Strengths and Weaknesses of 1.5T and 3T MRS Data in Brain Glioma Classification

被引:11
|
作者
Kounelakis, M. G. [1 ]
Dimou, I. N. [1 ]
Zervakis, M. E. [1 ]
Tsougos, I. [2 ]
Tsolaki, E. [2 ]
Kousi, E. [2 ]
Kapsalaki, E. [2 ]
Theodorou, K. [2 ]
机构
[1] Tech Univ Crete, Dept Elect & Comp Engn, Khania 73100, Greece
[2] Univ Thessaly, Dept Med Sci, Larisa 41110, Greece
关键词
Brain glioma discrimination; metabolic ratio markers; 1.5T and 3T magnetic resonance spectroscopy (MRS) scanners; MAGNETIC-RESONANCE-SPECTROSCOPY; TUMOR CLASSIFICATION; CEREBRAL GLIOMAS; ASTROCYTOMAS; EXPERIENCE; SPECTRA; LESIONS;
D O I
10.1109/TITB.2011.2131146
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Although magnetic resonance spectroscopy (MRS) methods of 1.5Tesla (T) and 3T have been widely applied during the last decade for noninvasive diagnostic purposes, only a few studies have been reported on the value of the information extracted in brain cancer discrimination. The purpose of this study is threefold. First, to show that the diagnostic value of the information extracted from two different MRS scanners of 1.5T and 3T is significantly influenced in terms of brain gliomas discrimination. Second, to statistically evaluate the discriminative potential of publicly known metabolic ratio markers, obtained from these two types of scanners in classifying low-, intermediate-, and high-grade gliomas. Finally, to examine the diagnostic value of new metabolic ratios in the discrimination of complex glioma cases where the diagnosis is both challenging and critical. Our analysis has shown that although the information extracted from 3T MRS scanner is expected to provide better brain gliomas discrimination; some factors like the features selected, the pulse-sequence parameters, and the spectroscopic data acquisition methods can influence the discrimination efficiency. Finally, it is shown that apart from the bibliographical known, new metabolic ratio features such as N-acetyl aspartate/S, Choline/ S, Creatine/S, and myo-Inositol/S play significant role in gliomas grade discrimination.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 50 条
  • [1] Quantitative DCEMRI of the Breast at 1.5T and 3T
    Pineda, F.
    Medved, M.
    Fan, X.
    Ivancevic, M.
    Newstead, G.
    Abe, H.
    Sennett, C.
    Karczmar, G.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)
    Keihaninejad, Shiva
    Heckemann, Rolf A.
    Fagiolo, Gianlorenzo
    Symms, Mark R.
    Hajnal, Joseph V.
    Hammers, Alexander
    NEUROIMAGE, 2010, 50 (04) : 1427 - 1437
  • [3] Effects of Combining Field Strengths on Auditory Functional MRI Group Analysis: 1.5T and 3T
    Han, Kihwan
    Talavage, Thomas M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (06) : 1480 - 1488
  • [4] T1 at 1.5T and 3T compared with conventional T2*at 1.5T for cardiac siderosis
    Alam, Mohammed H.
    Auger, Dominique
    Smith, Gillian C.
    He, Taigang
    Vassiliou, Vassilis
    Baksi, A. John
    Wage, Rick
    Drivas, Peter
    Feng, Yanqiu
    Firmin, David N.
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [5] T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis
    Mohammed H. Alam
    Dominique Auger
    Gillian C. Smith
    Taigang He
    Vassilis Vassiliou
    A. John Baksi
    Rick Wage
    Peter Drivas
    Yanqiu Feng
    David N. Firmin
    Dudley J. Pennell
    Journal of Cardiovascular Magnetic Resonance, 17
  • [6] Quantification of pulsed saturation transfer at 1.5T and 3T
    Chan, Rachel W.
    Myrehaug, Sten
    Stanisz, Greg J.
    Sahgal, Arjun
    Lau, Angus Z.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (05) : 1684 - 1699
  • [7] 1.5T versus 3T MRI for targeting subthalamic nucleus for deep brain stimulation
    Cheng, Cheng-Hsin
    Huang, Hsing-Ming
    Lin, Hung-Lin
    Chiou, Shang-Ming
    BRITISH JOURNAL OF NEUROSURGERY, 2014, 28 (04) : 467 - 470
  • [8] 1.5t、3t电弧炉烟尘治理
    张顺喜
    杨洁
    工业安全与环保, 2009, 35 (06) : 9 - 11
  • [9] Carotid MRI Detection of Intraplaque Hemorrhage at 3T and 1.5T
    McNally, J. Scott
    Yoon, Hyo-Chun
    Kim, Seong-Eun
    Narra, Krishna K.
    McLaughlin, Michael S.
    Parker, Dennis L.
    Treiman, Gerald S.
    JOURNAL OF NEUROIMAGING, 2015, 25 (03) : 390 - 396
  • [10] COMPARING BETWEEN MR SPECTROSCOPY DONE AT 1.5T AND 3T
    Tang, Phua Hwee