Diagnostic Value of Electroencephalography with Ten Electrodes in Critically Ill Patients

被引:30
|
作者
Westover, M. Brandon [1 ]
Gururangan, Kapil [2 ]
Markert, Matthew S. [3 ]
Blond, Benjamin N. [4 ]
Lai, Saien [5 ]
Benard, Shawna [6 ]
Bickel, Stephan [7 ]
Hirsch, Lawrence J. [8 ]
Parvizi, Josef [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Neurol, Boston, MA 02114 USA
[2] Mt Sinai Hosp, New York, NY 10029 USA
[3] Stanford Univ, Med Ctr, Stanford, CA 94305 USA
[4] Stony Brook Univ Hosp, Stony Brook, NY USA
[5] Kaiser Permanente Med Ctr, Panorama City, CA USA
[6] Univ Southern Calif, Keck Hosp, Los Angeles, CA 90007 USA
[7] Hofstra Northwell, Zucker Sch Med, Long Isl City, NY USA
[8] Yale New Haven Med Ctr, 20 York St, New Haven, CT 06504 USA
关键词
Electroencephalography (EEG); Abbreviated EEG; Continuous EEG monitoring; Seizure prediction; Non-convulsive status epilepticus; Neuroemergencies; NONCONVULSIVE STATUS EPILEPTICUS; EEG MONTAGE; SEIZURES; PATTERNS; PROBABILITY; ASSOCIATION; ACCURACY; UTILITY; ARRAYS; SET;
D O I
10.1007/s12028-019-00911-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In critical care settings, electroencephalography (EEG) with reduced number of electrodes (reduced montage EEG, rm-EEG) might be a timely alternative to the conventional full montage EEG (fm-EEG). However, past studies have reported variable accuracies for detecting seizures using rm-EEG. We hypothesized that the past studies did not distinguish between differences in sensitivity from differences in classification of EEG patterns by different readers. The goal of the present study was to revisit the diagnostic value of rm-EEG when confounding issues are accounted for. Methods We retrospectively collected 212 adult EEGs recorded at Massachusetts General Hospital and reviewed by two epileptologists with access to clinical, trending, and video information. In Phase I of the study, we re-configured the first 4 h of the EEGs in lateral circumferential montage with ten electrodes and asked new readers to interpret the EEGs without access to any other ancillary information. We compared their rating to the reading of hospital clinicians with access to ancillary information. In Phase II, we measured the accuracy of the same raters reading representative samples of the discordant EEGs in full and reduced configurations presented randomly by comparing their performance to majority consensus as the gold standard. Results Of the 95 EEGs without seizures in the selected fm-EEG, readers of rm-EEG identified 92 cases (97%) as having no seizure activity. Of 117 EEGs with "seizures" identified in the selected fm-EEG, none of the cases was labeled as normal on rm-EEG. Readers of rm-EEG reported pathological activity in 100% of cases, but labeled them as seizures (N = 77), rhythmic or periodic patterns (N = 24), epileptiform spikes (N = 7), or burst suppression (N = 6). When the same raters read representative epochs of the discordant EEG cases (N = 43) in both fm-EEG and rm-EEG configurations, we found high concordance (95%) and intra-rater agreement (93%) between fm-EEG and rm-EEG diagnoses. Conclusions Reduced EEG with ten electrodes in circumferential configuration preserves key features of the traditional EEG system. Discrepancies between rm-EEG and fm-EEG as reported in some of the past studies can be in part due to methodological factors such as choice of gold standard diagnosis, asymmetric access to ancillary clinical information, and inter-rater variability rather than detection failure of rm-EEG as a result of electrode reduction per se.
引用
收藏
页码:479 / 490
页数:12
相关论文
共 50 条
  • [31] Continuous Electroencephalography in the Critically Ill: Clinical and Continuous Electroencephalography Markers for Targeted Monitoring
    Newey, Christopher R.
    Kinzy, Tyler G.
    Punia, Vineet
    Hantus, Stephen
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2018, 35 (04) : 325 - 331
  • [32] DIAGNOSTIC VALUE OF DIAZEPAM IN ELECTROENCEPHALOGRAPHY
    LAGUNA, JF
    KOREIN, J
    ARCHIVES OF NEUROLOGY, 1972, 26 (03) : 265 - &
  • [33] PROGNOSTIC VALUE OF THROMBOELASTOGRAPHY IN CRITICALLY ILL PATIENTS WITH CIRRHOSIS
    Wallace, Franklyn
    Rattan, Puru
    Lennon, Ryan
    GalloDeMoraes, Alice
    Simonetto, Douglas A.
    HEPATOLOGY, 2022, 76 : S921 - S922
  • [34] THE PROGNOSTIC VALUE OF SERUM OSMOLALITY IN CRITICALLY ILL PATIENTS
    MAJDANDZIC, J
    LANGE, D
    SCHUSTER, HP
    WEILEMANN, LS
    REY, C
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 243 - 243
  • [35] PROGNOSTIC VALUE OF DELTA OF PREALBUMIN IN CRITICALLY ILL PATIENTS
    Sandoval Almengor, J. C.
    Lopez Perez, H. R.
    Franco Granillo, J.
    Aguirre Sanchez, J.
    Villalobos Silva, J. A.
    Sanchez Castrillo, C. G.
    INTENSIVE CARE MEDICINE, 2009, 35 : 149 - 149
  • [36] PROGNOSTIC VALUE OF BLOOD LACTATE IN CRITICALLY ILL PATIENTS
    SCHUSTER, HP
    RESUSCITATION, 1984, 11 (3-4) : 141 - 146
  • [37] Continuous Electroencephalography Monitoring in Critically Ill Infants and Children
    Griffith, Jennifer L.
    Tomko, Stuart T.
    Guerriero, Rejean M.
    PEDIATRIC NEUROLOGY, 2020, 108 : 40 - 46
  • [38] Value of prealbumin in assessment of nutrition for critically ill patients
    Agilli, Mehmet
    Ekinci, Safak
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2015, 45 (04) : 991 - 991
  • [39] THE PREDICTIVE VALUE OF PROCALCITONIN IN CRITICALLY ILL PEDIATRIC PATIENTS
    Valentine, Beryl
    Harris, Courtney
    Shanmu, Swapna
    Havalad, Vinod
    CRITICAL CARE MEDICINE, 2020, 48
  • [40] THE PROGNOSTIC VALUE OF HEMODYNAMICS IN CRITICALLY ILL CARDIAC PATIENTS
    LYNCH, JJ
    LEHMAN, D
    LESAC, C
    SIEGEL, R
    KEELAN, MH
    TRESCH, DD
    BROOKS, HL
    CLINICAL RESEARCH, 1983, 31 (04): : A707 - A707