Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

被引:4
|
作者
Kim, Seok-Gyu [1 ]
Chung, Chae-Heon [2 ]
Son, Mee-Kyoung [2 ]
机构
[1] Sungkyunkwan Univ, Coll Med, Samsung Med Ctr, Dept Prosthodont, Seoul, South Korea
[2] Chosun Univ, Coll Dent, Dept Prosthodont, Gwangju 501825, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2015年 / 7卷 / 03期
关键词
Implant-supported dental prosthesis; Torque; Dental cement; FINITE-ELEMENT-ANALYSIS; FIXED PARTIAL DENTURES; IN-VITRO; OSSEOINTEGRATED IMPLANTS; JOINT STABILITY; PASSIVE FIT; CROWNS; PROSTHODONTICS; TORQUE; RETRIEVABILITY;
D O I
10.4047/jap.2015.7.3.207
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [21] Cement- and screw-retained implant-supported prostheses: Up to 10 years of follow-up of a new design
    Preiskel, HW
    Tsolka, P
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (01) : 87 - 91
  • [22] Accuracy of a CAD/CAM-guided template for locating abutment screws for cement-retained implant-supported restorations
    Lee, Du-Hyeong
    Mai, Hang-Nga
    Li, Lin-Jie
    Lee, Keun Woo
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01): : 67 - 73
  • [23] Effect of different geometric changes in the dental implant abutment body on the amount of residual excess cement and retention in a cemented implant-supported prosthesis
    Negahdari, Ramin
    Bohlouli, Sepideh
    Yazdani, Javad
    Torab, Ali
    Dizaj, Solmaz Maleki
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (02) : 207 - 213
  • [24] Complications of screw- and cement-retained implant-supported full-arch restorations: a systematic review and meta-analysis
    Gaddale, Reetika
    Mishra, Sunil Kumar
    Chowdhary, Ramesh
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2020, 13 (01) : 11 - 40
  • [25] Effects of Screw- and Cement-Retained Implant-Supported Prostheses on Bone: A Nonlinear 3-D Finite Element Analysis
    Silva, Guilherme Carvalho
    de Andrade, Guilherme Martins
    Pinto Coelho, Rodrigo Carvalho
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Moreira, Allyson Nogueira
    IMPLANT DENTISTRY, 2015, 24 (04) : 464 - 471
  • [26] Porcelain Fracture Resistance of Screw-Retained, Cement-Retained, and Screw-Cement-Retained Implant-Supported Metal Ceramic Posterior Crowns
    Al-Omari, Wael M.
    Shadid, Rola
    Abu-Naba'a, Layla
    El Masoud, Bilal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (04): : 263 - 273
  • [27] Effectiveness of Sealing Gel on Vertical Misfit at the Implant-Abutment Interface and Preload Maintenance of Screw- Retained Implant-Supported Prostheses
    Seloto, Camila Berbel
    Strazzi-Sahyon, Henrico Badaoui
    dos Santos, Paulo Henrique
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (03) : 479 - 484
  • [28] Effect of Metal Extension of Crown in the Screw Access Channel of a Posterior Implant Abutment on the Retention of Cement Retained Prosthesis
    Biyani, Rashmi
    Ali, Mohsin
    Belles, Donald
    Powers, John M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (05) : 537 - 542
  • [29] Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
    Ebadian, Behnaz
    Fathi, Amirhossein
    Khodadad, Saba
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [30] Torque Maintenance of Screw-Retained Implant-Supported Anterior Fixed Dental Prosthesis with Different Abutment Angulations After Aging
    Al-Zordk, Walid
    Al-Dobaisi, Tawfik
    Ghazy, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : 723 - 729