Comparison of HIV-1 RNA Measurements Obtained by Using Plasma and Dried Blood Spots in the Automated Abbott Real-Time Viral Load Assay

被引:35
|
作者
Arredondo, Miguel [1 ]
Garrido, Carolina [1 ]
Parkin, Neil [2 ,3 ]
Zahonero, Natalia [1 ]
Bertagnolio, Silvia [2 ]
Soriano, Vincent [1 ]
de Mendoza, Carmen [1 ]
机构
[1] Hosp Carlos III, Dept Infect Dis, Madrid, Spain
[2] World Hlth Org, HIV Dept, Geneva, Switzerland
[3] Data First Consulting Inc, Menlo Pk, CA USA
关键词
DRUG-RESISTANCE SURVEILLANCE; DIFFERENT STORAGE-CONDITIONS; QUANTITATIVE ASSAYS; WHOLE-BLOOD; SPECIMENS; QUANTIFICATION; DIAGNOSIS; CAMEROON;
D O I
10.1128/JCM.00418-11
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Dried blood spots (DBS) may be a promising alternative specimen type to plasma for measuring the viral load (VL) in HIV-infected individuals in resource-limited settings. However, characterization of assay performance using DBS is incomplete. In this prospective study, the VL was measured in parallel using plasma and DBS specimens collected at the same time from 157 HIV-1-infected individuals. DBS were prepared by dispensing 50 mu l of blood onto filter paper cards and were stored desiccated at -20 degrees C. Nucleic acid extraction from plasma and DBS was performed automatically using the Abbott m2000sp instrument, and the VL was measured using the RealTime HIV-1 VL assay, which has a lower limit of detection of 40 HIV RNA copies/ml. The correlation between plasma and DBS results was good (R = 0.91; P < 0.001). The mean difference in the VL (DBS minus plasma) was 0.35 log copies (standard deviation [SD], 0.47 log copies). A total of 40 (26%) paired specimens had a difference of >0.5 log copy, and in 12 (7.8%) it was >1 log copy. the VL from DBS was measurable in 95.7% of specimens with a plasma VL of >2.74 log copies (550 HIV RNA copies/ml). In summary, the VL can reliably be measured using DBS with the Abbott RealTime HIV-1 assay. The estimated lower limit of detection of this automated methodology on DBS is 550 copies/ml, a threshold that may be acceptable for periodic VL monitoring in patients on antiretroviral therapy in resource-limited settings, where early detection of virologic treatment failure is often problematic.
引用
收藏
页码:569 / 572
页数:4
相关论文
共 50 条
  • [31] Dried blood spots provide accurate enumeration of HIV-1 viral load in east Africa
    Barnabas, R.
    Coombs, R.
    Chang, M.
    Schaafsma, T.
    Asiimwe, S.
    Thomas, K.
    Baeten, J.
    Celum, C.
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2016, 19
  • [32] Design and Development of a Quantitative TaqMan Real-Time PCR Assay for Evaluation of HIV-1 (group M) Viral Load in Plasma Using Armored RNA Standard
    Gholami, Mohammad
    Baesi, Kazem
    Ravanshad, Mehrdad
    Samiee, Siamak M.
    Rouzbahani, Negin H.
    Mohraz, Minoo
    CLINICAL LABORATORY, 2018, 64 (06) : 955 - 963
  • [33] Performance of a novel viral load assay for plasma HIV-1 RNA quantification compared with Roche real time PCR in China
    Li, Jiaojiao
    He, Ruiying
    Lin, Yaqing
    Guo, Pengle
    Liu, Cong
    Deng, Xizi
    Li, Linghua
    Lan, Yun
    JOURNAL OF VIROLOGICAL METHODS, 2025, 333
  • [34] Measurement of HIV-1 Viral Load for Drug Resistance Surveillance using Dried Blood Spots: Literature Review and Modeling of Contribution of DNA and RNA
    Parkin, Neil T.
    AIDS REVIEWS, 2014, 16 (03) : 160 - 171
  • [35] Low Level Virus Load Detection Confidence of Abbott Real-Time HIV-1, Roche TaqMan HIV-1 and Versant HIV-1 RNA (bDNA) Technologies for Quantification of Plasma HIV-1 RNA in HIV-1 Infected Individuals
    Toth, M.
    Davila, L.
    Valiathan, R.
    Deeb, K.
    Young, T. P.
    Cloherty, G.
    Fischl, M.
    Asthana, D.
    Bolivar, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06): : 735 - 736
  • [36] HIV-1 viral load measurement and PCR for drug resistance genotyping using dried blood spots and dried plasma spots collected from antiretroviral therapy-experienced patients
    Zhang, J.
    Kang, D.
    Sun, X.
    Lin, B.
    Fu, J.
    Bi, Z.
    Nkengasong, J.
    Yang, C.
    ANTIVIRAL THERAPY, 2010, 15 : A146 - A146
  • [37] Evaluation Of Abbott RealTime HIV 1 Qualitative Assay In Detection Of HIV 1 Nucleic Acids From Dried Blood Spots And Plasma
    Huang, S.
    Mak, W.
    Erickson, B.
    Salituro, J.
    Abravaya, K.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2010, 12 (06): : 915 - 915
  • [38] HIV-1 Load Comparison Using Four Commercial Real-Time Assays
    Bourlet, Thomas
    Signori-Schmuck, Anne
    Roche, Laurent
    Icard, Vinca
    Saoudin, Henia
    Trabaud, Mary-Anne
    Tardy, Jean-Claude
    Morand, Patrice
    Pozzetto, Bruno
    Ecochard, Rene
    Andre, Patrice
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (01) : 292 - 297
  • [39] Correlation between GeneXpert, a novel Human Immunodeficiency Virus type 1 (HIV-1) assay for viral load measurement assay with the Abbott m2000 real-time assay
    Masuko, S.
    Chigiga, J.
    Hodson, J.
    Dedicoat, K.
    Killick, P.
    Osman, H.
    Manavi, K.
    HIV MEDICINE, 2016, 17 : 28 - 29
  • [40] PERFORMANCE EVALUATION OF THE APTIMA HIV-1 QUANT DX ASSAY FOR DETECTION OF HIV-1 IN PLASMA AND DRIED BLOOD SPOTS (DBS)
    Carrera, A.
    Sherring, J.
    McNally, L.
    Lowe, P.
    Cunningham, P. H.
    SEXUALLY TRANSMITTED INFECTIONS, 2015, 91 : A211 - A211