Validation of a Two-Phase CFD Air/Mist Film Cooling Model With Experimental Details-Part I: Development of an Experimental Test Facility

被引:4
|
作者
Wang, Ting [1 ]
Zhao, Lei [1 ]
Abdelmaksoud, Ramy [1 ]
机构
[1] Univ New Orleans, Energy Convers & Conservat Ctr, New Orleans, LA 70148 USA
关键词
film cooling; mist cooling; two-phase flow; droplets; gas turbine heat transfer; HEAT-TRANSFER COEFFICIENT; MASS-TRANSFER; IMPINGEMENT; TUBE;
D O I
10.1115/1.4054624
中图分类号
O414.1 [热力学];
学科分类号
摘要
Film cooling is a cooling technique widely used in high-performance gas turbines to protect the turbine airfoils from being damaged by hot flue gases. Motivated by the need to further improve the turbine hot section cooling performance, a mist/air film cooling scheme is investigated. A small amount of tiny water droplets with an average diameter of about 7 mu m (mist) is injected into the cooling air to enhance the cooling performance. One key feature in understanding mist cooling is the ability to capture droplet information. In order to thoroughly investigate a two-phase flow, experimental and computational studies are needed. Designing an experimental setup for a two-phase flow experiment is challenging, therefore, the authors will dedicate this paper as Part I to discuss all the challenges faced in order to create a successful experimental facility for air/mist film cooling while Part II will discuss how to conduct a high-fidelity computational model for air/mist film cooling accompanied with a validation study by including detailed experimental conditions. This paper presents the experimental facility and instrumentation of an air/mist film cooling study with both heat transfer and droplet measurements. A wind tunnel system and test facilities are built. A phase doppler particle analyzer (PDPA) system is employed to measure the two-phase flow characteristics, including droplet size, droplet dynamics, velocity, and turbulence. An infrared camera and thermocouples are both used for temperature measurements. An extensive uncertainty analysis is performed to assist in identifying large uncertainty sources and planning for an experimental procedure. It was found during the experiment design process that resolving the mist agglomeration problem is the key in successfully generating a well-controlled mist/air mixture and reducing experimental uncertainties. The test apparatus has proven to serve the purpose well to investigate mist/air film cooling with both heat transfer and droplet measurements. Selected experimental data are presented.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Experimental study of an air-source heat pump for simultaneous heating and cooling - Part 2: Dynamic behaviour and two-phase thermosiphon defrosting technique
    Byrne, Paul
    Miriel, Jacques
    Lenat, Yves
    APPLIED ENERGY, 2011, 88 (09) : 3072 - 3078
  • [42] Optimizing the design for a two-phase cooling loop heat pipe Part A: Numerical model, validation and application to a case study
    Esarte, J.
    Bernardini, A.
    Blanco, J. M.
    Sancibrian, R.
    APPLIED THERMAL ENGINEERING, 2016, 99 : 892 - 904
  • [43] Modeling the forced-air cooling process of fresh strawberry packages, Part III: Experimental validation of the energy model
    Ferrua, M. J.
    Singh, R. P.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (02): : 359 - 368
  • [44] Modeling the forced-air cooling process of fresh strawberry packages, Part II: Experimental validation of the flow model
    Ferrua, M. J.
    Singh, R. P.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (02): : 349 - 358
  • [45] Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
    Rivetti, A.
    Angarita, G.
    Angulo, M.
    Botero, F.
    Liscia, S.
    30TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS (IAHR 2020), 2021, 774
  • [46] Validation of the generalized model of two-phase thermosyphon loop based on experimental measurements of volumetric flow rate
    Bielinski, Henryk
    ARCHIVES OF THERMODYNAMICS, 2016, 37 (03) : 109 - 138
  • [47] Simulation model for complex refrigeration systems based on two-phase fluid network - Part I: Model development
    Shao, Shuangquan
    Shi, Wenxing
    Li, Xianting
    Yan, Qisen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03): : 490 - 499
  • [48] Low Pressure Experimental Validation of Low-Dimensional Analytical Model for Air-Water Two-Phase Transient Flow in Horizontal Pipelines
    Mnasri, Hamdi
    Meziou, Amine
    Franchek, Matthew A.
    Loh, Wai Lam
    Wan, Thiam Teik
    Tam, Nguyen Dinh
    Wassar, Taoufik
    Tang, Yingjie
    Grigoriadis, Karolos
    FLUIDS, 2021, 6 (06)
  • [49] Pharmacophore-based discovery of FXR agonists. Part I: Model development and experimental validation
    Schuster, Daniela
    Markt, Patrick
    Grienke, Ulrike
    Mihaly-Bison, Judit
    Binder, Markus
    Noha, Stefan M.
    Rollinger, Judith M.
    Stuppner, Hermann
    Bochkov, Valery N.
    Wolber, Gerhard
    BIOORGANIC & MEDICINAL CHEMISTRY, 2011, 19 (23) : 7168 - 7180
  • [50] Two-phase mini-thermosyphon electronics cooling: Dynamic modeling, experimental validation and application to 2U servers
    Lamaison, Nicolas
    Ong, Chin Lee
    Marcinichen, Jackson B.
    Thome, John R.
    APPLIED THERMAL ENGINEERING, 2017, 110 : 481 - 494