Multi-pole magnets to focus an O2 sheet beam for a non-destructive beam-profile monitor

被引:11
|
作者
Fujisawa, T
Hashimoto, Y
Morimoto, T
Fujita, Y
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
关键词
O-2 sheet beam; multi-pole magnets; magnetic moment; spin; beam profile;
D O I
10.1016/S0168-9002(03)01393-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An oxygen molecular sheet beam was generated using the nozzle beam method, focused with multi-pole magnets, and was then used as the target of a non-destructive beam-profile monitor. The method used for focusing the sheet beam with multi-pole magnets is based on the fact that an oxygen molecule has a magnetic moment as large as two Bohr magnetons and a spin of 1. Using focusing magnets, the density of an oxygen sheet beam at the median plane increased up to about twice compared with the value obtained without focusing magnets. The principle of focusing and the focusing multi-pole magnets have been studied. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 26 条
  • [21] Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples
    Mikhail Lyubomirskiy
    Felix Wittwer
    Maik Kahnt
    Frieder Koch
    Adam Kubec
    Ken Vidar Falch
    Jan Garrevoet
    Martin Seyrich
    Christian David
    Christian G. Schroer
    Scientific Reports, 12
  • [22] Anisotropic Si deep beam etching with profile control using SF6/O2 Plasma
    Zou, H
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2004, 10 (8-9): : 603 - 607
  • [23] First demonstration of non-destructive tests on tungsten-coated JET divertor CFC tiles in the electron beam facility JUDITH-2
    Schmidt, A.
    Hirai, T.
    Keusemann, S.
    Roedig, M.
    Pintsuk, G.
    Linke, J.
    Maier, H.
    Riccardo, V.
    Matthews, G. F.
    Hill, M.
    Altmann, H.
    PHYSICA SCRIPTA, 2009, T138
  • [24] Performance assessment of a newly developed non-invasive 2D beam profile monitor for high-intensity accelerators
    Rosily, Sherry
    Prasad, M. Hari
    Dikshit, Biswaranjan
    Krishnagopal, Srinivas
    Kumar, Rajesh
    JOURNAL OF INSTRUMENTATION, 2024, 19 (06):
  • [25] An X-ray fluorescence and machine learning based methodology for the direct non-destructive compositional analysis of (Th1-xUx)O2 fuel pellets
    Kanrar, Buddhadev
    Sanyal, Kaushik
    Sarkar, Arnab
    Pai, Rajesh V.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (09) : 1841 - 1850
  • [26] Non-destructive determination of uranium and plutonium in annular (U, Pu)O2 mixed oxide sintered pellets by wavelength dispersive X-ray fluorescence spectrometry
    A. Pandey
    F. A. Khan
    A. Kelkar
    P. Purohit
    Pradeep Kumar
    Vijay Kumar
    D. B. Sathe
    R. B. Bhatt
    P. G. Behere
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 326 : 423 - 433