Development of real-time loop-mediated isothermal amplification (RealAmp) method for sensitive and rapid detection of pathogenic and nonpathogenic Leptospira

被引:10
|
作者
Monica, N. I. [1 ]
Rathinasabapathi, P. [1 ]
Ramya, M. [1 ]
机构
[1] SRM Inst Sci & Technol, Sch Bioengn, Dept Genet Engn, Kattankulathur 603203, Tamil Nadu, India
关键词
LAMP; Leptospira; lipL21; lipL32; RealAmp; IGM ELISA; DIAGNOSIS; IDENTIFICATION; LAMP; LIPOPROTEIN; SPP;
D O I
10.1111/lam.13108
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Leptospirosis is a zoonotic disease that is spread through water contaminated with the spirochete Leptospira. In our study, RealAmp (real-time loop-mediated isothermal amplification) was developed to distinguish between pathogenic and nonpathogenic Leptospira spp. Melt curve analysis of RealAmp showed two distinct melt curves for pathogenic and nonpathogenic Leptospira spp with a Tm value of 90 +/- 2 and 88 +/- 2 degrees C. The sensitivity of the developed method is as low as 1 pg mu l(-1) of Leptospira DNA. Specificity was achieved to distinguish Leptospira species using the marker genes (lipL32 and lipL21). Different environmental water samples collected from cattle shelter, pisciculture and stagnant water were tested using this RealAmp method. Pisciculture water samples were found to be highly contaminated with both pathogenic and nonpathogenic Leptospira spp (50%), followed by cattle shelter and stagnant water samples (15%). Significance and Impact of the Study The occurrence of pathogenic Leptospira in the environment is a threat to humans and animals. Molecular-based differentiation of the pathogenic and nonpathogenic Leptospria is essential for environmental monitoring; however, the currently available detection methods fail to distinguish between these species. We report here a real-time loop-mediated isothermal amplification-based method that differentiates between the pathogenic and nonpathogenic Leptospira based on the melt curve analysis of the marker genes lipL32 and lipL21. The method was successfully tested with a variety of environmental water samples to study the prevalence of Leptospira in the environment.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 50 条
  • [41] Development of a novel primer combination to detect pathogenic Leptospira by loop-mediated isothermal amplification
    Suwancharoen, D.
    Kulchim, C.
    Chirathaworn, C.
    Yoshida, S.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 91 (01) : 171 - 173
  • [42] Development of the loop-mediated isothermal amplification method for rapid detection of cytomegalovirus DNA
    Suzuki, R
    Yoshikawa, T
    Ihira, M
    Enomoto, Y
    Inagaki, S
    Matsumoto, K
    Kato, K
    Kudo, K
    Kojima, S
    Asano, Y
    JOURNAL OF VIROLOGICAL METHODS, 2006, 132 (1-2) : 216 - 221
  • [43] Development of a loop-mediated isothermal amplification method for the rapid detection of Pythium ultimum
    Danyu Shen
    Qingling Li
    Jia Yu
    Yuanyuan Zhao
    Ye Zhu
    Heng Xu
    Daolong Dou
    Australasian Plant Pathology, 2017, 46 : 571 - 576
  • [44] Probe-specific loop-mediated isothermal amplification magnetogenosensor assay for rapid and specific detection of pathogenic Leptospira
    Najian, A. B. Nurul
    Foo, Phiaw Chong
    Ismail, Nabilah
    Kim-Fatt, Low
    Yean, Chan Yean
    MOLECULAR AND CELLULAR PROBES, 2019, 44 : 63 - 68
  • [45] Development of a loop-mediated isothermal amplification method for rapid detection of reticuloendotheliosis virus
    Deng, Xiaoyun
    Qi, Xiaole
    Gao, Yulong
    Wang, Yongqiang
    Qin, Liting
    Gao, Honglei
    Gao, Li
    Wang, Xiaomei
    JOURNAL OF VIROLOGICAL METHODS, 2010, 168 (1-2) : 82 - 86
  • [46] Development of a real-time loop-mediated isothermal amplification method for the detection of severe fever with thrombocytopenia syndrome virus
    Lee, Jae Woong
    Won, Yu-Jung
    Kang, Lae Hyung
    Lee, Sung-Geun
    Park, Seung-Won
    Paik, Soon-Young
    JOURNAL OF MICROBIOLOGY, 2020, 58 (08) : 711 - 715
  • [47] Development of a real-time loop-mediated isothermal amplification method for the detection of severe fever with thrombocytopenia syndrome virus
    Jae Woong Lee
    Yu-Jung Won
    Lae Hyung Kang
    Sung-Geun Lee
    Seung-Won Park
    Soon-Young Paik
    Journal of Microbiology, 2020, 58 : 711 - 715
  • [48] Development of a loop-mediated isothermal amplification method for rapid detection of pigeon circovirus
    Shinn Shyong Tsai
    Yeng Ling Chang
    Yen Li Huang
    Hung Jen Liu
    Guan Ming Ke
    Chwei Jang Chiou
    Yao Ching Hsieh
    Tsung Chou Chang
    Li Ting Cheng
    Kuo Pin Chuang
    Archives of Virology, 2014, 159 : 921 - 926
  • [49] Development of a loop-mediated isothermal amplification method for the rapid detection of Pythium ultimum
    Shen, Danyu
    Li, Qingling
    Yu, Jia
    Zhao, Yuanyuan
    Zhu, Ye
    Xu, Heng
    Dou, Daolong
    AUSTRALASIAN PLANT PATHOLOGY, 2017, 46 (06) : 571 - 576
  • [50] Development of probe-based real-time loop-mediated isothermal amplification for detection of Brucella
    Bhat, I. A.
    Mashooq, M.
    Kumar, D.
    Varshney, R.
    Rathore, R.
    JOURNAL OF APPLIED MICROBIOLOGY, 2019, 126 (05) : 1332 - 1339