Techno-economic analysis of a coal-fired CHP based combined heating system with gas-fired boilers for peak load compensation

被引:42
|
作者
Wang, Hai-Chao [1 ,2 ]
Jiao, Wen-Ling [1 ]
Lahdelma, Risto [2 ]
Zou, Ping-Hua [1 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Peoples R China
[2] Aalto Univ, Dept Energy Technol, Sch Engn, FI-00076 Aalto, Finland
关键词
Techno-economic analysis; Combined heat and power; Combined heating system; ECONOMIC-ANALYSIS; NATURAL-GAS; ENERGY; MODEL; OPTIMIZATION; RENOVATION; SIMULATION; ALGORITHM; SECTOR;
D O I
10.1016/j.enpol.2011.09.050
中图分类号
F [经济];
学科分类号
02 ;
摘要
Combined heat and power (CHP) plants dominate the heating market in China. With the ongoing energy structure reformation and increasing environmental concerns, we propose gas-fired boilers to be deployed in underperforming heating substations of heating networks for peak load compensation, in order to improve both energy efficiency and environmental sustainability. However, due to the relatively high price of gas, techno-economic analysis is required for evaluating different combined heating scenarios, characterized by basic heat load ratio (beta). Therefore, we employ the dynamic economics and annual cost method to develop a techno-economic model for computing the net heating cost of the system, considering the current state of the art of cogeneration systems in China. The net heating cost is defined as the investment costs and operations costs of the system subtracted by revenues from power generation. We demonstrate the model in a real-life combined heating system of Daqing, China. The results show that the minimum net heating cost can be realized at beta=0.75 with a cost reduction of 16.8% compared to coal heating alone. Since fuel cost is the dominating factor, sensitivity analyses on coal and gas prices are discussed subsequently. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7950 / 7962
页数:13
相关论文
共 50 条
  • [1] Technical and Economic Analysis of the Combined Heating System with a Coal-fired Basic Heat-source and Gas-fired Boilers as Peak Load Heat-sources
    Wang, Haichao
    Jiao, Wenling
    Liu, Jingcheng
    Zou, Pinghua
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1632 - 1639
  • [2] Gas-fired combined cooling, heating and power (CCHP) in Beijing: A techno-economic analysis
    Yan, Bofeng
    Xue, Song
    Li, Yuanfei
    Duan, Jinhui
    Zeng, Ming
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 63 : 118 - 131
  • [3] Analysis of household heating with gas-fired boilers
    Guo, Fei
    Jiang, Yi
    Tian, Guansan
    Nuantong Kongtiao/HV & AC, 2002, 32 (06):
  • [4] Optimization and techno-economic analysis of combined gas-fired boiler and solar heating system for capacity-increase cities
    Wang, Dengjia
    Chen, Ran
    Zhou, Yong
    Wang, Yingying
    Liu, Yanfeng
    SOLAR ENERGY, 2022, 243 : 225 - 235
  • [5] Economic analysis for district heating system with gas-fired peak load boiler in secondary network
    Zheng, Xuejing
    You, Shijun
    Zhu, Yanlin
    Niu, Runping
    Dong, Shuyun
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 161 - 164
  • [6] Study on the policy of replacing coal-fired boilers with gas-fired boilers for central heating based on the 3E system and the TOPSIS method: A case in Tianjin, China
    Zhao, Jing
    Duan, Yaoqi
    Liu, Xiaojuan
    ENERGY, 2019, 189
  • [7] Techno-Economic Analysis of Solar Tower Aided Coal-Fired Power Generation System
    Zhu, Yong
    Zhai, Rongrong
    Yang, Yongping
    Angel Reyes-Belmonte, Miguel
    ENERGIES, 2017, 10 (09):
  • [8] Value analysis of district heating system with gas-fired peak load boiler in secondary network
    郑雪晶
    穆振英
    JournalofCentralSouthUniversityofTechnology, 2009, 16(S1) (S1) : 178 - 182
  • [9] Value analysis of district heating system with gas-fired peak load boiler in secondary network
    Zheng Xue-jing
    Mu Zhen-ying
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 178 - 182
  • [10] Value analysis of district heating system with gas-fired peak load boiler in secondary network
    郑雪晶
    穆振英
    Journal of Central South University, 2009, 16 (S1) : 178 - 182