Assessment of exhaled nitric oxide by a new hand-held device

被引:38
|
作者
Antus, Balazs [1 ]
Horvath, Ildiko [2 ]
Barta, Imre [1 ]
机构
[1] Natl Koranyi Inst TB & Pulmonol, Dept Pathophysiol, H-1529 Budapest, Hungary
[2] Semmelweis Univ, Dept Pulmonol, H-1125 Budapest, Hungary
关键词
Exhaled nitric oxide; Logan; NIOX MINO; NObreath; Reproducibility; ASTHMA; ANALYZER;
D O I
10.1016/j.rmed.2010.06.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fractional exhaled nitric oxide (FENO) has been implicated as a pulmonary biomarker. The aim of this study was to compare the performance of a new hand-held device to a standard chemiluminescence analyzer and to another portable device. Methods: FENO levels measured by NObreath (Bedfont) were compared to those of (1) a chemiluminescence detector (Logan, Logan Research) and (2) the electrochemical portable NIOX MINO (Aerocrine) in 18 healthy volunteers on three consecutive occasions: in the morning, 1 h and 24 h later. Results: Comparing FENO levels obtained by NObreath to those by Logan values were similar and a very close linear relationship was found between the two devices (r = 0.923, p < 0.001). The mean inter-device difference in FENO level was -3.45 ppb and the limits of agreement (Bland-Altman test) were -10.98 and 4.08 ppb. In the second series FENO levels obtained by NObreath were found to be slightly higher compared to those of NIOX MINO, but still showed a close correlation (r = 0.681, p < 0.001). The mean inter-device difference in FENO level was 4.36 ppb and the limits of agreement were -7.38 and 16.1 ppb. Analyzing the repeated FENO measurements, the mean coefficient of variation using NObreath tended to be lower than that of NIOX MINO (16.9 vs. 24.7%, p = 0.059), while it was similar as the value obtained with Logan (11.8 vs. 9.0%, p = 0.342). Conclusions: FENO values measured with NObreath are reproducible and in good agreement with those obtained by NIOX MINO and Logan indicating that NObreath is suitable for use in clinical practice. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1377 / 1380
页数:4
相关论文
共 50 条
  • [1] Reliability of a new hand-held device for the measurement of exhaled nitric oxide
    Khalili, B.
    Boggs, P. B.
    Bahna, S. L.
    ALLERGY, 2007, 62 (10) : 1171 - 1174
  • [2] Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
    K Alving
    C Janson
    L Nordvall
    Respiratory Research, 7
  • [3] Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
    Alving, K
    Janson, C
    Nordvall, L
    RESPIRATORY RESEARCH, 2006, 7 (1)
  • [4] Nasal fractional exhaled nitric oxide analysis with a novel hand-held device
    Weschta, Michael
    Deutschle, Tom
    Riechelmann, Herbert
    RHINOLOGY, 2008, 46 (01) : 23 - 27
  • [5] Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications
    Hemmingsson T.
    Linnarsson D.
    Gambert R.
    Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 379 - 387
  • [6] Exhaled nitric oxide measurements: Correction equation to compare hand-held device to stationary analyzer
    Pizzimenti, Stefano
    Bugiani, Massimiliano
    Piccioni, Pavilio
    Heffler, Enrico
    Carosso, Aurelia
    Guida, Giuseppe
    Rolla, Giovanni
    RESPIRATORY MEDICINE, 2008, 102 (09) : 1272 - 1275
  • [7] Novel Hand-Held Device for Exhaled Nitric Oxide-Analysis in Research and Clinical Applications
    Tryggve Hemmingsson
    Dag Linnarsson
    Rudolf Gambert
    Journal of Clinical Monitoring and Computing, 2005, 19 (6) : 463 - 464
  • [8] Validation of a hand-held exhaled nitric oxide analyzer for use in children
    McGill, Claire
    Malik, Gulshan
    Turner, Stephen W.
    PEDIATRIC PULMONOLOGY, 2006, 41 (11) : 1053 - 1057
  • [9] The clinical usefulness of a new hand-held device for fractional exhaled nitric oxide measurement, NIOX VERO®, for diagnosing the etiology of cough
    Hanibuchi, Masaki
    Saijo, Atsuro
    Mitsuhashi, Atsushi
    Takeji, Takashi
    Kitagawa, Tetsuya
    JOURNAL OF MEDICAL INVESTIGATION, 2020, 67 (3-4): : 265 - 270
  • [10] Usability of a hand-held device to determine nasal nitric oxide in clinical routine
    Jung, Andreas
    Bigger, Michael
    Bieli, Christian
    Moller, Alexander
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46