Collarless polished tapered stem - Clinical and radiological results at a minimum of ten years' follow-up

被引:46
|
作者
Yates, P. J. [1 ]
Burston, B. J. [1 ]
Whitley, E. [1 ]
Bannister, G. C. [1 ]
机构
[1] Avon Orthopaed Ctr, Bristol, Avon, England
来源
关键词
D O I
10.1302/0301-620X.90B1.19546
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [41] Clinical and radiological results of high offset tri-lock bone preservation stem in unilateral primary total hip arthroplasty at a minimum follow-up of 3 years
    Peng, Linbo
    Ma, Jun
    Zeng, Yi
    Wu, Yuangang
    Si, Haibo
    Shen, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [42] Results of the 4D study: ten years of follow-up?
    Christoph Wanner
    Kai-Renke Schmidt
    Vera Krane
    Clinical and Experimental Nephrology, 2014, 18 : 274 - 277
  • [43] A ten years follow-up on psychoactive tryptamines deliverance and results of analysis
    Palma Conesa, A. J.
    Grifell, M.
    Quintana, P.
    Ventura, M.
    Fornis, I.
    Galindo, L.
    Gil, C.
    Fonseca, M. F.
    Farre, M.
    Torrens, M.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2016, 26 : S706 - S707
  • [44] Results of the 4D study: ten years of follow-up?
    Wanner, Christoph
    Schmidt, Kai-Renke
    Krane, Vera
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2014, 18 (02) : 274 - 277
  • [45] Intermediate clinical and radiological results of cervical TDR (Mobi-C®) with up to 2 years of follow-up
    Beaurain, J.
    Bernard, P.
    Dufour, T.
    Fuentes, J. M.
    Hovorka, I.
    Huppert, J.
    Steib, J. P.
    Vital, J. M.
    Aubourg, L.
    Vila, T.
    EUROPEAN SPINE JOURNAL, 2009, 18 (06) : 841 - 850
  • [46] Intermediate clinical and radiological results of cervical TDR (Mobi-C®) with up to 2 years of follow-up
    J. Beaurain
    P. Bernard
    T. Dufour
    J. M. Fuentes
    I. Hovorka
    J. Huppert
    J. P. Steib
    J. M. Vital
    L. Aubourg
    T. Vila
    European Spine Journal, 2009, 18 : 841 - 850
  • [47] Clinical Results of Arthroscopic Resection of Dorsal Wrist Ganglion with a Minimum of 3 Years Follow-up
    Saremi, Hossein
    Bolbanabad, Mohammad Mohammadi
    Abdollahian, Amir Reza
    Mohammadi, Younes
    JOURNAL OF WRIST SURGERY, 2023, 12 (01) : 52 - 55
  • [48] Arthroscopic Bankart Suture-Anchor Repair Radiological and Clinical Outcome at Minimum 10 Years of Follow-up
    Castagna, Alessandro
    Markopoulos, Nikolaos
    Conti, Marco
    Delle Rose, Giacomo
    Papadakou, Eugenia
    Garofalo, Raffaele
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (10): : 2012 - 2016
  • [49] Ten years' minimum follow-up with the ileal continent catheterizable reservoir: A test of time
    Macedo, Antonio, Jr.
    Damazio, Eulalio
    Bacelar, Herick
    Rondon, Atila
    Ottoni, Sergio
    Liguori, Riberto
    Garrone, Gilmar
    Leslie, Bruno
    Ortiz, Valdemar
    JOURNAL OF PEDIATRIC UROLOGY, 2013, 9 (03) : 272 - 277
  • [50] Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up
    Scott, Trevor
    Salvatore, Anthony
    Woo, Pauline
    Lee, Yuo-yu
    Salvati, Eduardo A.
    Della Valle, Alejandro Gonzalez
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1120 - 1125