Retrofit of R-410A in Air to Water Heat Pumps: Test of Two Low GWP Candidates

被引:0
|
作者
Zoughaib, Assaad [1 ]
Besbes, Karim [2 ]
机构
[1] Mines ParisTech, Ctr Energy Efficiency Syst CES, Paris, France
[2] CES, Paris, France
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an experimental evaluation of two low GWP refrigerants candidates for the replacement of R-410A in an "air to water" heat pump. The baseline is evaluated following the ANSI/AHRI Standard 551/591. For both low GWP candidates (ARM-70 alpha and DR-5), tests are performed following the same standard for three refrigerant charges. Both heat capacity and coefficient of performance are compared for the baseline and the tests with the low GWP refrigerants. The results show that for the best refrigerant charge, both heat capacity and COP are improved by 5 to 10%. The best refrigerant charge is found for both replacement candidates.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates
    Shen, Bo
    Ally, Moonis R.
    ENERGIES, 2020, 13 (21)
  • [42] Energetic and Exergetic Analysis of Low Global Warming Potential Refrigerants as Substitutes for R410A in Ground Source Heat Pumps
    Bobbo, Sergio
    Fedele, Laura
    Curcio, Marco
    Bet, Anna
    De Carli, Michele
    Emmi, Giuseppe
    Poletto, Fabio
    Tarabotti, Andrea
    Mendrinos, Dimitris
    Mezzasalma, Giulia
    Bernardi, Adriana
    ENERGIES, 2019, 12 (18)
  • [43] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    International Journal of Refrigeration, 2022, 135 : 139 - 147
  • [44] Energetic Analysis of Low Global Warming Potential Refrigerants as Substitutes for R410A and R134a in Ground-Source Heat Pumps
    Fedele, Laura
    Bobbo, Sergio
    Menegazzo, Davide
    De Carli, Michele
    Carnieletto, Laura
    Poletto, Fabio
    Tarabotti, Andrea
    Mendrinos, Dimitris
    Mezzasalma, Giulia
    Bernardi, Adriana
    ENERGIES, 2023, 16 (09)
  • [45] Drop-in analysis of R450A and R513A as low-GWP alternatives to R134a in a water-to-water heat pump
    Molinaroli, Luca
    Lucchini, Andrea
    Colombo, Luigi Pietro Maria
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 135 : 139 - 147
  • [46] Field Test of Air-to-Water Absorption Heat Pumps for Single-Family Homes.
    Heimbach, Paul
    Gaswaerme International, 1988, 37 (04): : 228 - 230
  • [47] Performance comparison among two-phase, liquid, and vapor injection heat pumps with a scroll compressor using R410A
    Kim, Dongwoo
    Jeon, Yongseok
    Jang, Dong Soo
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2018, 137 : 193 - 202
  • [48] R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 348 - 365
  • [49] Comparisons of two-phase condensation and single-phase heat transfer and frictional pressure drop characteristics and energy-saving performance analysis of R-32 and R-410A in plate heat exchanger
    Song, Joo Young
    Kim, Dong Ho
    Song, Chan Ho
    Kang, Yong Tae
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 231
  • [50] Air/Water Heat Pumps in Existing Heating and Hot Water Systems for Better Urban Air Quality and Primary Energy Savings: Scenarios of Two Italian Cities
    Carella, Alberta
    Del Ferraro, Luca
    D'Orazio, Annunziata
    ENERGIES, 2023, 16 (01)