Micro-cantilever method for measuring the tensile strength of biofilms and microbial flocs

被引:54
|
作者
Poppele, EH [1 ]
Hozalski, RM [1 ]
机构
[1] Univ Minnesota, Dept Civil Engn, Minneapolis, MN 55455 USA
关键词
biofilm; cantilever; cohesion; floc; measurement; tensile strength;
D O I
10.1016/S0167-7012(03)00198-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cohesive strength is an important factor in determining the structure and function of biofilm systems, and cohesive strength plays a key role in our ability to remove or control biofilms in engineered systems. A micro-mechanical device has been developed to directly measure the tensile strength of biofilms and other microbial aggregates. An important feature of this method is the combination of a direct measurement of force with particle separations that occur at a scale comparable to that observed for biofilm systems. The force required to separate an aggregate is determined directly from the deflection of cantilevered glass micropipettes with a 20-40-mum diameter. Combined with an estimate of the cross-sectional area of the aggregate at the point of separation this measurement indicates the cohesive strength of the aggregate. Samples of return activated sludge (RAS) and a Pseudomonas aeruginosa biofilm were tested using the device. The measured cohesive strengths of the RAS floes ranged from 419 to 206,400 N/m(2), While many of the floes exceeded the range of measurement of the device. Fragments of P aeruginosa biofilm had cohesive strengths ranging from 395 to 15,640 N/m(2), with a median value of 3020 N/m(2). The median equivalent diameters of the particles detached from the aggregates were 32 mum for RAS and 30 gm for the P aeruginosa biofilms. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 50 条
  • [41] The spalling of long bars as a reliable method of measuring the dynamic tensile strength of ceramics
    Díaz-Rubio, FG
    Pérez, JR
    Gálvez, VS
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2002, 27 (02) : 161 - 177
  • [42] A new method for measuring RBA applied to the Page equation for the tensile strength of paper
    Batchelor, Warren
    Kibblewhite, R. Paul
    He, Jihong
    APPITA JOURNAL, 2008, 61 (04): : 302 - 306
  • [43] The influence of refractive index change on a micro-cantilever bio/chemical sensor system based on optical lever read-out method
    Huang, Yuan
    Liu, Hong
    Li, Kai
    Chen, Yanyun
    Zhang, Qingchuan
    Wu, Xiaoping
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (01) : 329 - 334
  • [44] Comment on "A method to measure cellular adhesion utilizing a polymer micro-cantilever" [Appl. Phys. Lett. 103, 123702 (2013)]
    Eibl, Robert H.
    APPLIED PHYSICS LETTERS, 2014, 104 (23)
  • [45] Drilling-Hole-Loading Method for Measuring Tensile strength of Irregular Small Stones
    Chen, Jin
    Liu, Ming
    Lu, Jiemin
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 649 - +
  • [46] Development of Micro Tensile Testing Method in an FIB System for Evaluating Grain Boundary Strength
    Fujii, Katsuhiko
    Fukuya, Koji
    MATERIALS TRANSACTIONS, 2011, 52 (01) : 20 - 24
  • [47] Response to "Comment on 'A method to measure cellular adhesion utilizing a polymer micro-cantilever'" [Appl. Phys. Lett. 104, 236103 (2014)]
    Gaitas, Angelo
    Malhotra, Ricky
    Pienta, Kenneth
    Kim, Gwangseong
    APPLIED PHYSICS LETTERS, 2014, 104 (23)
  • [48] A Non-contact measurement technique to measure micro surface stress and obtain deformation profiles of the order of 1nm in Micro-cantilever based structures by single image Optical Diffraction method
    Phani, Arindam
    PHOTONICS NORTH 2010, 2010, 7750
  • [49] A novel micro-tensile dentin bond strength method using paired dentin quarters.
    Geraldeli, S
    Perdigao, J
    Larson, WK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A416 - A416
  • [50] Measuring bone strength from in vivo micro-CT using the finite element method
    Boyd, Steven
    Macdonald, H. M.
    Hanley, D. A.
    BONE, 2008, 43 : S18 - S18