Experimental and Numerical Simulation of a Radiant Floor System: The Impact of Different Screed Mortars and Floor Finishings

被引:10
|
作者
Almeida, Ricardo M. S. F. [1 ,2 ]
Vicente, Romeu da Silva [3 ]
Ventura-Gouveia, Antonio [1 ,4 ]
Figueiredo, Antonio [3 ]
Rebelo, Filipe [3 ]
Roque, Eduardo [3 ]
Ferreira, Victor M. [3 ]
机构
[1] Polytech Inst Viseu, Dept Civil Engn, Campus Politecn Repeses, P-3504510 Viseu, Portugal
[2] Univ Porto, Inst R&D Sctruct & Construct LFC CONSTRUCT LFC, Fac Engn FEUP, Rua Dr Roberto Frias S-N, P-4200465 Porto, Portugal
[3] Univ Aveiro, Res Ctr Risks & Sustainabil Construct RISCO, Dept Civil Engn, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[4] Univ Minho, Inst Sustainabil & Innovat Struct Engn ISISE, Dept Civil Engn, Campus Azurem, P-4800058 Guimaraes, Portugal
关键词
radiant floor; heat transfer; screed mortar; thermal analysis; finite element method; floor finishing; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIALS; COUPLED HEAT-PUMP; COOLING SYSTEMS; PERFORMANCE; PCM; BUILDINGS; OPTIMIZATION; EFFICIENCY; DESIGN;
D O I
10.3390/ma15031015
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The radiant floor system market is growing rapidly because Europe is moving toward a low-carbon economy and increased awareness about environmental sustainability and energy efficiency, stimulated by the ambitious EU Energy Efficient Directive and nZEB challenge. The high growth rate of the market share is due to the involvement of homeowners in the specifications of their living commodities, so they are thus willing to invest more at the initial stage to obtain long-term benefits and lower energy exploration costs. We performed an experimental campaign over three slabs with a hydronic radiant floor system of equal dimensions, shape, and pipe pitch with different screed mortar formulations to assess their performance throughout a heating/cooling cycle. The temperature at different heights within the interior of the screed mortars and at the surface were monitored. The results revealed that an improved screed mortar has a relevant impact on the efficiency of the system. Moreover, a three-dimensional transient heat transfer model was validated using the experimental data. The model was used to evaluate the impact of different finishing materials, namely wood, cork, ceramic, and linoleum, on the floor surface temperatures. The results showed differences of 15% in the surface temperature when using different floor finishing solutions.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental study on the dynamic thermal response of a radiant floor system in an office building
    Ren, Jing
    Su, Meng
    Zhao, Xintian
    Liu, Jiying
    Song, Shoujie
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [32] Numerical study on impact of non-heating surface temperature on the heat output of radiant floor heating system
    Zheng, Xuejing
    Han, Yong
    Zhang, Huan
    Zheng, Wandong
    Kong, Dehui
    ENERGY AND BUILDINGS, 2017, 155 : 198 - 206
  • [33] Experimental Study on Ceiling Radiant Cooling Panel System with Personal Floor Diffuser
    Ito, Sei
    Kawashima, Minoru
    Arai, Yoshito
    Suzuki, Michiya
    Murakami, Koji
    Nobe, Tatsuo
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 330 - 337
  • [34] Experimental study of low-temperature electrical radiant floor heating system
    Kong, Xiangqiang
    Li, Ying
    Hu, Songtao
    Journal of Southeast University (English Edition), 2010, 26 (02) : 287 - 291
  • [35] Experimental Study of a Low-temperature Electrical Radiant Floor Heating System
    Kong, Xiangqiang
    Li, Ying
    Wang, Ruzhu
    Hu, Songtao
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1593 - 1600
  • [36] Experimental Research on the Parameter Optimization of a Radiant Floor Heating System with Reflective Modules
    Yu, Jin
    Feng, Jiangfa
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3114 - 3119
  • [37] Experimental test and analysis of low-temperature floor radiant heating system
    Liu, GD
    Yu, HL
    Li, YW
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1153 - 1160
  • [38] AN EXPERIMENTAL STUDY ON THE PERFORMANCE OF RADIANT FLOOR COOLING MODULES
    Chien, K. C.
    Chuah, Y. K.
    Chang, W. T.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2013, 21 (02)
  • [39] Simulation Analysis of Heat Transfer on Low Temperature Hot-water Radiant Floor Heating and Electrical Radiant Floor Heating
    Qi, Hanbing
    He, Fuyun
    Wang, Qiushi
    Li, Dong
    Lin, Lin
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4234 - +
  • [40] NUMERICAL CALCULATION OF THE FLOOR-RADIANT HEATING TEMPERATURE FIELD
    Ran, Chunyu
    Wang, Chunqing
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2287 - 2292