Feasibility study of using air as a contrast medium in MR colonography

被引:18
|
作者
So, NMC [1 ]
Lam, WWM
Mann, D
Leung, KL
Metreweli, C
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Fac Med, Dept Diagnost Radiol & Organ Imaging, Sha Tin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Fac Med, Dept Surg, Sha Tin, Hong Kong, Peoples R China
关键词
colon; magnetic resonance; colon neoplasms;
D O I
10.1016/S0009-9260(03)00126-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the feasibility of using air as intraluminal contrast medium in magnetic resonance (MR) colonography. MATERIALS AND METHODS: Twenty-two patients underwent MR colonography (MRC) using air before colonoscopy. All patients were imaged in prone and supine positions. Each colon was divided into five segments. Two radiologists reviewed the images for the degree of colonic distension, image quality and colonic lesions. The colonic lesions identified using MR were compared with those identified on colonoscopy. RESULTS: Eight men and 14 women with mean age of 55.5 years were studied. All patients completed the MR examination. One hundred and five out of 110 (95.5%) colonic segments were well distended in both prone and supine positions. Image quality was good in all cases. Colonoscopy detected 16 lesions: three greater than or equal to1 cm, one 7 mm lesion and 12 lesions less than or equal to5 mm. All lesions 1 cm or larger were detected by MRC. CONCLUSION: MRC using air and the single-shot half-Fourier rapid acquisition with refocused echos (RARE) technique is feasible. But in this small pilot study, it had low sensitivity for the detection of polyps less than 1 cm in diameter. (C) 2003 The Royal College of Radiologists. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 50 条
  • [31] Automated polyp detector for CT colonography: Feasibility study
    Summers, RM
    Beaulieu, CF
    Pusanik, LM
    Malley, JD
    Jeffrey, RB
    Glazer, DI
    Napel, S
    RADIOLOGY, 2000, 216 (01) : 284 - 290
  • [32] Partial preparation computed tomographic colonography: a feasibility study
    C. Daniel Johnson
    J. Scott Kriegshauser
    Jeffrey T. Lund
    Arthur D. Shiff
    Qing Wu
    Abdominal Imaging, 2011, 36 : 707 - 712
  • [33] Partial preparation computed tomographic colonography: a feasibility study
    Johnson, C. Daniel
    Kriegshauser, J. Scott
    Lund, Jeffrey T.
    Shiff, Arthur D.
    Wu, Qing
    ABDOMINAL IMAGING, 2011, 36 (06): : 707 - 712
  • [34] Functional imaging with MR T1 contrast: a feasibility study with blood-pool contrast agent
    Agata Majos
    Piotr Bogorodzki
    Ewa Piątkowska-Janko
    Tomasz Wolak
    Robert Kurjata
    Ludomir Stefańczyk
    European Radiology, 2009, 19 : 898 - 903
  • [35] Functional imaging with MR T1 contrast: a feasibility study with blood-pool contrast agent
    Majos, Agata
    Bogorodzki, Piotr
    Piatkowska-Janko, Ewa
    Wolak, Tomasz
    Kurjata, Robert
    Stefanczyk, Ludomir
    EUROPEAN RADIOLOGY, 2009, 19 (04) : 898 - 903
  • [36] Feasibility of using automated insufflated carbon dioxide (CO2) for luminal distension in 3.0 T MR colonography
    Zijta, F. M.
    Nederveen, A. J.
    Jensch, S.
    Florie, J.
    Bipat, S.
    van der Paardt, M. P.
    van Swijndregt, D. Montauban
    Stoker, J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) : 1128 - 1133
  • [37] CT colonography without cathartic preparation: Feasibility study
    Callstrom, MR
    Johnson, CD
    Fletcher, JG
    Reed, JE
    Ahlquist, DA
    Harmsen, WS
    Tait, K
    Wilson, LA
    Corcoran, KE
    RADIOLOGY, 2001, 219 (03) : 693 - 698
  • [38] Combined dynamic contrast enhanced breast MR and proton spectroscopic imaging: A feasibility study
    Jacobs, MA
    Barker, PB
    Argani, P
    Ouwerkerk, R
    Bhujwalla, ZM
    Bluemke, DA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) : 23 - 28
  • [39] Screening of colonic tumors by air-inflated magnetic resonance (MR) colonography
    Lam, WWM
    Leung, WK
    Wu, JKL
    Nina, MC
    Sung, JJY
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (04) : 447 - 452
  • [40] Suspicious contrast medium enhancement in dynamic MR mammography
    Fink, C
    Wasser, K
    Aufderstrasse, D
    Lüdemann, H
    Delorme, S
    RADIOLOGE, 2002, 42 (09): : 753 - 755