Techno-economic analysis of a coal-fired CHP based combined heating system with gas-fired boilers for peak load compensation

被引:42
|
作者
Wang, Hai-Chao [1 ,2 ]
Jiao, Wen-Ling [1 ]
Lahdelma, Risto [2 ]
Zou, Ping-Hua [1 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Peoples R China
[2] Aalto Univ, Dept Energy Technol, Sch Engn, FI-00076 Aalto, Finland
关键词
Techno-economic analysis; Combined heat and power; Combined heating system; ECONOMIC-ANALYSIS; NATURAL-GAS; ENERGY; MODEL; OPTIMIZATION; RENOVATION; SIMULATION; ALGORITHM; SECTOR;
D O I
10.1016/j.enpol.2011.09.050
中图分类号
F [经济];
学科分类号
02 ;
摘要
Combined heat and power (CHP) plants dominate the heating market in China. With the ongoing energy structure reformation and increasing environmental concerns, we propose gas-fired boilers to be deployed in underperforming heating substations of heating networks for peak load compensation, in order to improve both energy efficiency and environmental sustainability. However, due to the relatively high price of gas, techno-economic analysis is required for evaluating different combined heating scenarios, characterized by basic heat load ratio (beta). Therefore, we employ the dynamic economics and annual cost method to develop a techno-economic model for computing the net heating cost of the system, considering the current state of the art of cogeneration systems in China. The net heating cost is defined as the investment costs and operations costs of the system subtracted by revenues from power generation. We demonstrate the model in a real-life combined heating system of Daqing, China. The results show that the minimum net heating cost can be realized at beta=0.75 with a cost reduction of 16.8% compared to coal heating alone. Since fuel cost is the dominating factor, sensitivity analyses on coal and gas prices are discussed subsequently. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7950 / 7962
页数:13
相关论文
共 50 条
  • [31] Thermodynamic and techno-economic analysis of a novel compressed air energy storage system coupled with coal-fired power unit
    Shi, Xingping
    He, Qing
    Liu, Yixue
    An, Xugang
    Zhang, Qianxu
    Du, Dongmei
    ENERGY, 2024, 292
  • [32] Environmental impact of fuel for district heating system with gas-fired peak load boiler in secondary network
    Zheng Xue-jing
    You Shi-jun
    Dong Shu-yun
    Niu Run-ping
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 216 - 220
  • [33] Techno-Economic Analysis of CO2 Capture Processes from Coal-fired Power Plants
    Yun, Seokwon
    Lee, Sunghoon
    Kim, Jin-Kuk
    28TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2018, 43 : 1519 - 1520
  • [34] Rate-based simulation and techno-economic analysis of coal-fired power plants with aqueous ammonia carbon capture
    Bonalumi, Davide
    Lillia, Stefano
    Valenti, Gianluca
    ENERGY CONVERSION AND MANAGEMENT, 2019, 199
  • [35] A Liquid-Desiccant-Based Heat Recovery System for Gas-Fired Boilers in District Heating Networks
    Zhang, Xiaoyue
    Li, Zhen
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 410 - 417
  • [36] Techno-Economic Analysis of Natural Gas-Fired Microgrid for Electricity, Fresh Water, and Cold Storage in Rural Area
    Fuad, Muhammad Raihan
    Octavianthy, Desti
    Purwanto, Widodo Wahyu
    11TH REGIONAL CONFERENCE ON CHEMICAL ENGINEERING (RCCHE 2018), 2019, 2085
  • [37] TECHNO-ECONOMIC ASSESSMENT OF CARBON CAPTURE AND STORAGE FACILITIES COUPLED TO COAL-FIRED POWER PLANTS
    Zhang, Zhihua
    ENERGY & ENVIRONMENT, 2015, 26 (6-7) : 1069 - 1080
  • [38] Techno-economic assessment of carbon mitigation options for existing coal-fired power plants in India
    Singh, Udayan
    Rao, Anand B.
    5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER) 2015, 2016, 90 : 326 - 335
  • [39] Study on a novel district heating system combining clean coal-fired cogeneration with gas peak shaving
    Zhang, Shuyan
    Wang, Xiaolin
    Li, Yan
    Wang, Weiqin
    Li, Wentao
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [40] Energy efficiency analysis and optimization of coal-fired CHP based on low heat-load Triangle
    Wang, Lei
    Zhao, Jia-Ning
    Ding, Li-Qun
    Liao, Chun-Hui
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2012, 39 (04): : 70 - 74