Assessment of exhaled nitric oxide by a new hand-held device

被引:38
|
作者
Antus, Balazs [1 ]
Horvath, Ildiko [2 ]
Barta, Imre [1 ]
机构
[1] Natl Koranyi Inst TB & Pulmonol, Dept Pathophysiol, H-1529 Budapest, Hungary
[2] Semmelweis Univ, Dept Pulmonol, H-1125 Budapest, Hungary
关键词
Exhaled nitric oxide; Logan; NIOX MINO; NObreath; Reproducibility; ASTHMA; ANALYZER;
D O I
10.1016/j.rmed.2010.06.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fractional exhaled nitric oxide (FENO) has been implicated as a pulmonary biomarker. The aim of this study was to compare the performance of a new hand-held device to a standard chemiluminescence analyzer and to another portable device. Methods: FENO levels measured by NObreath (Bedfont) were compared to those of (1) a chemiluminescence detector (Logan, Logan Research) and (2) the electrochemical portable NIOX MINO (Aerocrine) in 18 healthy volunteers on three consecutive occasions: in the morning, 1 h and 24 h later. Results: Comparing FENO levels obtained by NObreath to those by Logan values were similar and a very close linear relationship was found between the two devices (r = 0.923, p < 0.001). The mean inter-device difference in FENO level was -3.45 ppb and the limits of agreement (Bland-Altman test) were -10.98 and 4.08 ppb. In the second series FENO levels obtained by NObreath were found to be slightly higher compared to those of NIOX MINO, but still showed a close correlation (r = 0.681, p < 0.001). The mean inter-device difference in FENO level was 4.36 ppb and the limits of agreement were -7.38 and 16.1 ppb. Analyzing the repeated FENO measurements, the mean coefficient of variation using NObreath tended to be lower than that of NIOX MINO (16.9 vs. 24.7%, p = 0.059), while it was similar as the value obtained with Logan (11.8 vs. 9.0%, p = 0.342). Conclusions: FENO values measured with NObreath are reproducible and in good agreement with those obtained by NIOX MINO and Logan indicating that NObreath is suitable for use in clinical practice. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1377 / 1380
页数:4
相关论文
共 50 条
  • [21] Hand-held device tests for drugs
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 31 : X - X
  • [22] Hand-held device for smoke extraction
    King, P. M.
    Ferguson, D. J.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2010, 92 (05) : 441 - 441
  • [23] Hand-held device for smoke extraction
    Ali-Khan, Ahmed S.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (04) : 333 - 333
  • [24] Hand-held device detects viruses
    Ymeti, Aurel
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) : III - III
  • [25] A New Hand-Held Force-Amplifying Device for Micromanipulation
    Payne, Christopher J.
    Latt, Win Tun
    Yang, Guang-Zhong
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 1583 - 1588
  • [26] The coriotome -: A new hand-held device for trimming of skin grafts
    Kasten, R
    Voigtländer, V
    DERMATOLOGIC SURGERY, 2004, 30 (05) : 787 - 791
  • [27] NEW MECHANIZED AND HAND-HELD SCALING DEVICE FOR UNDERGROUND MINING
    PLANETA, S
    CIM BULLETIN, 1995, 88 (987): : 38 - 42
  • [28] Hand-held fractional exhaled nitric oxide measurements as a non-invasive indicator of systemic inflammation in Crohn's disease
    Quenon, L.
    Hindryckx, P.
    De Vos, M.
    De Looze, D.
    Joos, G.
    Brusselle, G.
    Peeters, H.
    JOURNAL OF CROHNS & COLITIS, 2013, 7 (08): : 644 - 648
  • [29] Comparison of Exhalation Time Methods (6 sec vs. 10 sec) of a Hand-Held Exhaled Nitric Oxide Analyzer
    Ito, Yasunori
    Adachi, Yuichi
    Itazawa, Toshiko
    Okabe, Yoshie
    Adachi, Yoko S.
    Katsumuma, Toshio
    Miyawaki, Toshio
    PEDIATRIC PULMONOLOGY, 2010, 45 (10) : 1005 - 1008
  • [30] Exhaled nitric oxide measurements using a hand-held monitor and a chemiluminescence equipment:: difference is more evident in subjects with higher concentrations
    Llusar, R.
    Lopez, V
    Barato, D.
    Prieto, L.
    ALLERGY, 2008, 63 : 284 - 284