Risk of stroke early after implantation of a left ventricular assist device

被引:10
|
作者
Samura, Takaaki [1 ]
Yoshioka, Daisuke [1 ]
Toda, Koichi [1 ]
Sakaniwa, Ryoto [2 ]
Shimizu, Mikito [3 ]
Miyagawa, Shigeru [1 ]
Yoshikawa, Yasushi [1 ]
Hata, Hiroki [1 ]
Saito, Shunsuke [1 ]
Sakata, Yasushi [4 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Yamadaoka 2-2, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Publ Hlth, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Neurol, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Cardiol, Osaka, Japan
来源
关键词
left ventricular assist device; low cardiac output; pump thrombosis; stroke; HEART MATE II; INTERAGENCY REGISTRY; HEMORRHAGIC STROKE; PUMP THROMBOSIS; MORTALITY; HEMOLYSIS;
D O I
10.1016/j.jtcvs.2018.06.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Stroke is one of the major adverse events after left ventricular assist device implantation. Risk of stroke is the highest immediately after left ventricular assist device implantation and then increases again in chronic periods. There is no study that has analyzed risk factors for stroke in acute phase. We investigated the risk factors for stroke in the acute phase after left ventricular assist device implantation in the present study. Methods: Between October 2005 and December 2016, 158 consecutive patients (mean age, 43 +/- 14 years; 34% were women) underwent continuous-flow left ventricular assist device (50 HeartMate II [Abbott Medical, Abbott Park, III], 38 DuraHeart [Terumo Heart, Ann Arbor, Mich], 33 Jarvik2000 [Jarvik Heart, New York, NY], 23 EVAHEART [Sun Medical, Moriyama City, Japan], 14 HeartWare [Framingham, Mass]) implantation in our institution. We analyzed the risk factors for a symptomatic stroke within 90 days after left ventricular assist device implantation. Results: Stroke occurred in 28 patients in the acute phase after left ventricular assist device implantation. Multivariate analysis revealed that low cardiac output (odds ratio, 0.25; 0.07-0.92; P = .024) during postoperative 12 to 24 hours was the only independent risk factor for stroke in the acute phase. Patients with stroke in the acute phase had higher serum lactate dehydrogenase levels at any point until postoperative 14 days. Patients with the HeartMate II device particularly showed a statistically significant negative relationship between cardiac output during postoperative 12 to 24 hours and serum lactate dehydrogenase levels at postoperative 14 days (r = -0.313, P = .03). Conclusions: Our study demonstrated that patients with perioperative lower cardiac output and higher lactate dehydrogenase level developed stroke in the acute phase after left ventricular assist device implantation. These results suggested that maintenance of sufficient left ventricular assist device flow is important in prevention of stroke, which may be related to subclinical pump thrombosis.
引用
收藏
页码:259 / +
页数:10
相关论文
共 50 条
  • [41] Stroke Risk Quantification For Patients With A Left Ventricular Assist Device
    Sahni, Akshita
    Mcintyre, Erin E.
    Pal, Jay D.
    Mukherjee, Debanjan
    STROKE, 2023, 54
  • [42] Smoking and the Risk of Stroke in Patients with a Left Ventricular Assist device
    Sherazi, Saadia
    Goldenberg, Ilan
    McNitt, Scott
    Kutyifa, Valentina
    Gosev, Igor
    Wood, Katherine
    Chen, Leway
    Polonsky, Bronislava
    Vidula, Himabindu
    Alexis, Jeffrey D.
    ASAIO JOURNAL, 2021, 67 (11) : 1217 - 1221
  • [43] Right ventricular failure after left ventricular assist device implantation:: The need for an implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2005, 29 (05) : 369 - 377
  • [44] Outcomes after stroke complicating left ventricular assist device
    Willey, Joshua Z.
    Gavalas, Michael. V.
    Trinh, Pauline N.
    Yuzefpolskaya, Melana
    Garan, A. Reshad
    Levin, Allison P.
    Takeda, Koji
    Takayama, Hiroo
    Fried, Justin
    Naka, Yoshifumi
    Topkara, Veli K.
    Colombo, Paolo C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (08): : 1003 - 1009
  • [45] Prediction of right ventricular dysfunction after left ventricular assist device implantation
    Nakatani, S
    Thomas, JD
    Savage, RM
    Vargo, RL
    Smedira, NG
    McCarthy, PM
    CIRCULATION, 1996, 94 (09) : 216 - 221
  • [46] Predictors of right ventricular failure after left ventricular assist device implantation
    Koprivanac, Marijan
    Kelava, Marta
    Siric, Franjo
    Cruz, Vincent B.
    Moazami, Nader
    Mihaljevic, Tomislav
    CROATIAN MEDICAL JOURNAL, 2014, 55 (06) : 587 - 595
  • [47] Left Ventricular Assist Device Implantation After Intracardiac Parachute Device Removal
    Abu Saleh, Walid K.
    Al Jabbari, Odeaa
    Bruckner, Brian A.
    Suarez, Erik E.
    Estep, Jerry D.
    Loebe, Matthias
    ANNALS OF THORACIC SURGERY, 2015, 100 (02): : 720 - 722
  • [48] DESCRIPTIVE ANALYSIS OF VENTRICULAR TACHYCARDIA AFTER LEFT VENTRICULAR ASSIST DEVICE IMPLANTATION
    Butler, Simona
    Adie, Sarah
    Clark, Angela
    CRITICAL CARE MEDICINE, 2019, 47
  • [49] Ventricular Fibrillation 7 Years After Left Ventricular Assist Device Implantation
    Eyituoyo, Harry O.
    Aben, Rieta N.
    Arinze, Nkechi C.
    Dat Phat Vu
    James, Erskine A.
    AMERICAN JOURNAL OF CASE REPORTS, 2020, 21 : 1 - 5
  • [50] Incidence and Risk Factors for Early Stroke Following Durable Left Ventricular Assist Device (LVAD) Implantation: An STS Intermacs Analysis
    Molina, E.
    Goldstein, D.
    Cantor, R.
    Kanwar, M.
    Meyer, D.
    Jorde, U.
    Saeed, O.
    Wood, K.
    Rudraraju, R.
    Lewis, S.
    Kirklin, J.
    Pagani, F.
    Kilic, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S59 - S60