Low-Cost Noninvasive Real-Time Imaging for Tubular Continuous-Flow Crystallization

被引:29
|
作者
Jiang, Mo [1 ]
Braatz, Richard D. [1 ]
机构
[1] MIT, Dept Chem Engn, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
Continuous crystallization; Imaging technology; Inline monitoring; Multiphase flow; Tubular crystallizer; CONTINUOUS MANUFACTURING SYMPOSIUM; PARTICLE-SIZE DISTRIBUTIONS; SHAPE; SPECTROSCOPY; ANTISOLVENT; MICROSCOPY;
D O I
10.1002/ceat.201600276
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A key design limitation to the effective monitoring and control of continuous crystallization processes is the ability to characterize crystals in real time. A low-cost system composed of a basic stereomicroscope and video camera for the in situ imaging of sub-millimeter crystals through curved walls of millifluidic tubular crystallizers is described. Real-time videos taken for millimeter-size slurry slugs are used to guide the experimental design for a recently developed multiphase-flow crystallization process, including the improvement of the slug aspect ratio, visualization of crystal shapes, and observation of the extent of aggregation. Design considerations are also discussed for the use of multiple stereomicroscopes in other continuous-flow tubular experiments.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [31] LOW-COST REAL-TIME DOPPLER FREQUENCY-ANALYSIS
    BLACKWELL, DE
    MCKINNEY, WM
    NUNN, C
    HIRSCH, G
    SACKLER, JP
    MEDICAL ULTRASOUND, 1984, 8 (01) : 23 - 29
  • [32] Low-Cost, Real-Time Obstacle Avoidance for Mobile Robots
    Ricardo, Shawn
    Bein, Doina
    Panagadan, Anand
    2017 IEEE 7TH ANNUAL COMPUTING AND COMMUNICATION WORKSHOP AND CONFERENCE IEEE CCWC-2017, 2017,
  • [33] Development of a Portable Low-cost Real-time PCR System
    Chong, K. S.
    Gan, K. B.
    Then, Sue-Mian.
    2017 INTERNATIONAL CONFERENCE ON ROBOTICS, AUTOMATION AND SCIENCES (ICORAS), 2017,
  • [34] Low-cost noninvasive continuous blood pressure monitor
    de Lorena A.E.S.
    de Lima R.A.
    Malagón L.A.G.
    Research on Biomedical Engineering, 2022, 38 (02) : 559 - 570
  • [35] A portable and low-cost incubator system enabling real-time cell imaging based on a smartphone
    Cetin, Arif Engin
    TURKISH JOURNAL OF PHYSICS, 2023, 47 (05): : 279 - 296
  • [36] Boundary Array Transducer and Beamforming for Low-Cost Real-time 3D Imaging
    Yen, Jesse T.
    Powis, Emily
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [37] DEVELOPMENT OF A SIMPLE, LOW-COST, CONTINUOUS-FLOW SYSTEM FOR THE AUTOMATED RADIOIMMUNOASSAY OF STEROID GLUCURONIDES
    BARNARD, GJ
    COLLINS, WP
    ANNALS OF CLINICAL BIOCHEMISTRY, 1983, 20 (SEP) : 294 - 301
  • [39] A handheld continuous-flow real-time fluorescence qPCR system with a PVC microreactor
    Shi, Bing
    Li, Yuanming
    Wu, Di
    Wu, Wenming
    ANALYST, 2020, 145 (07) : 2767 - 2773
  • [40] A continuous-flow mass biosensor for the real-time dynamic analysis of protease inhibition
    Huang, Yanyan
    Zhang, Qundan
    Liu, Guoquan
    Zhao, Rui
    CHEMICAL COMMUNICATIONS, 2015, 51 (30) : 6601 - 6604