Linearization of second-order calibration curves in stable isotope dilution-mass spectrometry

被引:6
|
作者
Fay, LB [1 ]
Métairon, S [1 ]
Baumgartner, M [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
关键词
mass spectrometry; isotopic dilution; stable isotopes; internal standard; calibration; linearization; quantitation;
D O I
10.1002/ffj.971
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The quantification of compounds using isotope dilution mass spectrometry requires the establishment of calibration curves prior to determination of any unknown sample. When calibration over a wide concentration range is required and/or when an overlap exists between internal standard and analyte ions (if mono- or di-isotopically-labelled internal standards are used), second-order calibration curves are obtained. In this paper we have compared several calculation methods to linearize such calibration curves. We found that the method published by Bush and Trager(6) gives a satisfactory linear relationship between the corrected amount ratio y = Q(1)(Q(u) + tQ(1)) (the value Q(u) being the amount of unlabelled analyte, Q(1) the amount of labelled internal standard and t, the fixed fraction of the internal standard, which is identical to the unlabelled analyte) and the ratio of unlabelled to labelled ion intensities. All the other calculation methods that have been published so far have failed to linearize the second-order calibration curve build-up over a wide concentration range. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:164 / 168
页数:5
相关论文
共 50 条
  • [41] Second-order universal calibration
    Ghaffari, Mandiyeh
    Khoshayand, Mohammad Reza
    Duponchel, Ludovic
    Abdollahi, Hamid
    TALANTA, 2020, 212
  • [42] Double Calibration (External Calibration and Stable Isotope Dilution) for Determining Selenium in Plant Tissue by Hydride Generation Inductively Coupled Plasma Mass Spectrometry
    Zhang, Ling-Su
    Combs, Sherry M.
    Journal of AOAC International, 81 (05): : 1060 - 1064
  • [43] Double calibration (external calibration and stable isotope dilution) for determining selenium in plant tissue by hydride generation inductively coupled plasma mass spectrometry
    Zhang, LS
    Combs, SM
    JOURNAL OF AOAC INTERNATIONAL, 1998, 81 (05) : 1060 - 1064
  • [44] ISOTOPE DILUTION-MASS SPECTROMETRIC METHODS FOR ACCURATE DETERMINATIONS OF ORGANIC SERUM CONSTITUENTS
    WELCH, MJ
    COHEN, A
    HERTZ, HS
    SCHAFFER, R
    SNIEGOSKI, LT
    WHITE, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 165 - ANYL
  • [45] Advances in second-order calibration
    Kowalski, Bruce R., 1600, John Wiley and Sons Ltd (07):
  • [46] Analysis of serum bile acids by isotope dilution-mass spectrometry to assess the performance of routine total bile acid methods
    Ducroq, D. H.
    Morton, M. S.
    Shadi, N.
    Fraser, H. L.
    Strevens, C.
    Morris, J.
    Thomas, M. A.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 535 - 540
  • [49] Development of a high ratio isotope dilution mass spectrometry calibration technique for chemical metrology
    Hearn, R
    Evans, P
    Sargent, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (10) : 1019 - 1023
  • [50] Linearization of second-order superlinear oscillation theorems
    Agarwal, RP
    Grace, SR
    O'Regan, D
    MATHEMATICAL AND COMPUTER MODELLING, 2004, 39 (9-10) : 1165 - 1183