatile flow; Herschel-Bulkley fluid; Time-dependent constriction; Variable viscosity; NON-NEWTONIAN FLUID; PULSATILE FLOW; CASSON FLUID; CATHETERIZED ARTERY; STENOSED ARTERIES; BODY ACCELERATION; UNSTEADY-FLOW; RESISTANCE;
D O I
10.1007/s13239-018-00379-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeMost of the previously studied non-Newtonian blood flow models considered blood viscosity to be constant but for correct measurement of flow rate and flow resistance, the hematocrit dependent viscosity will be better as various literature suggested the variable nature of blood viscosity. Present work concerns the steady and pulsatile nature of blood flow through constricted blood vessels. Two-fluid model for blood is considered with the suspension of all the RBCs (erythrocytes) in the core region as a non-Newtonian (Herschel-Bulkley) fluid and the plasma in the cell free region near wall as a Newtonian fluid. No slip condition on the wall and radially varying viscosity has been taken.MethodsFor steady flow the analytical approach has been taken to obtain the exact solution. Regular perturbation expansion method has been used to solve the governing equations for pulsatile flow up to first order of approximation by assuming the pulsatile Reynolds number to be very small (much less than unity).ResultsFlow rate, wall shear stress and velocity profile have been graphically analyzed and compared with constant viscosity model. A noteworthy observation of the present study is that rise in viscosity index leads to decay in velocity, velocity of plug flow region, flow rate while flow resistance increases with rising viscosity index (m). The results for Power-law fluid (PL), Bingham-plastic fluid (BP), Newtonian fluid (NF) are found as special cases from this model. Like the constant viscosity model, it has been also observed that the velocity, flow rate and plug core velocity of two-fluid model are higher than the single-fluid model for variable viscosity.ConclusionsThe two-phase fluid model is more significant than the single-fluid model. Effect of viscosity parameter on various hemodynamical quantities has been obtained. It is also concluded that a rising viscosity parameter (varying nature of viscosity) significantly distinguishes the single and two-fluid models in terms of changes in blood flow resistance. The outcome of present study may leave a significant impact on analyzing blood flow through small blood vessels with constriction, where correct measurement of flow rate and flow resistance for medical treatment is very important.
引用
收藏
页码:155 / 172
页数:18
相关论文
共 50 条
  • [31] Mathematical Analysis of Carreau Fluid model for Blood Flow in Tapered Constricted Arteries
    Sankar, D. S.
    Lee, Usik
    Nagar, Atulya K.
    Morsidi, Maziri
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND TECHNOLOGY (ICAST'18), 2018, 2016
  • [32] A study of pulsatile blood flow modeled as a power law fluid in a constricted tube
    Prakash, J.
    Ogulu, A.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2007, 34 (06) : 762 - 768
  • [33] Study of blood flow in several benchmark micro-channels using a two-fluid approach
    Wu, Wei-Tao
    Yang, Fang
    Antaki, James F.
    Aubry, Nadine
    Massoudi, Mehrdad
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2015, 95 : 49 - 59
  • [34] Numerical Study of Two Dimensional Steady Incompressible Newtonian Laminar Flow of Blood Through Constricted Artery
    Tsetimi, Jonathan
    Mamadu, Ebimene
    EUROPEAN JOURNAL OF PURE AND APPLIED MATHEMATICS, 2022, 15 (01): : 314 - 327
  • [35] PARTICLE-FLUID SUSPENSION MODEL OF BLOOD-FLOW THROUGH STENOTIC VESSELS WITH APPLICATIONS
    SRIVASTAVA, VP
    INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1995, 38 (02): : 141 - 154
  • [36] FLOW OF COUPLE STRESS FLUID THROUGH STENOTIC BLOOD-VESSELS
    SRIVASTAVA, LM
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 479 - 485
  • [37] A two-fluid model for refrigerant flow through adiabatic capillary tubes
    Seixlack, Andre Luiz
    Prata, Alvaro Toubes
    Melo, Claudio
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2014, 36 (01) : 1 - 12
  • [38] A two-fluid model for refrigerant flow through adiabatic capillary tubes
    André Luiz Seixlack
    Álvaro Toubes Prata
    Cláudio Melo
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2014, 36 : 1 - 12
  • [39] EFFECT OF COLLATERAL ARTERY IMPAIRMENT ON BLOOD FLOW THROUGH A CONSTRICTED CAROTID ARTERY
    YOUMANS, JR
    KINDT, GW
    CIRCULATION, 1967, 36 (4S2) : I276 - &
  • [40] Two-fluid flow of blood in a curved stenotic artery under pulsating condition
    Shabbir, Muhammad Shahzad
    Hussain, Meriyem
    JOURNAL OF BIOLOGICAL PHYSICS, 2025, 51 (01)