Detection of occult atrial fibrillation in patients with embolic stroke of uncertain source: a work in progress

被引:20
|
作者
Andrade, Jason G. [1 ,2 ]
Field, Thalia [3 ]
Khairyl, Paul [1 ]
机构
[1] Univ Montreal, Montreal Heart Inst, Dept Med, Elect Serv, Montreal, PQ, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Dept Med, Div Neurol, Vancouver, BC V5Z 1M9, Canada
关键词
atrial fibrillation; stroke; implantable cardiac monitor; loop recorder; thromboembolism; ACUTE ISCHEMIC-STROKE; FOLLOW-UP STRATEGIES; CRYPTOGENIC STROKE; AMBULATORY ELECTROCARDIOGRAPHY; CATHETER ABLATION; RISK; ECG; DURATION; EVENTS; TIA;
D O I
10.3389/fphys.2015.00100
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Atrial fibrillation accounts for a substantial proportion of ischemic strokes of known etiology and may be responsible for an additional subset of the 25-40% of strokes of unknown cause (so-called cryptogenic). Oral anticoagulation is significantly more effective than antiplatelet therapy in the secondary prevention of atrial fibrillation-related strokes, providing justification for developing more sensitive approaches to detecting occult paroxysms of atrial fibrillation. In this article, we summarize the current state of knowledge regarding the value of in-hospital and out-patient monitoring for detecting atrial fibrillation in the context of cryptogenic stroke. We review the evidence for and against screening with standard Holter monitors, external loop recorders, the newer real-time continuous attended cardiac monitoring systems, cardiac implantable electronic devices, and insertable loop recorders. We review key questions regarding prolonged cardiac arrhythmia monitoring, including the relationship between duration of the atrial fibrillation episode and risk of thromboembolism, frequency of monitoring and its impact on the diagnostic yield in detecting occult or subclinical atrial fibrillation, and the temporal proximity of device-detected atrial fibrillation to stroke events. We conclude by proposing avenues for further research.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Early detection of occult atrial fibrillation and stroke prevention
    Keach, Joseph Walker
    Bradley, Steven M.
    Turakhia, Mintu P.
    Maddox, Thomas M.
    HEART, 2015, 101 (14) : 1097 - 1102
  • [32] Embolic stroke of undetermined source correlates to atrial fibrosis without atrial fibrillation
    Tandon, Karman
    Tirschwell, David
    Longstreth, W. T., Jr.
    Smith, Bryn
    Akoum, Nazem
    NEUROLOGY, 2019, 93 (04) : E381 - E387
  • [33] Is the left atrium the only embolic source in ischemic stroke patients with nonvalvular atrial fibrillation?
    Okura, H
    Inoue, H
    Tomon, M
    Nishiyama, S
    Yoshikawa, T
    Yoshida, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (10): : 1259 - +
  • [34] Predicting the Propensity of Atrial Cardiopathy and Paroxysmal Atrial Fibrillation in Patients with Embolic Stroke of Undetermined Source (ESUS)
    Elbarbary, Mohammed
    Kishk, Ahmed
    Abdeldayem, Mohamed E.
    Khalil, Mohamed A.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2025, 122 (01)
  • [35] Association of Global Cardiac Calcification with Atrial Fibrillation and Recurrent Stroke in Patients with Embolic Stroke of Undetermined Source
    Li, Tony Y. W.
    Yeo, Leonard L. L.
    Ho, Jamie S. Y.
    Leow, Aloysius S.
    Chan, Mark Y.
    Dalakoti, Mayank
    Chan, Bernard P. L.
    Seow, Swee-Chong
    Kojodjojo, Pipin
    Sharma, Vijay K.
    Tan, Benjamin Yong-Qiang
    Sia, Ching-Hui
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2021, 34 (10) : 1056 - 1066
  • [36] TIMING AND YIELD OF ATRIAL FIBRILLATION DETECTION BY IMPLANTABLE LOOP RECORDERS IN EMBOLIC STROKE OF UNDETERMINED SOURCE
    Campbell, Courtney
    Foreman, Beth
    Sosh, Daniel L.
    Carter, Rebecca
    Lee, Vivien H.
    Orsinelli, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 445 - 445
  • [37] Detection of Atrial Fibrillation after an embolic Stroke of unknown Cause
    Hasun, M.
    Winkler, W. -B.
    Sommer, P.
    Neuhold, C.
    Keller, H.
    Prainer, C.
    Schlager, T.
    Krichmayr, M.
    Fertl, E.
    Weidinger, F.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 52 - 53
  • [38] Atrial cardiopathy predicts detection of atrial fibrillation in embolic stroke of undetermined source: real-life data
    Silva, Ana Rita
    Pires, Carla
    Meira-Carvalho, Filipa
    Santos, Mariana
    Antunes, Nuno Pimenta
    Alves, Jose Nuno
    Ferreira, Carla
    Pinho, Joao
    NEUROLOGICAL SCIENCES, 2022, 43 (04) : 2383 - 2386
  • [39] Atrial cardiopathy predicts detection of atrial fibrillation in embolic stroke of undetermined source: real-life data
    Ana Rita Silva
    Carla Pires
    Filipa Meira-Carvalho
    Mariana Santos
    Nuno Pimenta Antunes
    José Nuno Alves
    Carla Ferreira
    João Pinho
    Neurological Sciences, 2022, 43 : 2383 - 2386
  • [40] Insertable cardiac monitors for detection of atrial fibrillation in patients with embolic stroke of undetermined source (ESUS) selected by risk factors
    Goetz, N.
    Poli, S.
    Haertig, F.
    Bauer, A.
    Duckheim, M.
    Eick, C.
    Schreieck, J.
    Gawaz, M.
    Ziemann, U.
    Meyer-Zurn, C. S.
    EUROPEAN HEART JOURNAL, 2015, 36 : 988 - 988