Dynamic simulation of existing buildings: considerations on the model calibration

被引:1
|
作者
Angelotti, Adriana [1 ]
Ballabio, Micol [1 ]
Mazzarella, Livio [1 ]
Cornaro, Cristina [2 ]
Parente, Gianmarco [2 ]
Frasca, Francesca [3 ]
Prada, Alessandro [4 ]
Baggio, Paolo [4 ]
Ballarini, Ilaria [5 ]
De Luca, Giovanna [2 ]
Corrado, Vincenzo [5 ]
机构
[1] Politecn Milan, Dipartimento Energia, Milan, Italy
[2] Univ Roma Tor Vergata, Dipartimento Ingn Impresa, Rome, Italy
[3] Univ Roma La Sapienza, Dipartimento Fis, Rome, Italy
[4] Univ Trento, Dipartimento Ingn Civile Ambientale & Meccan, Trento, Italy
[5] Politecn Torino, Dipartimento Energia, Turin, Italy
来源
PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA | 2020年
关键词
OCCUPANT BEHAVIOR; ENERGY SIMULATION; VALIDATION;
D O I
10.26868/25222708.2019.210439
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dynamic energy simulation is increasingly used to design retrofit interventions in existing buildings. Energy savings are correctly predicted if the simulation model is carefully calibrated against measured data. In this study the same building storey is simulated by four different research groups with different dynamic simulation tools (EnergyPlus, TRNSYS, IDA ICE). The building envelope is simulated in free floating and a parametric analysis to envelope properties and users' behaviour is carried out. A set of basic information and measurements on the building is made available to three groups, while detailed information and measured data are provided to the fourth one. From the comparison among calibrated models it is concluded that, for a good calibration of a well-insulated building model, the absence of data regarding users' behaviour can be more critical than detailed measurements on the envelope properties.
引用
收藏
页码:4165 / 4172
页数:8
相关论文
共 50 条
  • [31] Calibration and simulation of Heston model
    Mrazek, Milan
    Pospisil, Jan
    OPEN MATHEMATICS, 2017, 15 : 679 - 704
  • [32] A protocol for dynamic model calibration
    Villaverde, Alejandro F.
    Pathirana, Dilan
    Frohlich, Fabian
    Hasenauer, Jan
    Banga, Julio R.
    BRIEFINGS IN BIOINFORMATICS, 2022, 23 (01)
  • [33] Seismic collapse simulation of existing masonry buildings with different retrofitting techniques
    Ge Dongdong
    Du Chunbo
    Miao Qisong
    Chen Xi
    Earthquake Engineering and Engineering Vibration, 2021, 20 (01) : 127 - 139
  • [34] Seismic collapse simulation of existing masonry buildings with different retrofitting techniques
    Dongdong Ge
    Chunbo Du
    Qisong Miao
    Xi Chen
    Earthquake Engineering and Engineering Vibration, 2021, 20 : 127 - 139
  • [35] Seismic collapse simulation of existing masonry buildings with different retrofitting techniques
    Ge Dongdong
    Du Chunbo
    Miao Qisong
    Chen Xi
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2021, 20 (01) : 127 - 139
  • [36] Dynamic properties of existing RC buildings using measurements of ambient vibrations
    Navarro, M.
    Oliveira, C. S.
    Structural Dynamics - EURODYN 2005, Vols 1-3, 2005, : 1847 - 1852
  • [37] The retrofit of existing buildings through the exploitation of the green roofs - a simulation study
    Gagliano, A.
    Detommaso, M.
    Nocera, F.
    Patania, F.
    Aneli, S.
    6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 : 52 - 61
  • [38] A dynamic simulation study on the sustainability of prefabricated buildings
    Liu, Sha
    Li, Zhongfu
    Teng, Yue
    Dai, Liren
    SUSTAINABLE CITIES AND SOCIETY, 2022, 77
  • [39] OPC model calibration considerations for data variance
    Bahnas, Mohamed
    Al-Imam, Mohamed
    OPTICAL MICROLITHOGRAPHY XXI, PTS 1-3, 2008, 6924
  • [40] Dynamic simulation of cracked buildings for damage detection
    Alonso-Rivers A.
    Salgado-Estrada R.
    Salgado-Estrada, Rolando (rosalgado@uv.mx), 1600, Tech Science Press (14): : 187 - 204