Full-field OCT: applications in ophthalmology

被引:0
|
作者
Grieve, K [1 ]
Dubois, A [1 ]
Paques, M [1 ]
Le Gargasson, JF [1 ]
Boccara, AC [1 ]
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, CNRS, UPR A0005, Lab Opt Phys, F-75231 Paris, France
来源
Ophthalmic Technologies XV | 2005年 / 5688卷
关键词
interference microscopy; optical coherence tomography; medical and biomedical imaging;
D O I
10.1117/12.588649
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We present images of ocular tissues obtained using ultrahigh resolution full-field OCT. The experimental setup is based on the Linnik interferometer, illuminated by a tungsten halogen lamp. En face tomographic images are obtained in real-time without scanning by computing the difference of two phase-opposed interferometric images recorded by a high-resolution CCD camera. A spatial resolution of 0.7 mu m 0.9 mu m (axial x transverse) is achieved thanks to the short source coherence length and the use of high numerical aperture microscope objectives. A detection sensitivity of 90 dB is obtained by means of image averaging and pixel binning. Whole unfixed eyes and unstained tissue samples (cornea, lens. retina, choroid and sclera) of ex vivo rat, mouse. rabbit and porcine ocular tissues were examined. The unprecedented resolution of our instrument allows cellular-level resolution in the cornea and retina, and visualization of individual fibers in the lens. Transcorneal lens imaging was possible in all animals. and in albino animals, transscleral retinal imaging was achieved. We also introduce our rapid acquisition full-field optical coherence tomography system designed to accommodate in vivo ophthalmologic imaging. The variations on the original system technology include the introduction of a xenon arc lamp as source, and rapid image acquisition performed by a high-speed CMOS camera. reducing acquisition time to 5 ins per frame.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [41] Ultra highspeed in-vivo Fourier domain full-field OCT of the human retina
    Bonin, Tim
    Hagen-Eggert, Martin
    Franke, Gesa
    Koch, Peter
    Huettmann, Gereon
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [42] Simultaneous directional full-field OCT using path-length and carrier multiplexing
    Valente, Denise
    Vienola, Kari V.
    Zawadzki, Robert J.
    Jonnal, Ravi S.
    OPTICS EXPRESS, 2021, 29 (20) : 32179 - 32195
  • [43] High resolution imaging of intracellular dynamics in explanted retinas with dynamic full-field OCT
    Thouvenin, Olivier
    Boccara, A. Claude
    Paques, Michel
    Sahel, Jose-Alain
    Fink, Mathias
    Grieve, Katharine F.
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [44] Non-contact millimeter-field imaging of in vivo corneal cells by full-field OCT
    Mazlin, V.
    Xiao, P.
    Grieve, K.
    Sahel, J. A.
    Fink, M.
    Boccara, C.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 81 - 82
  • [45] Full-field digital mammography
    Bick, U
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [46] An improved full-field compensator
    Hariharan, P
    Ciddor, PE
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (08) : 936 - 937
  • [47] A full-field optical crazimeter
    Kumar, Raj
    Varshney, Tushar
    Yadav, Tarun
    Dwivedi, Gaurav
    Barve, S. K.
    Singh, Omendra
    JOURNAL OF OPTICS, 2021, 23 (12)
  • [48] Coherence gate shaping for wide field high-resolution in vivo retinal imaging with full-field OCT
    Mece, Pedro
    Groux, Kassandra
    Scholler, Jules
    Thouvenin, Olivier
    Fink, Mathias
    Grieve, Kate
    Boccara, Claude
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (09) : 4928 - 4941
  • [49] Improved full-field compensator
    CSIRO Natl Measurement Lab, Lindfield
    Meas Sci Technol, 8 (936-937):
  • [50] Paraxial full-field cloaking
    Choi, Joseph S.
    Howell, John C.
    OPTICS EXPRESS, 2015, 23 (12): : 15857 - 15862